As an automatic sampler manufacturer in the industry, HTA in Italy continuously launches new products to meet users' requirements for chromatographic analysis accuracy and automation. HT280T is a multifunctional automatic sampler with the following analytical techniques, capable of performing a range of analytical tasks and seamlessly compatible with any brand of GC and GC/MS:
★ Automatic liquid sample injection
★ Automatic injection of headspace samples
★ SPME solid-phase microextraction automatic injection
★ SPE solid-phase extraction automatic injection
★ Sample pre-processing automation
HT280T automatic samplerMain features:
Heated airtight needle injection ensures high-sensitivity analysis and zero cross contamination
Not occupying the injection port, compatible with manual injection
Overlapping heating improves analysis efficiency
HT280T automatic sampler,Automatic liquid injection:
Multiple programmable precision needle insertion methods
Use four different solvents for cleaning to prevent cross contamination
Dual injection mode, supporting efficient analysis
Automatically add internal standard substances
Sample pretreatment automation: liquid-liquid extraction/solid-phase extraction/
Automatic derivation, dilution, mixing, and distribution of samples
SPMEFully automatic solid-phase microextraction
Solvent free extraction method
Headspace extraction, immersion extraction, and automatic derivation of extraction heads
The extraction head is automatically cleaned to avoid cross contamination
During the extraction process, the heating box is turned off to ensure a constant temperature and better extraction efficiency
Special protection mechanism for fiber extraction head, more economical consumables, and long service life
Technical specifications:
Headspace mode (performance equivalent to HT200H Headspace Automatic Sample Injector) | Liquid mode (performance equivalent to HT300A liquid automatic sampler) | ||||
Oscillation mode: | Cyclotron oscillation | Injection needle volume: | 1,5,10,25,50,100ul | ||
Heating oscillation box: | Six positions, can be overlapped for heating | Sample tray: | 110 positions, 2/2.5ml liquid bottle | ||
Volume of airtight needle: | 2.5ml | Liquid absorption volume: | Zui small 0.1ul | ||
Sample tray: | 40 positions, 10/20ml headspace bottle | Air volume: | Zui small 0.1ul | ||
Cleaning system: | nitrogen purge | Liquid absorption speed: | 1-100ul/sec | ||
add | Heating box temperature: | 40-150℃ | Injection needle cleaning: | Four solvents and/or sample programming cleaning | |
heat | Thermal equilibrium time setting: | 0-23 hours 59 minutes | Cleaning method for bubbles: | Zui 15 more rapid extractions | |
flat | Step heating time: | 0-9 hours and 59 minutes | advance | Injection speed: | 1-100ul/sec |
Heng | Vibration speed: | 320-720 rpm | appearance | Injection interval time: | 0-99 seconds |
| Vibration cycle off/on: | 0-9.9 minutes |
| Needle insertion depth: | Optimization and adjustment of GC injection port structure |
| Airtight needle heating sleeve: | 40-150℃ | within | Internal standard volume: | Zui small 0.1ul |
take | Pre filled volume: | 0.01ml step | treetop | Air volume: | Zui small 0.1ul |
kind | Extraction: | Zui 15 more times |
| Air gap: | 1 or 2 intervals |
ginseng | Extraction equilibrium delay: | Zui is 60 seconds long | Sample pre-processing automation (optional) | ||
number | Sampling volume: | 0.01-2.5ml/0.01ml step size | Liquid liquid extraction, solid phase extraction, derivatization, dilution, mixing, and distribution | ||
| Sampling speed: | 0.1-100ml/min | software | ||
advance | Sampling frequency (MHE) | Zui 15 more times | HT-Comsoft-A/H/S, Clarity Chromatography Workstation | ||
appearance | Sampling interval time: | 0-99 minutes |
| ||
ginseng | Injection speed: | 0.1-100ml/min | GC&GCMS Compatibility List | ||
number | Injection interval time: | 0-99 seconds | Agilent Agilent | 7890/6890/6820/5890/4890 | |
SPME fully automatic solid-phase microextraction mode |
| MS 5975/5973/5972 | |||
Extraction method: | Headspace/immersion/derivatization | Shimadzu Shimadzu | 2010/2014/14/17A/QP2010 | ||
Sample tray: | 40 people, 10/20ml sample bottle | PE | Autosystem /Claus500/600 | ||
Oscillation mode: | Cyclotron oscillation 320-720rpm | Varian Varian | 3800/3900/3400 | ||
Heating oscillation box: | Six digits (including derivative positions) | Thermo Thermoelectric | Trace/Focus/CE8000 | ||
Heating box temperature: | 40-150℃ | Hitachi/GL Science | G3000/GC353 | ||
Heating box cover: | The extraction process is in a closed state | Other imported GC brands | Dani/Perichrom/SRI/Younglin | ||
Extraction head cleaning: | Injection port or optional cleaning device |
| Grow Mac/Chemito/Donam... | ||
Fiber extraction head protection mechanism: | have | Domestic GC brand | Beifen/Fuli/Shangfen/Tianmei/Chuanyi |
otherHTAMembers of the automatic sampler family:
HT250D | HT200H | HT300A | HT300L | HT400E |
Liquid headspace two in one |
Headspace Autosampler |
Gas phase liquid automatic injection |
HPLC automatic sampler |
SPE automatic sampler |