HK-358 Steam Sodium Ion MonitoruseExquisite structure, disc installation, all aluminum frame box, strong anti-interference ability, fast response, accurate measurement, easy operation and other characteristics. It is mainly used for continuous monitoring of sodium ion content in power plant main steam pipes, saturated steam, etc. It can be widely used in industries such as power and petrochemicals.
Advanced embedded microcontroller technology, surface mount technology, and integrated design have improved cost-effectiveness and reliability
High quality imported electrodes, effective alkalization method, and unique automatic stability judgment function ensure the stability and reliability of measurement
Simultaneous display of multiple parameters, rich content, easy to understand
◆ Automatic or manual temperature compensation
◆ Two way isolation current output and two way alarm signal
◆ With large capacity historical data storage and historical curve query function
Electronic unit |
|
display |
192X64Dot matrix LCD, can choose to display Chinese or English |
range |
(0.00~9.36)pNa,0.01μg/L~23.0g/L,(-1000~+1000)mV |
Resolution |
0.01pNa,0.01μg/L,0.1mV |
Basic error |
±0.02pNa |
stability |
±0.02pNa/24h |
Current output |
(0~10)mA、(0~20)mAor(4~20)mA(Two way isolated output) |
Output accuracy |
±1%FS |
Output load resistance |
800Ω |
Power supply |
AC(100~240)V, frequency(50~60)Hz |
Power consumption |
≤8W |
Alarm output |
Two channel alarm output, programmable alarm content |
Automatic data storage |
Can be set to automatically record historical data, events, and calibration records |
complete machine |
|
range |
(1.00~8.00)pNa,0.23μg/L~2300mg/L |
Resolution |
0.01pNaor0.01μg/L |
Basic error |
±0.05pNaor±5μg/LTake the maximum value(In calibrating the temperature±10Within ℃) |
response time(T90) |
2min(25℃ |
) |
Temperature sensor |
Pt1000 |
temperature range(0.00~99.9) |
℃ |
Temperature measurement accuracy±0.5 |
℃ |
0.1Temperature resolution |
℃ |
Temperature compensation range(0.1~60.0)℃(Manual or automatic |
) |
calibration method |
Sample calibration, standard solution calibration |
Sample requirementsTemperature:(5~50) ℃Pressure: (50~300)kPaTraffic: (6~20)L/hThe water sample is allowed to contain solid components≤5μm(No gelatinous substances or grease are allowed |
) |
environment conditionEnvironmental temperature:(5~45) ℃Relative temperature:≤90%(non-condensing )Storage and transportation temperature:(-20~55)℃(0Without electrodes, the electrodes should be higher than℃ |
) |
External dimensions450mmx690mmx190mm(wideXhighXdeep |
) |
Hole size410mmx |
645mm |
weight |
20kg
One online sodium measuring electrode
One online sodium reference electrode
1 bottle of sodium standard solution
1 bottle of reference electrode filling solution
1 bottle of electrode activation solution
● One disposable syringe