Beijing Aerospace Topology High tech Co., Ltd
Home>Products>HG-3528 Data Acquisition Fault Diagnosis System
HG-3528 Data Acquisition Fault Diagnosis System
HG-3528 Data Acquisition Fault Diagnosis System
Product details

Overview
The HG-3500 series data acquisition fault diagnosis system has multi parameter on-site acquisition, which includes both equipment status data acquisition function and waveform data acquisition function. The collection method is flexible, fully displayed in Chinese, and easy to operate. The supporting software provides commonly used time-domain, frequency-domain analysis, and state trend analysis functions to help us predict equipment status and diagnose faults. The self diagnostic software for rotating machinery provides expert opinions on common equipment faults; The diagnostic expert system for AC induction motors can diagnose AC asynchronous motors, etc; Provides comprehensive enterprise equipment management functions and can generate various reports, making it a powerful assistant for enterprise equipment fault diagnosis and management

The system supports networked data analysis and management functions; The collector software is divided into a standalone version and a network version.

P11-1.jpgP11-2.jpgP11-3.jpg

Online version software

Optional software
Automatic diagnosis software package for rotating machinery faults

■ Communication asynchronous motor fault diagnosis software package

technical indicators
■ Vibration parameters:
Measurement range: Acceleration: 0.1~199.9m/s2 (0~p) (5Hz/10Hz~10KHz)
Speed: 0.01~19.99cm/s (rms) (5Hz/10Hz~1KHz)
Displacement: 0.001~1.999mm (p~p) (5Hz/10Hz~1KHz)
Frequency range: Lower limit of frequency: 10Hz (5Hz)
Frequency upper limit: 1KHz or 10KHz
Measurement accuracy: 5% ± 2 words
■ Temperature: Measurement range: 0-150 ℃ Measurement accuracy: 1% ± 1 word
■ Speed: Measurement range: 1~60000 revolutions per minute Measurement accuracy: 1 ‰ ± 1 word
■ Waveform acquisition:
Frequency range: Lower limit of frequency: 10Hz (5Hz)
Frequency upper limit: variable from 100Hz to 10KHz
Group number range: 1-100 Group distance range: continuous to 999.99 seconds
Dynamic range: 72dB
Automatic zoom in: 1, 2, 4, 8, 16, 32, 64, 128 times
Collecting parameters: State parameters (vibration acceleration, displacement, velocity; rotational speed; temperature)
On site acquisition and storage of vibration waveforms and motor current waveforms
Storage space: 128KB (1000 sets of status data, 100 sets of 512 point waveform data)
■ Display: 128 × 64 dot matrix LCD, Chinese character display, with backlight
■ Power supply: Built in rechargeable battery or 9V regulated power supply
■ Volume: 185 × 100 × 45 (mm)


Online inquiry