Support three-phase unbalanced load, three timesstartPeak power, pure sine wave output at power frequency, strong load capacity, easy to handle dynamic impact loads |
The mains power intelligently charges the battery through an inverter, and the charging current can be selected by oneself0-45AThree stage charging: constant current, constant voltage, float charging, extending battery life |
![]() UPS power supply Adopting dual transformation technology and static electronic bypass technology, with zero switching time, to provide stable and high-quality power supply for high demand machinery and equipment that is not affected by power grid fluctuations |
|
Set different working modes for different usage requirements: mains priority, inverter priority, energy-saving mode |
The digital LCD screen intuitively displays various operating states of the inverter. Optional RS232/RS485/mobile app/SNMP/GSM communication software for remote monitoring of inverters |
Battery undervoltage and overvoltage protection, overload power protection, inverter output short circuit protection, high temperature protection function, and alarm function |
![]() |
Priority given to mains electricity When the mains power is normal (within the input voltage range of the machine's mains power), the mains power not only charges the battery, but also outputs stable AC power after being stabilized; When the mains power is abnormal (the mains power exceeds the working range of the machine or is interrupted), the machine switches to battery inverter power supply. |
|
![]() |
Battery priority When the battery is fully charged (i.e. the voltage of a conventional single cell battery is 13.2VDC), even if the mains input is normal, the machine will switch to battery inverter power supply; When the battery voltage is low (i.e. the voltage of a conventional single cell battery is below 11VDC) and the mains input is normal, the machine switches to mains mode for power supply. When the mains and PV are normal, the mains and solar controller charge the battery simultaneously. |
|
![]() |
Power Saving Mode The machine operates in battery inverter mode (ineffective in mains mode). When the load is below 10% of the rated load, the inverter will start and stop at regular intervals to save battery energy (i.e. the machine will intermittently interrupt the inverter output); When the load exceeds 10% of the rated load, the inverter will continue to operate in the inverter state (i.e. the machine will not intermittently interrupt the inverter output). |
Attention: In the mains priority/battery priority mode, when the mains charging current is not set to 0A, the mains can charge the battery; When the charging current of the mains is set to 0A, the mains does not charge the battery, only the solar controller charges the battery.
| Technical Specifications | |||||||||
| Model HDSX | 4KVA | 6KVA | 7KVA | 8KVA | 10KVA | 15KVA | 20KVA | 25KVA | |
| rated power | 3.2KW | 4.8KW | 5.6KW | 6.4KW | 8KW | 12KW | 16KW | 20KW | |
| Peak power (20ms) | 9.6KW | 14.4KW | 16.8KW | 19.2KW | 24KW | 36KW | 48KW | 60KW | |
| starter motor | 3HP | 4HP | 4HP | 4HP | 5HP | 7HP | 10HP | 10HP | |
| Standard battery voltage | 48/96/192VDC | 96/192/384VDC | |||||||
| Machine size (L * W * H mm) | 565*300*775 | 725*365*1010 | |||||||
| Packaging size (L * W * H mm) | 625*360*895 | 785*425*1135 | |||||||
| Net weight (kg) | 65 | 73 | 75 | 80 | 122 | 134 | 160 | 176 | |
| Gross weight (kg) (wooden crate packaging) | 78 | 86 | 88 | 93 | 146 | 158 | 184 | 200 | |
| Technical Specifications | |||||||||
| Model HDSX | 30KVA | 40KVA | 50KVA | 60KVA | 80KVA | 100KVA | 125KVA | 150KVA | |
| rated power | 24KW | 32KW | 40KW | 48KW | 64KW | 80KW | 100KW | 120KW | |
| Peak power (20ms) | 72KW | 96KW | 120KW | 144KW | 192KW | 240KW | 300KW | 360KW | |
| starter motor | 15HP | 15HP | 20HP | 25HP | 30HP | 40HP | 50HP | 60HP | |
| Standard battery voltage | 192/384VDC | 384VDC | |||||||
| Machine size (L * W * H mm) | 715*575*1275 | 925*760*1450 | |||||||
| Packaging size (L * W * H mm) | 775*635*1400 | 990*825*1590 | |||||||
| Net weight (kg) | 257 | 287 | 307 | 337 | 355 | 512 | 552 | 612 | |
| Gross weight (kg) (wooden crate packaging) | 290 | 320 | 340 | 370 | 388 | 552 | 592 | 652 | |
| General Parameters | |||||||||
| input | DC input voltage range | 10.5VDC-15VDC (single battery voltage) | |||||||
| Range of mains input voltage | 380Vac/400Vac±10%(可定制190Vac/200Vac) | ||||||||
| Frequency range of mains power input | 45Hz-65Hz | ||||||||
| Maximum mains charging current | 20A/10A/5A | 20A/10A/5A | 20A/10A/5A | 25A/15A/10A | 25A/15A/10A | 30A/20A/10A | 30A/20A/10A | 45A/30A/15A | |
| 30A/15A | 40A/20A | 45A/25A | 45A/30A | 30A | 45A | 45A | 45A | ||
| Municipal power charging method | Three stage (constant current, constant voltage, float charging) | ||||||||
| Phase system | 3/N/PE | ||||||||
| output | Inverter output efficiency | ≥85% | |||||||
| Inverter output voltage | 380Vac/400Vac±10%(可定制190Vac/200Vac) | ||||||||
| Inverter output frequency | 50/60Hz ±1% | ||||||||
| Inverted output waveform | pure sine wave | ||||||||
| Inverted output waveform degree of distortion |
Linear load ≤ 3% | ||||||||
| Efficiency of mains power output | >99% | ||||||||
| Mains output voltage | Follow the mains input | ||||||||
| Mains output frequency | Follow the mains input | ||||||||
| Battery mode no-load loss | ≤ 1% rated power | ||||||||
| 市电模式空载损耗 | ≤ 2% rated power (mains charger not working) | ||||||||
| Energy saving mode no-load loss | ≤10W | ||||||||
| Phase system | 3/N/PE | ||||||||
| battery type (Optional) |
U0: Gel U.S.A | Average charging voltage: 14V; Floating charging voltage: 13.7V (voltage of a single battery) | |||||||
| U1: A.G.M.1 | Average charging voltage: 14.1V; Floating charging voltage: 13.4V (voltage of a single battery) | ||||||||
| U2: A.G.M.2 | Average charging voltage: 14.6V; Floating charging voltage: 13.7V (voltage of a single battery) | ||||||||
| U3: Sealed lead Acid | Average charging voltage: 14.4V; Floating charging voltage: 13.6V (voltage of a single battery) | ||||||||
| U4: Gel European | Average charging voltage: 14.4V; Floating charging voltage: 13.8V (voltage of a single battery) | ||||||||
| U5: Open lead Acid | Average charging voltage: 14.8V; Floating charging voltage: 13.5V (voltage of a single battery) | ||||||||
| U6: Calcuim(open) | Average charging voltage: 15.1V; Floating charging voltage: 13.6V (voltage of a single battery) | ||||||||
| U7: Sulphation cycle | 15.5V for 4 hours (single battery voltage) | ||||||||
| Custom Battery | Customized charging and discharging parameters for different types of batteries (such as lithium batteries, etc.) according to user requirements | ||||||||
| call the police | A | Normal working condition, no alarm sound from buzzer | |||||||
| B | When there is a battery failure, abnormal voltage, or overload protection, the buzzer will beep 4 times per second | ||||||||
| C | When the machine is turned on for the first time and functioning normally, the buzzer will sound 5 times | ||||||||
| environment | Operating Temperature | -10℃~40℃ | |||||||
| Storage temperature | -15℃~60℃ | ||||||||
| altitude | 2000m (use with reduced rating if exceeded) | ||||||||
| noise | ≤65dB | ||||||||
| relative humidity | 0%~95%, no condensation | ||||||||
| Note: Please contact the sales consultant to obtain the latest product specifications | |||||||||