Xi'an Huaerwei Instrument Co., Ltd
Home>Products>HW1151、 3851 differential pressure transmitter
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13909219277
  • Address
    No. 76, North Exit of Labor Road, Xi'an City
Contact Now
HW1151、 3851 differential pressure transmitter
Differential pressure transmitters are mainly used to measure the differential pressure, pressure, liquid level, and density of liquids, gases, or vap
Product details

purpose

Differential pressure transmitters are mainly used to measure the differential pressure, pressure, liquid level, and density of liquids, gases, or vapors, and then convert them into 4-20mA DC signal outputs.
Differential pressure transmitters mainly include three types: DP type (base type), HP type (high static pressure), and DR type (micro differential pressure). The above three types of transmitters can be combined with an intelligent amplifier board to form an intelligent differential pressure transmitter, which can communicate with each other through a handheld device that complies with the HART protocol for setting and monitoring. .

The DR type micro differential pressure transmitter can convert small differential pressure into 4-20mA DC signal output. It adopts a specially designed amplification circuit board and a special temperature compensation process, with stable and reliable performance. It is an ideal product for detecting primary and secondary air flow and airflow loss in furnace combustion chamber micro pressure.
DP √△ P type flow transmitter is designed to receive differential pressure signals from throttling components, which are converted into 4-20mA DC signals proportional to the flow rate through a "J" type electronic circuit board with square root function This product uses electronic switch components to switch the relationship between the output current below 20% and the output differential pressure to linear, reducing the instability of the output current of the flow transmitter during the initial working stage. However, below 50% of the output current, due to the higher conversion sensitivity of the flow transmitter compared to differential pressure transmitters of the same specification, its stability is still slightly inferior to differential pressure transmitters.

Model Selection Table

HW3851/1151DP
differential pressure transmitter
code
Range KPa
3
0-0.6~6KPa
4
0-4~40KPa
5
0-40~250KPa
6
0-0.16~1.0MPa
7
0-0.4~2.5MPa
8
0-1.6~10.0MPa
code
output
E
Non intelligent type (4-20mA output)
S
Intelligent (HART protocol)
J
Intelligent square opening type
code
Structural materials
Flanges and fittings
Exhaust/Drain Valve
Isolation Diaphragm
Fill with liquid
22
316 stainless steel
316 stainless steel
316 stainless steel
silicone oil
23
316 stainless steel
316 stainless steel
Hastelloy C
24
316 stainless steel
316 stainless steel
Monel
25
316 stainless steel
316 stainless steel
tantalum
33
Hastelloy C
Hastelloy C
Hastelloy C
35
Hastelloy C
Hastelloy C
tantalum
44
Monel
Monel
Monel
code
Static pressure MPa
B-
4
C-
10
code
additional function
M1
0-100% linear indicator table
M2
LED digital display table
M3
LCD display
B1
Pipe bending installation plate
B2
Plate bending installation plate
B3
Pipe installation safety installation board
C0
1/2-14NPT taper pipe internal thread joint
C1
1/2-14NPT pressure joint rear welded pressure pipe with a diameter of 14
C2
T-shaped threaded joint M20 × 1.5
d
Explosion proof type d Ⅱ BT4
i
Intrinsic safety type ia Ⅱ CT6
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!