Shanghai Lunjie Electromechanical Instrument Co., Ltd
Home>Products>HL-600 portable Shore hardness tester
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    13162829387
  • Address
    Room 2303, Guoke Building, Building 1, Lane 1029, Kongjiang Road, Shanghai
Contact Now
HL-600 portable Shore hardness tester
HL-600 portable Shore hardness tester
Product details

HL-600Portable digital displayleeb hardness tester

HL-600Portable digital displayThe Leeb hardness tester is the latest product developed by our company, which includes a built-in printerUSBOutput interface.

■ Directly display Richter, Brinell, Roche, Vickers, Shawtensile strengthWaiting for various hardness values,

HL-600Type is substitutionHL-80HL-200HL-240HL-300HL-800HLN-11ATH110TH-140TH-160Waiting for the ideal cost-effective product of Leeb hardness tester.

Product features:

·According to the principle of Leeb hardness measurement, various metal materials can be tested

·One host can be equipped with7Use different types of impact devices and automatically identify the type of impact device,No need to recalibrate during replacement

·Support 'forged steel'(Steel)”Materials, when usedD/DCWhen testing the "forged steel" specimen with a type of impact device, it can be directly readHBValue, no need for manual table lookup. Pre set upper and lower limits for hardness values, automatic alarm for exceeding the range, convenient for users' needs for batch testing ·Adopting a large screen128×64Graphic dot matrix LCD display, rich and intuitive information

·Full Chinese display, menu style operation, simple and convenient operation, withELBacklit display, convenient for use in low light environments ·Maximum storage capacity500Group (number of impacts)132)Hardness measurement data, each set of data including single measurement value, average value, measurement date, impact direction, frequency, material, hardness system and other information

·The thermal printer is integrated with the instrument, with fast printing speed and the ability to print inspection reports on site. Equipped with software calibration function

·Built in nickel hydrogen rechargeable battery and charger; Can work continuously for no less than150Hour; Equipped with energy-saving functions such as automatic sleep mode and automatic shutdown ·There is a remaining battery indicator icon on the LCD, which can display the remaining battery level in real time; Equipped with charging process indicators, the charging progress can be monitored at any time haveUSBOutput interface, convenient and fast to connect withPCMachine for data exchange. It can be equipped with microcomputer software, which has rich functions such as transmitting measurement results, storing and managing measurement values, statistical analysis of measurement values, printing measurement reports, and batch setting instrument parameters, meeting higher requirements for quality assurance and management.

·The instrument is compact, portable, highly reliable, suitable for harsh operating environments, and resistant to vibration, impact, and electromagnetic interference.

·External dimensions:212mm×80mm×32mm ·Weight:580g

■ Applicable materials:Steel and cast steel, alloy tool steel, stainless steel, gray cast iron, ductile iron, cast aluminum alloy, copper zinc alloy (brass), copper tin alloy (bronze), pure copper forged steel

Main application areas:·Failure analysis of bearings and other components, pressure vessels, steam turbine generators and their equipment

·Heavy workpieces · Installed mechanical or permanently assembled components ·Workpieces with limited experimental space

·Require formal original records of test results and material differentiation in metal material warehouses

·Rapid inspection of multiple measurement points in a large area of large workpieces

■ Technical parameters:

·Measurement range:(170-960)HLD(17-68.5)HRC(13-100)HRB(59-85)HRA

(19-651)HB(80-976)HV(30-100)HS

·Measurement direction: Supports360Omnidirectional and arbitrary direction(Vertical downward, oblique downward, horizontal, oblique upward, vertical upward)

·Hardness standard: LeebHLBu ShiHBLuo'sHRCLuo'sHRBLuo'sHRAVickersHVXiao'sHS

·Indication error: ±4HLD(HLD=760time)

·Show off Display: Dot matrixLCD128×64Graphic dot matrix LCD

·Thermal printer: capable of printing any number of test results to meet on-site needs

·Printing paper width: (57.5±0.5mmPrinting paper roll diameter:30mm

·Working voltage:6VNiMH battery pack

·Charging power supply:9V/500mACharging time2.53.5hour

·Continuous working time: approximately150Hour (without printing or backlight)

·Communication interface standard:USB1.1

Working conditions:Environmental temperature: Operating temperature -10~+50Storage temperature:-30℃~+60

Relative humidity ≤90%; There is no strong vibration, strong magnetic field, corrosive medium, or severe dust in the surrounding environment.

■ Operating instructions:After booting up, it will automatically enter the main display interface:

·Battery level: Display remaining battery level ·Impact direction: Current impact direction

·Average value: appears when the average value is displayed after reaching the set number of impacts

·Hardness system: The hardness system of the current measured value

·Measurement value: current single measurement value (no average prompt), current average value (with average prompt)

·Show off Display: indicates exceeding the conversion or measurement range, indicates falling below the conversion or measurement range

·Materials Material: The currently set material

·Impact frequency: Display the completed impact frequency during measurement, display the set impact frequency when setting the impact frequency with the frequency shortcut key, and display the corresponding number of times for a single measurement value when browsing.

USBData processing software:

·Storage: Store the measured data ·Call out: call out data from the host

·Printing: Print and output data,A4interface ·Over limit: Display of over limit after setting tolerance limit

·Clear: Clear measurement data ·Connection: Set up connection with the host ·Disconnect: Set to disconnect from the host

·Download: Download data locally to achieve massive storage · Settings: Parameter settings · Help: Instant help function

Selection of impact device:

HL-600The standard sensor isDType, suitable for most occasions.
HL-600DC
The type of sensor isDCType, suitable for situations with limited space, such as bucket shaped inner walls or inside assembled machinery.
HL-600D+15
The type of sensor isD+15Type, suitable for use in grooves or concave surfaces.
HL
-600CThe type of sensor isCType, with minimal impact force, suitable for measuring workpieces with high surface quality or thin quenched and hardened layers.
HL-600E
The type of sensor isEType, made of diamond material, suitable for work with extremely high hardness.
HL
-600GThe type of sensor isGType, suitable for casting, forging, and workpieces with rough surfaces.
HL
-600DLThe type of sensor isDLType, suitable for measuring deep grooves, narrow hole bottoms, or tooth surfaces of workpieces.

Various material measurement tables:

material

Hardness system

Impact device

D/DC

D+15

C

G

E

DL

Steel and cast steel

Steel and cast steel

HRC

17.968.5

19.367.9

20.069.5

22.470.7

20.668.2

HRB

59.699.6

47.799.9

37.099.9

HRA

59.185.8

61.788.0

HB

127651

80638

80683

90646

83663

81646

HV

83976

80937

80996

841042

80950

HS

32.299.5

33.399.3

31.8102.1

35.8102.6

30.696.8

Steelforged steel

HB

143650

CWTST

alloy tool steel

HRC

20.467.1

19.868.2

20.768.2

22.670.2

HV

80898

80935

100941

821009

Stainless steel

stainless steel

HRB

46.5101.7

HB

85655

HV

85802

GC. IRON

Grey cast iron

HRC

HB

93334

92326

HV

NCIRON

nodular cast iron

HRC

HB

131387

127364

HV

CALUM

Cast aluminum alloy

HB

19164

23210

32168

HRB

23.884.6

22.785.0

23.885.5

BRASSCopper-Zinc alloys

(Brass)

HB

40173

HRB

13.595.3

BRONZECopper tin alloy (bronze)

HB

60290

COPPERPure copper

HB

45315

Introduction Table of Technical Parameters and Applicability of Irregular Impact Device:

Irregular impact device

DC(D)/DL

D+15

C

G

E

Impact energy

Impact mass

11mJ

5.5g/7.2g

11mJ

7.8g

2.7mJ

3.0g

90mJ

20.0g

11mJ

5.5g

Ball head hardness

Ball head diameter

Ball head material

1600HV

3mm

tungsten carbide

1600HV

3mm

tungsten carbide

1600HV

3mm

tungsten carbide

1600HV

5mm

tungsten carbide

5000HV

3mm

diamond

Diameter of impact device

Length of impact device

Weight of impact device

20mm

86(147)/75mm

50g

20mm

162mm

80g

20mm

141mm

75g

30mm

254mm

250g

20mm

155mm

80g

Maximum hardness of the specimen

940HV

940HV

1000HV

650HB

1200HV

Average surface roughness of the specimenRa:

1.6μm

1.6μm

0.4μm

6.3μm

1.6μm

Minimum weight of test piece

Can be directly measured and requires stable support

Need for dense coupling

>5kg

25kg

0.052kg

>5kg

25kg

0.052kg

>1.5kg

0.51.5kg

0.020.5kg

>15kg

515kg

0.55kg

>5kg

25kg

0.052kg

Minimum thickness of test piece

Minimum depth of dense coupled hardening layer

5mm

0.8mm

5mm

0.8mm

1mm

0.2mm

10mm

1.2mm

5mm

0.8mm

Ball indentation size

hardness300HVtime

Indentation diameter

Indentation depth

0.54mm

24μm

0.54mm

24μm

0.38mm

12μm

1.03mm

53μm

0.54mm

24μm

hardness600HVtime

Indentation diameter

Indentation depth

0.54mm

17μm

0.54mm

17μm

0.32mm

8μm

0.90mm

41μm

0.54mm

17μm

hardness800HVtime

Indentation diameter

Indentation depth

0.35mm

10μm

0.35mm

10μm

0.35mm

7μm

--

--

0.35mm

10μm

Scope of application of impact device

DType used for routine measurementDCType measuring hole or cylindrical tubeDLMeasuring slender narrow slots or holes

■ Standard configuration:

Instrument host

1tower

printing paper

1roll up

DType impact device

1only

Delivery Attached Documentation

1share

Standard Leeb hardness block

1piece

ABSInstrument box

1only

nylon brushA

1only

Software CD

1cover

Small support ring

1only

Communication cables

1strip

Power adapter (charger)

1only

Accompanying documents

1cover

■ User selection:

Irregular impact device

7species

Impact ball head

2species

Irregular support ring

12individual

Replace the impact ball head tool

1pay

■ After sales service commitment:

1. 3Free replacement for quality issues within one month.

2. Free two-year warranty (excluding impact device), lifetime maintenance

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!