Hash digital PH/ORP differential electrode DPD1R1 DRD1R5
The characteristics and indicators of digital pHDTM differential pH/ORP sensor and non digital differential electrode are the same
Equipped with built-in digital electrodes and a 10 meter cable, it can be directly connected to the SC200 (digital) controller.
Hash digital PH/ORP differential electrode DPD1R1 DRD1R5
order No |
Measurement content |
sensor type |
BODY MATERIAL |
sensor type |
Withstand temperature |
DPD1R1 |
pH |
Flexible style |
Ryton |
General glass |
70℃ |
DPS1 |
pH |
Immersion type |
stainless steel |
General glass |
60℃ |
DRD1P5 |
ORP |
Flexible style |
PEEK |
Platinum electrode |
70℃ |
DRD1P6 |
ORP |
Flexible style |
PEEK |
Gold electrode |
70℃ |
DRD1R5 |
ORP |
Flexible style |
Ryton |
Platinum electrode |
70℃ |
DRD1R6 |
ORP |
Flexible style |
Ryton |
Gold electrode |
70℃ |
DRS5 |
ORP |
Immersion type |
stainless steel |
Platinum electrode |
60℃ |
Digital adapter
6120500 Connect the analog pHDTM sensor to the Hash Company controller using a digital adapter
The characteristics and indicators of digital composite pH/ORP sensors and non digital composite electrodes are the same
All PC SC and RC SC 3/4-inch composite sensors come with a matching integrated 4.5-meter sensor cable, digital adapter, and 1-meter extension cable.
order No | Measurement content | sensor type | BODY MATERIAL | sensor type | temperature compensation | Replace non digital sensors |
DPC1R1A | pH | Flexible style | Ryton | General glass | Pt1000 | PC1R1A |
DPC1R3A | pH | Flexible style | Ryton | Hydrofluoric acid resistant glass | Pt1000 | PC1R3A |
DPC2K1A | pH | plug-in | PVDF | General glass | Pt1000 | PC2K1A |
DPC3K2A | pH | Hygienic | 316SS/PVDF | General glass | Pt1000 | PC3K2A |
DRC1R5N | ORP | Flexible style | Ryton | Platinum electrode | without | RC1R5N |
DRC2K5N | ORP | plug-in | PVDF | Platinum electrode | without | RC2K5N |
Digital adapter
6120600 Use a digital adapter to connect the analog PC/RC sensor to the Hash company's sc200 (digital) or sc1000 controller
The characteristics and indicators of digital pHDTM differential pH/ORP sensor and non digital differential electrode are the same
Equipped with built-in digital electrodes and a 10 meter cable, it can be directly connected to the SC200 (digital) controller.
order No | Measurement content | sensor type | BODY MATERIAL | sensor type | Withstand temperature |
DPD1P1 | pH | Flexible style | PEEK | General glass | 70℃ |
DPD1P3 | pH | Flexible style | PEEK | Hydrofluoric acid resistant glass | 70℃ |
DPD2P1 | pH | plug-in | PEEK | General glass | 70℃ |
DPD3P1 | pH | Hygienic | PEEK | General glass | 70℃ |
DPD1R1 | pH | Flexible style | Ryton | General glass | 70℃ |
DPS1 | pH | Immersion type | stainless steel | General glass | 60℃ |
DRD1P5 | ORP | Flexible style | PEEK | Platinum electrode | 70℃ |
DRD1P6 | ORP | Flexible style | PEEK | Gold electrode | 70℃ |
DRD1R5 | ORP | Flexible style | Ryton | Platinum electrode | 70℃ |
DRD1R6 | ORP | Flexible style | Ryton | Gold electrode | 70℃ |
DRS5 | ORP | Immersion type | stainless steel | Platinum electrode | 60℃ |