HK-5401Hydrogen Conductivity Electrodeionization(EDI)ModuletakeElectrodialysis technology and ion exchange technology are ingeniously integrated. Through the selective permeation of ion exchange membranes and the exchange of ions in the sample water by exchange resins, the directional migration of ions in the sample water is achieved under the action of an electric field, thereby achieving the removal of cations in the sample water.
Application scenarios:
Can replace traditional resin based cation exchange equipment, suitable for steam water quality hydrogen conductivity, deaerated hydrogen conductivity, computational type in thermal power, petroleum, petrochemical, steel and other fieldspHMonitor for waiting indicators.
1unwantedRegularly replace resin or perform resin maintenanceChemical regeneration;
2. The maintenance workload during operation is small;
3. Water outletStable water quality, low operating costs, and no sewage discharge;
4. Metal body, compact and beautiful in appearance, quick plug connector, easy to install;
5. Power supply, operation, and fault indicator lights make the current operating status of the module clear at a glance;
6. Equipped with intelligent flow judgment to achieve automatic power-off protection after interruption;
7. It has digital signal input and output functions.
Specification and model |
HK-5401 |
Supply electric |
AC220VorDC24V |
Gong Gong rate |
20W |
Use traffic |
6-18L/h |
Use pressure |
≤0.2MPa |
Signal output: |
RS485 |
Response time |
≤5min |
Waterproof grade |
IP65 |
Installation method |
Wall mounted |
Ruler inch |
200×322×100mm(Length x Height x Thickness) |
Heavy amount |
About5kg |