Suitable for rapid measurement of 16 indicators including acidity, pH mV conversion, oxidation-reduction, conductivity, total solid solubility, resistivity, turbidity, dissolved oxygen, saturated dissolved oxygen, salinity, seawater specific gravity, atmospheric pressure, ammonia nitrogen, chloride, nitrate, temperature, etc,
Unique GPS global positioning system and T.I.S. electronic tag system, large capacity data storage, chart curve display, USB data interface, automatic endpoint locking
Product Overview:
•New ergonomic design, IP67 waterproof and anti slip design, oversized background light, chart display function, excellent cost-effectiveness;
•GPS global positioning system, accurate positioning and measurement coordinates, innovative map preview function, effectively improving data management;
•Multi parameter integrated electrode design enables rapid simultaneous measurement of 16 important water quality indicators, full screen display, and clear visibility;
•Unique fast calibration function, automatic error diagnosis function, automatic recognition of range and electrode type, easy replacement of measurements;
•Ionic selective electrode method for measuring ammonia nitrogen, chloride and nitrate, in compliance with ISO 7027 standard for turbidity determination, with built-in DO compensation pressure device;
•Powerful GLP function, large capacity data storage function, USB data interface, professional data analysis and management software;
•Unique Fast Tracker ™ T. I.S. electronic tag system, with no omissions in data information and the function of displaying data curves in screen charts;
•The electrode is designed with a stainless steel protective shell and meets IP68 waterproof standards, suitable for measuring harsh environments such as pipelines or deep wells;
•Excellent anti electromagnetic signal interference, automatic endpoint locking, ensuring measurement reliability, accuracy, and adaptability to a wide range of fields;
• InsidePlacing rechargeable batteries, power adapters, or car chargers is an ideal choice for mobile monitoring and accurate laboratory analysis.
Multiple electrode configurations, suitable for different measurement requirementsIntelligent electrodes with built-in microprocessors and signal amplifiers are used, and electronic sensors are installed in the electrode holder to automatically identify the type of electrode, making it convenient and quick to replace on site. The electrode is connected to the host through a waterproof cable with a DIN interface. The length of the electrode cable is 4 meters, 10 meters, 20 meters, and 50 meters, suitable for different measurement environments and requirements.T. I.S Electronic Tag Automatic Recognition Data System - Fast TrackerTM (T.I.S)HANNA’s iButton ® The electronic tag recognition system uses a unique ID code to store data from different measurement points. When it is connected to the instrument, it will display measurement data, sampling site ID, date, and time. At the same time, data information can also be transmitted to a PC, Fast Tracker ™ It is a supplement and improvement to the GPS tracking and measurement management function.GPS Global Positioning System data collection, measurement, and trackingGPS Global Positioning System&Fast Tracker ™, Built in 12 channel receiver and antenna, easy to obtain location sampling and measurement point geographic coordinates, with positioning accuracy within 30 meters; Display the GPS sampling coordinates of 10 measurement items on the screen and store them together with the measurement data (display the last positioning coordinates, indicating no GPS signal); GPS information can be transmitted to a computer through data management and analysis software, achieving functions similar to Google ™ Display the specific location of the sampling on the map to improve the completeness and accuracy of the measurement data
Technical parameters:
acidityPH and pH/mVconvertTECHNICAL INDEX
measuring range:0.00 to 14.00pH/±600.0 mV
Resolution:0.01 pH/0.1 mV;Measurement accuracy:±0.02 pH/±0.5mV
Calibration mode:
Up to threedropAutomatic recognition calibration and oneA custom calibration,Built in fiveA standard calibration point
(4.01、6.86、7.01、9.18、10.01pH)
redoxORP/mVTECHNICAL INDEX
measuring range:±2000.0 mVResolution:0.1 mV;Measurement accuracy:±1.0mVCalibration mode:single-pointCustom calibration
ISEion concentrationTECHNICAL INDEX
Ammonia nitrogen measurement range:0.02 to 200 mg/L(ppm)as NChloride measurement range:0.6 to 200 mg/L(ppm)Measurement range of nitrate (nitrogen):0.62 to 200 mg/L(ppm)as NResolution:0.01 mg/L(≤1 mg/L)、0.1 mg/L(>1 mg/L)measurement accuracy:reading±5%perhaps2 mg/L,Take the largest oneCalibration mode:1. 2Automatic point recognition calibration, built-in standard calibration points:10 mg/L(ppm)、 one hundredmg/L(ppm)
conductivityECTECHNICAL INDEX
0.0 to 200.0 mS/cm(No temperature compensation, actual conductivity:0.0 to 400.0 mS/cm)
0 to 9999µS/cm、 10.00 to 99.99 mS/cm、 100.0 to 400.0mS/cm
resolution:1 µ S/cm0.01mS/cm、 01mS/cm
measurement accuracy:reading±1%perhaps1 µS/cm,Take the largest one
Calibration Mode:Automatic recognition of single point calibration, user-defined calibration,Built in sixA conductivity standard calibration point
84µS/cm、 one thousand four hundred and thirteenµS/cm、 fivemS/cm、 twelve point eight eightmS/cm、 eightymS/cm、 one hundred and eleven point eightmS/cm
resistivityTECHNICAL INDEX
0 to 999999 Ω•cm、0 to 1000.0 kΩ•cm、0 to 1.000.0 MΩ•cm
TDSTDSTECHNICAL INDEX
0 to 400000mg/L(ppm)(The maximum value depends onTDSconversion coefficient)
0 to 9999mg/L(ppm)、10.00to 99.99g/L(ppt)、 one hundredto 400.0g/L(ppt)
analysisDegree:1 mg/L(ppm)、0.01 g/L(ppt)、 01 g/L(ppt)
measurement accuracy:reading±1%perhaps1 mg/L(ppm),Take the largest one
solidbordersalinityTECHNICAL INDEX
measuring range:0.00 to 70.00 PUS;Resolution:0.01 PUS
Measurement accuracy:reading±2%perhaps0.01 PUS,Take the largest one
Calibration mode: single pointCustom calibration
Specific gravity of seawaterTECHNICAL INDEX
measuring range:0.0 to 50.0 σt、 σ0、 σ15;
Resolution:0.1 σt、 σ0、 σ15;Measurement accuracy:±1σt、 σ0、 σ15
Calibration mode: Based on conductivity or salinity calibration
Turbidity (compliant)ISO7027standard)TECHNICAL INDEX
measuring range:0.0 to 99.9 FNU、100 to 1000 FNU
Resolution:0.1 FNU、1 FNU
Measurement accuracy:reading±2%perhaps0.3 FNU,Take the largest one
Calibration mode: automatic recognition andCustom calibration, built-in standard calibration points:0, 20, 200FNU
Dissolved oxygen&saturated dissolved oxygenTECHNICAL INDEX
measuring range:0.00 to 50.00mg/L(ppm)、0.0 to 500.0 %
analysisDegree:0.01 mg/L(ppm)、0.1 %
measurement accuracy:
≤30.00mg/L:reading±1.5%Or 010 mg/L(ppm),Take the largest one,>30.00mg/L:reading±3%≤300.0%:reading±1.5%perhaps1.0 %,Take the largest one,>300.0%:reading±3%Calibration mode: single point or double point calibration automatic calibration, zero point or air automatic calibration100%calibration
Atmospheric pressureTECHNICAL INDEX
450 to 850mm Hg、17.72 to 33.46in Hg、600.0 to 1133.2 mbar
8.702 to 16.436psi、0.5921 to 1.1184atm、60.00 to 113.32 kPa
analysisDegree:0.1 mm Hg、0.01 in Hg、0.1mbar、0.001psi、0.0001atm、0.01kPa
measurement accuracy:±3mmHg @ ±15°C
Calibration mode: single pointCustom calibration
Temperature technical indicators
-5.00 to 55.00 ° C, 23. 00 to 131.00 ° F, 268.15to 328.15KResolution:0.01 ° C, 0.01 ° F, 0.01K,Measurement accuracy:± 0.15°C、 ± 0.27°F、 ± 0.15KCalibration mode: single pointCustom calibration
Other technical indicators
GPSPositioning function:12Satellite search and positioning,30riceWithin the positioning range
Temperature compensation:automatic temperature compensation,-5.00 to 55.00 ° C, 23.00 to 131.00°F
Data storage:44000Storage of measurement data, recording interval setting:1Seconds to3Hour,USBdata interface
Waterproof standard: Host:IP67Specialized multi parameter electrode:IP68
Other functions:FastTracker ™ TAG ID
Power mode:1.5V×4AAABattery or1.2V×4Rechargeable battery,AC230V/12DCThe power adapter
Usage environment:0 to 50°C(32 to 122°F),RH max 100% Size and weight:Host size:221x 115x 55mmWeight of the host:750g
Standard configuration:
HI9829GT-04
Built in GPS host, HI7609829/04 customized standard type with built-in pH EC/turbidity DO multi parameter electrode, 4 meters long, dissolved oxygen filling solution, specification: 30ml, HI76409A/P dissolved oxygen membrane (5 pieces), HI9828-0 rapid comprehensive calibration solution, HI9829-60 customized turbidity standard solution set, HI7698290 rapid calibration cup, data management software set, other accessories, Chinese and English user manual, HI721029 customized special instrument carrying case