MDO-2000E Series Multi functional Hybrid Domain Oscilloscope - Capable of Time and Frequency Domain Operations
The MDO-2000E series will provide users with a better spectrum measurement experience.Undoubtedly, the best measurement device for frequency domain signals is a spectrum analyzer. However, if operated improperly, its high precision and high unit price often result in expensive maintenance costs. There are not many educational institution laboratories that can provide a spectrum analyzer for each student. Therefore, students from professional schools and higher education institutions lack practical experience in using spectrum analyzers. R&D engineers in small and medium-sized enterprises have also encountered the same problem. The spectrum analyzer of MDO-2000E redefines the indispensable function of oscilloscopes and allows every student to have a spectrum analyzer.
MDO-2000E series oscilloscopeMain features:
200/100MHz bandwidth selection (MDO-2000EG/MDO-2000EX);
200/100/70MHz bandwidth selection (MDO-2000EC/MDO-2000ES);
2 or 4 channels
The real-time sampling rate for each channel is 1GSa/s (2-channel model)
The maximum real-time sampling rate is 1GSa/s (4-channel model)
Each channel has a storage depth of 10M and VPO waveform display technology
• Waveform update rate up to 120000 wfms/s
8 "WVGA TFT LCD display
• Maximum 1M FFT provides higher frequency domain resolution measurement
• High pass, low-pass, and band-pass filter functions
29000 segmented memory and waveform search function
I2C/SPI/UART/CAN/LIN serial bus triggering and decoding function
The data recording function can track signal changes for up to 1000 hours
• Network storage function
Mask testing function
The MDO-2000E series is equipped with a spectrum analyzer and dual channel 25MHz AWG
The MDO-2000EX is equipped with a spectrum analyzer, dual channel 25MHz AWG, DMM, and power supply
MDO-2000EC is equipped with a logic analyzer
The MDO-2000ES is equipped with a logic analyzer, spectrum analyzer, dual channel 25MHz AWG, DMM, and power supply
• Interface high-speed USB device ports, host ports, LAN ports Go/NoGo BNC、Kensington Style lock
MDO-2000E series oscilloscope specifications
| MDO-2000E series specifications | |||||||
| MDO-2072EC | MDO-2074EC | MDO-2102EG | MDO-2104EG | MDO-2202EG | MDO-2204EG | ||
| MDO-2072ES | MDO-2074ES | MDO-2102EX | MDO-2104EX | MDO-2202EX | MDO-2204EX | ||
| MDO-2102EC | MDO-2104EC | MDO-2202EC | MDO-2204EC | ||||
| MDO-2102ES | MDO-2104ES | MDO-2202ES | MDO-2204ES | ||||
| thoroughfare | 2ch+Ext | 4ch | 2ch+Ext | 4ch | 2ch+Ext | 4ch | |
| bandwidth | DC~70MHz | DC~70MHz | DC~100MHz | DC~100MHz | DC~200MHz | DC~200MHz | |
| (-3dB) | (-3dB) | (-3dB) | (-3dB) | (-3dB) | (-3dB) | ||
| rise time | 5ns | 5ns | 3.5ns | 3.5ns | 1.75ns | 1.75ns | |
| Bandwidth limitation | 20MHz | 20MHz | 20MHz | 20MHz | 20M/100MHz | 20M/100MHz | |
| Vertical sensitivity | |||||||
| resolution | 8 bit | ||||||
| 1mV~10V/div | |||||||
| Input Coupling | AC, DC, GND | ||||||
| Input impedance | About 1M Ω//16pF | ||||||
| DC gain accuracy | ±(3%)when 2mV/div or greater is selected | ||||||
| ±(5%)when 1mV/div is selected; | |||||||
| polarity | Normal & Invert | ||||||
| Maximum input voltage | 300Vrms, CAT I | ||||||
| Offset position range | 1mV/div ~ 20mV/div : ±0.5V | ||||||
| 50mV/div ~ 200mV/div : ±5V | |||||||
| 500mV/div ~ 2V/div : ±25V | |||||||
| 5V~10V/div : ±250V | |||||||
| Waveform signal processing | +, -, ×, ÷, FFT, User Defined Expression. | ||||||
| FFT:1Mpts | |||||||
| FFT:Spectral magnitude. Set FFT Vertical Scale to Linear RMS or dBV RMS, and FFT Window to Rectangular, Hamming, Hanning, or Blackman. | |||||||
| trigger | |||||||
| Trigger Source | CH1 ,CH2, CH3, CH4, Line, EXT* | ||||||
| *Dual channel model | |||||||
| MODE | Automatic (supports Roll mode, 100 ms/div or slower), normal, single sequence | ||||||
| Trigger Type | Edge, pulse width (glitch), video, pulse voltage, rise and fall (slope), alternation, output, event delay (1-65535 events), delay (duration, 4nS -10S), bus | ||||||
| Release range | 4ns~10s | ||||||
| coupling | AC,DC,LFrej. ,HFrej. ,Noiserej. | ||||||
| sensitivity | 1div | ||||||
| external trigger | |||||||
| range | ±15V | ||||||
| sensitivity | DC~100MHz approximately 100mV | ||||||
| 100MHz~200MHz approximately 150mV | |||||||
| Input impedance | 1MΩ±3%~16pF | ||||||
| level | |||||||
| Time Base Range | 1ns/div ~ 100s/div (1-2-5 increments) | ||||||
| ROLL: 100ms/div ~ 100s/div | |||||||
| pre-trigger | Maximum 10 div | ||||||
| post-trigger | Maximum 2000000 div | ||||||
| Time base accuracy | ± 50 ppm over any ≥ 1 ms time interval | ||||||
| Real time sampling rate | maximum.: 1GSa/s (4ch model) | ||||||
| 1GSa/s per channel (2ch model) | |||||||
| Record length | 10M pts per channel | ||||||
| Acquisition mode | Normal, average, peak detection, single time | ||||||
| peak detection | 2ns (typical value) | ||||||
| average value | Available from 2 to 256 | ||||||
| X-Y mode | |||||||
| X-axis input | Channel 1; Channel 3* | ||||||
| *Only four channel models available | |||||||
| Y-axis input | Channel 2; Channel 4* | ||||||
| *Only four channel models available | |||||||
| phase shift | ±3° at 100kHz | ||||||
| Cursor and measurement | |||||||
| cursor | Amplitude, time, gating; Unit: seconds, Hz(1 / s), Phase (degree), quantitative (%) | ||||||
| automatic measurement | 38 groups: Pk-Pk, Maximum, minimum, amplitude, high, low, average, period average, RMS, RMS cycle, area, cycle area, ROVShoot,FOVShoot,RPREShoot,FPREShoot, Frequency, cycle, rise time, width, duty cycle,+pulse, - pulse,+edge, - pulse,% flicker, flicker Idx, FRR,FRF,FFR,FFF,LRR,LRF,LFR,LFF, phase | ||||||
| Control panel functions | |||||||
| auto counter | 6-digit, ranging from minimum 2Hz to rated bandwidth | ||||||
| Automatic setting | Single button, automatically set all channels for vertical, horizontal, and trigger systems, with the ability to undo automatic settings | ||||||
| Save Settings | 20 sets | ||||||
| Save waveform | 24 sets | ||||||
| display | |||||||
| TFT LCD type | 8 "TFT LCD WVGA color display | ||||||
| display resolution | 800 horizontal x 480 vertical pixels (WVGA) | ||||||
| interpolation | Sin(x)/x | ||||||
| DISPLAY | Point, vector, variable persistence (16ms? 4s), infinite persistence | ||||||
| Waveform update rate | Maximum 120000 waveforms per second | ||||||
| display scale | 8 x 10 divisions | ||||||
| display mode | YT ; XY | ||||||
| interface | |||||||
| USB port | USB 2.0 high-speed host port X1, USB 2.0 high-speed device port X1 | ||||||
| Ethernet (LAN) port | RJ-45 connector, 10/100Mbps with HP Auto-MDIX | ||||||
| Go-NoGo BNC | 5V Max/10mA TTL collector open circuit output | ||||||
| Kensington Style Lock | Connect the rear panel security slot to the standard Kensington style lock | ||||||
| Spectrum analyzer specifications | |||||||
| Frequency range | DC~500MHz (Max. ,Max.bandwidth~500MHz uncalibrated) | ||||||
| Scan width | 1kHz~500MHz(Max.) | ||||||
| resolution bandwidth | 1Hz ~ 500kHz(Max.) | ||||||
| Reference level | -50 dBm to +40dBm in steps of 5dBm | ||||||
| Vertical unit | dBV RMS; Linear RMS; dBm | ||||||
| Vertical position | -12divs to +12divs | ||||||
| vertical scale | 1dB/div to 20dB/div in a 1-2-5 Sequence | ||||||
| Display the average noise level | 1V/div < -50dBm, Avg : 16 | ||||||
| 100mV/div < -70dBm, Avg : 16 | |||||||
| 10mV/div < -90dBm, Avg : 16 | |||||||
| Spurious response | 2nd harmonic distortion<40dBc | ||||||
| 3rd harmonic distortion<45dBc | |||||||
| Frequency domain tracking type | Normal ; Max Hold ; Min Hold ; Average (2 ~ 256) | ||||||
| test method | Sample ; + Peak ; - Peak ; Average | ||||||
| FFT Windows | FFT Factor : | ||||||
| Hanning 1.44 | |||||||
| Rectangular 0.89 | |||||||
| Hamming 1.30 | |||||||
| Blackman 1.68 | |||||||
| Arbitrary Signal Generator (AWG) specifications | |||||||
| thoroughfare | 2 | ||||||
| sampling rate | 200 Msa/s | ||||||
| Vertical Resolution | 14 bits | ||||||
| Maximum frequency | 25 MHz | ||||||
| wave form | Sine, Square, Pulse, Ramp, DC, Noise, Sinc, Gaussian, Lorentz, Exponential Rise, Exponential Fall, Haversine, Cardiac | ||||||
| Output range | 20 mVpp to 5 Vpp, HighZ; 10 mVpp to 2.5 Vpp, 50 Ω | ||||||
| Output Resolution | 1mV | ||||||
| output accuracy | 2% (1 kHz) | ||||||
| Offset Range | ±2.5 V, HighZ; ±1.25 V, 50 Ω | ||||||
| Offset resolution | 1mV | ||||||
| Sine | |||||||
| Frequency range | 100mHz to 25MHz | ||||||
| evenness | ±0.5 dB( relative to 1kHz) | ||||||
| harmonic distortion | -40 dBc | ||||||
| Distortion (non harmonic) | -40 dBc | ||||||
| Total harmonic distortion | 1% | ||||||
| S/N Ratio | 40 dB | ||||||
| Square/Pulse | |||||||
| Frequency range | 100 mHz to 15MHz | ||||||
| Rise/fall time | <15ns<> | ||||||
| radical | <3%<> | ||||||
| Duty cycle | Square wave: 50%; Pulse wave: 0.4%~99.6% | ||||||
| minimum pulse width | 30 ns | ||||||
| shake | 500 ps | ||||||
| Ramp | |||||||
| Frequency range | 100mHz~1MHz | ||||||
| Linearity | 1% | ||||||
| symmetry | 0 to 100% | ||||||
| Specification of Digital Multimeter (DMM) (MDO-2000EX/MDO-2000ES models only) | |||||||
| 5,000 counts | |||||||
| DIGIT LEVEL | CAT II 600Vrms, CAT III 300Vrms | ||||||
| DC voltage | 50mV, 500mV, 5V, 50V, 500V, 1000V 6 ranges | ||||||
| accuracy | 50mV, 500mV, 5V, 50V, 500V, 1000V ±(0.1% reading + 5 digits) | ||||||
| Input impedance | 10MΩ | ||||||
| DC current | 50mA, 500mA, 10A 3 ranges | ||||||
| accuracy | 50mA - 500mA ±(0.5% reading + 0.05mA) | ||||||
| 10A ±(0.5% reading + 50mA) | |||||||
| AC voltage | 50mV, 500mV, 5V, 50V, 700V 5 ranges | ||||||
| accuracy | 50mV, 500mV, 5V, 50V, 700V ±(1.5% reading + 15 digits) at 50Hz-1kHz | ||||||
| * Amplitude greater than 0.2% of the full scale reading. | |||||||
| AC current | 50mA, 500mA, 10A 3 ranges | ||||||
| accuracy | 50mA, 500mA, ±(1.5% reading + 0.05mA) at 50Hz-1kHz | ||||||
| 10A ±(3% reading + 50mA) at 50Hz-1kHz | |||||||
| * Measure range: > 10mA | |||||||
| resistance | 500Ω, 5kΩ, 50kΩ, 500kΩ, 5MΩ, 5 ranges | ||||||
| accuracy | 500Ω, 5kΩ, 50kΩ, 500kΩ ±(0.3% reading + 3 digits) | ||||||
| 5MΩ ±(0.5% reading + 5 digits) | |||||||
| Power specifications (only for MDO-2000EX/MDO-2000ES models) | |||||||
| Output channel | CH1 & CH2 | ||||||
| Output voltage range | 1.0V~5.0V | ||||||
| Output current (maximum) | 1A | ||||||
| Voltage Step | 0.1V continuously adjustable | ||||||
| voltage accuracy | ±3% | ||||||
| RIPPLE AND NOISE | 50mVrms | ||||||
| Logic analyzer specifications (only applicable to MDO-2000EC/MDO-2000ES models) | |||||||
| Sampling rate | 1GSa/s per channel | ||||||
| memory depth | 10M pts (max) per channel | ||||||
| Channel | 16 Digital (D15 - D0) | ||||||
| Trigger Type | Edge, Pattern, Pulse Width, Serial bus (I2C, SPI, UART(RS232/422/485), CAN, LIN), Parallel Bus | ||||||
| Critical value grouping | D0~D3, D4~D7,D8~D11 ,D12~D15 Thresholds | ||||||
| Critical value selection | TTL, CMOS(5V,3.3V,2.5V), ECL, PECL,0V ,User Defined | ||||||
| User defined critical value range | ±5V | ||||||
| Maximum input voltage | ±40 V | ||||||
| Minimum driving voltage | ±250 mV | ||||||
| Vertical Resolution | 1 bit | ||||||
| Other functions | |||||||
| Multi language menu | available | ||||||
| operating environment | Temperature: 0°C to 50°C. Relative humidity ≤ 80% below 40 ° C; ≤ 45% at 41 ° C~50 ° C | ||||||
| Online Help | Available | ||||||
| clock | Time and Date ,Provide the Date/Time for saved data | ||||||
| size | 384mmX208mmX127.3mm | ||||||
| weight | 3kg | ||||||
ordering information
MDO-2204EG200MHz , 4-channel, digital storage oscilloscope, spectrum analyzer, dual channel 25MHz AWG
MDO-2104EG 100MHz , 4-channel, digital storage oscilloscope, spectrum analyzer, dual channel 25MHz AWG
MDO-2202EG200MHz , 2-channel, digital storage oscilloscope, spectrum analyzer, dual channel 25MHz AWG
MDO-2102EG 100MHz , 2-channel, digital storage oscilloscope, spectrum analyzer, dual channel 25MHz AWG
MDO-2204EX200MHz , 4-channel, digital storage oscilloscope, spectrum analyzer, dual channel 25MHz AWG, 5000 count DMM and power supply
MDO-2104EX 100MHz , 4-channel, digital storage oscilloscope, spectrum analyzer, dual channel 25MHz AWG, 5000 count DMM and power supply
MDO-2202EX200MHz , 2-channel, digital storage oscilloscope, spectrum analyzer, dual channel 25MHz AWG, 5000 count DMM and power supply
MDO-2102EX 100MHz , 2-channel, digital storage oscilloscope, spectrum analyzer, dual channel 25MHz AWG, 5000 count DMM and power supply
MDO-2204EC200MHz , 4-channel, digital storage oscilloscope, 16ch logic analyzer, spectrum analyzer, dual channel 25MHz AWG
MDO-2104EC 100MHz , 4-channel, digital storage oscilloscope, 16ch logic analyzer, spectrum analyzer, dual channel 25MHz AWG
MDO-2074EC 70MHz , 4-channel, digital storage oscilloscope, 16ch logic analyzer, spectrum analyzer, dual channel 25MHz AWG
MDO-2202EC200MHz , 2-channel, digital storage oscilloscope, 16ch logic analyzer, spectrum analyzer, dual channel 25MHz AWG
MDO-2102EC 100MHz , 2-channel, digital storage oscilloscope, 16ch logic analyzer, spectrum analyzer, dual channel 25MHz AWG
MDO-2072EC 70MHz , 2-channel, digital storage oscilloscope, 16ch logic analyzer, spectrum analyzer, dual channel 25MHz AWG
MDO-2204ES200MHz , 4-channel, digital storage oscilloscope, 16ch logic analyzer, spectrum analyzer, dual channel 25MHz AWG, 5000 count DMM and power supply
MDO-2104ES100MHz , 4-channel, digital storage oscilloscope, 16ch logic analyzer, spectrum analyzer, dual channel 25MHz AWG, 5000 count DMM and power supply
MDO-2074ES70MHz , 4-channel, digital storage oscilloscope, 16ch logic analyzer, spectrum analyzer, dual channel 25MHz AWG, 5000 count DMM and power supply
MDO-2202ES200MHz , 2-channel, digital storage oscilloscope, 16ch logic analyzer, spectrum analyzer, dual channel 25MHz AWG, 5000 count DMM and power supply
MDO-2202ES200MHz , 2-channel, digital storage oscilloscope, 16ch logic analyzer, spectrum analyzer, dual channel 25MHz AWG, 5000 count DMM and power supply
MDO-2072ES70MHz , 2-channel, digital storage oscilloscope, 16ch logic analyzer, spectrum analyzer, dual channel 25MHz AWG, 5000 count DMM and power supply