HC4000
The HC4000 controller adopts a modular design, which can accurately measure the haze (turbidity) of the medium. It has a menu style software and a mul
Product details


Users can configure parameters in HC4000 according to their specific process requirements



  • Can connect multiple sensors
  • Configurable multiple sets of parameters
  • Provide multiple linearization tables
  • Data Recorder
  • Scattered light sensors have factory zero points
  • Can be remotely controlled


display mode

  • 1-4 simultaneous display values (adjustable)
  • A digital bar chart displaying the set alarm values
  • Trend Chart



Remote control

  • Parameter settings
  • zero calibration
  • Status Hold

software tool

  • 8 sets of parameters can be set (including range, alarm, display, etc.)
  • 16 linearized tables (up to 11 points can be defined)
  • 8 sets of compensation and gain values
  • Automatic zeroing (local or remote)
  • Factory zero point (only available for scattered light sensors)
  • Password protection (Level 3 password or none)
  • Memory (not easily lost) stores all configuration and recorded data





Technical Parameter
HC4000 控制器参数

If there are any changes to the data, no further notice will be given.



PROFIBUS ® PA

  • Meets the requirements of process automation application specifications (version 3.01)
  • Circular data includes:
    • 4 measurement results output, each measurement result has an alarm value and a status value
    • Status values of 4 relays
    • 2 input values
  • Non cyclic data includes:
    • Zero calibration, status maintenance, product switching, data from various monitors, fault codes
  • Provide GSD, EDD files, and DTM required for FDT interface
  • A coupler must be used from the PA interface to the DP interface


FOUNDATION ™ Fieldbus

  • Compliant with FOUNDATION ™ Fieldbus H1 (IEC 61158-2) specification
  • The functional modules include: 1 x RB, 8 x AI (s), 4 x DI (s), 2 x AO (s)
  • H1 specification level: 31P, 32L
  • H1 device level: basic device, link master device
  • Output of 4 measurement results with status values
  • 4 relay outputs with status values
  • 2 input values
  • Specific resource block parameters with optek: zero calibration, state maintenance, product switching
  • Provide device description (DD) and performance files