Guangdong Luhe UV Disinfector Tube UV DisinfectorThe strong UV-C light generated by a specially designed high-efficiency, high-intensity, and long-life UV-C light generating device is used to irradiate flowing water. The treated water enters the reactor through the inlet of the ultraviolet sterilizer (UV sterilizer) and flows through the reaction chamber at a certain speed. The internal structure of microbial DNA and RNA is damaged and cannot replicate, thus meeting the national inspection standards without using any chemical drugs. The spectral line with a wavelength of 185nm can also decompose organic molecules in water, generate hydrogen radicals, and oxidize organic molecules in water to carbon dioxide, achieving the goal of removing TOC.
Product features of UV disinfection machine:
304 or 316 polished stainless steel;
·Quartz sleeve to ensure the highest UV transmittance;
High output, using hard glass ultraviolet lamps to achieve maximum efficiency;
·Sound and visual lighting alarm devices;
·A precise nanometer ultraviolet monitoring device is composed of various output devices, including light-emitting diodes and measuring instruments;
·The all stainless steel shell is treated with anodic rust prevention;
Using thermistor to control the control board and reactor;
·Using an electronic timer;
·Solenoid valves and remote control equipment, including infrared output devices;
The equipment is clean, electroplated and polished, suitable for high purification environments;
·The electrical configuration of the equipment is suitable for markets around the world;
Specially designed appearance, more convenient to use.
Guangdong Luhe UV Disinfector Tube UV DisinfectorPurpose and classification
The removal rate of various viruses and bacteria from seawater, freshwater, or other water bodies treated with a UV sterilizer can reach over 99.99%.
Under the premise that the removal rate of viruses and bacteria in the water body reaches 99.99% or above, the cost of treating each ton of water ranges from 4 cents to 1 cent RMB (depending on the cleanliness of the water body).
3. Improve seawater and freshwater seedling cultivation, with a survival rate of over 50% (depending on the survival rate without sterilization)
4. Accelerate the growth rate of aquaculture populations.
5. Improve the overall health level of seedlings and breeding populations, cultivate healthy seedlings and healthy adults.
Without changing the original ingredients, taste, and color of various beverages and other fluid foods, the removal rate of pathogenic bacteria and other pathogens can reach over 99.99%.
7. UV pre-treatment is used to sterilize swimming pool water, and the chlorine content in the water can be reduced to 0.5 mg/L. The removal rate of viruses and bacteria is over 99.99%.
8. Adding UV sterilization to the application water terminal can achieve the standard of direct application of water.
9. Sterilize urban sewage, reducing the total bacterial count to below 200 per 100ml and Escherichia coli to below 20 per 100ml.
Model parameters:
model |
Water treatment capacity |
Imported pipe diameter |
power |
External dimensions |
Working pressure MPa |
Φ×L | |||||
GY55-4 |
18-20 |
80 |
220 |
219×1300 |
0.6 |
GY55-5 |
22-25 |
80 |
275 |
219×1300 |
0.6 |
GY55-6 |
30-35 |
100 |
330 |
219×1300 |
0.6 |
GY55-8 |
45-48 |
100 |
440 |
250×1300 |
0.6 |
GY55-10 |
70-75 |
125 |
550 |
250×1300 |
0.6 |
GY75-4 |
25-30 |
80 |
300 |
219×1660 |
0.6 |
GY75-5 |
35-40 |
100 |
375 |
219×1660 |
0.6 |
GY75-6 |
45-50 |
100 |
450 |
219×1660 |
0.6 |
GY75-7 |
55-58 |
125 |
525 |
250×1660 |
0.6 |
GY75-8 |
60-65 |
133 |
600 |
250×1660 |
0.6 |
GY75-9 |
70-80 |
150 |
675 |
300×1660 |
0.6 |
GY75-10 |
80-100 |
150 |
750 |
300×1660 |
0.6 |
GY150-4 |
75--80 |
133 |
600 |
219×1660 |
0.8 |
GY150-5 |
90-110 |
150 |
750 |
219×1660 |
0.8 |
GY150-6 |
120-130 |
150 |
900 |
250×1660 |
0.8 |
GY150-7 |
140-160 |
150 |
1050 |
250×1660 |
0.8 |
GY150-8 |
170-180 |
200 |
1200 |
300×1660 |
0.8 |
GY150-9 |
200-210 |
200 |
1350 |
300×1660 |
0.8 |
GY150-10 |
230-240 |
200 |
1500 |
350×1660 |
1.0 |
GY150-11 |
260-280 |
250 |
1650 |
350×1660 |
1.0 |
GY150-12 |
300--320 |
250 |
1800 |
350×1660 |
1.0 |
GY300-8 |
400-430 |
250 |
2400 |
350×1660 |
1.0 |
GY300-10 |
460-510 |
250 |
3000 |
350×1660 |
1.0 |
GY300-14 |
600-650 |
300 |
4200 |
400×1660 |
1.0 |
GY300-20 |
800-900 |
350 |
6000 |
500×1660 |
1.0 |
Attachment: 1. The equipment provided in this technical parameter table is suitable for sterilization of purified water quality, such as tap water, purified water, aquaculture water, food processing water, differentiated water supply, pharmaceutical water, etc.
2. The sterilization efficiency depends on the transparency, impurities, and temperature of the water body, with a minimum of 99.9% or special design.
3. Manual or automatic cleaning devices can be configured according to customer needs.
Best usage conditions:
(1) Water temperature: 5 ℃~60 ℃; Operating environment temperature: -5 ℃~50 ℃; Relative humidity around: not exceeding 93% (at a temperature of 25 ℃)
(2) Voltage: AC 220V ± 10V, 50Hz.
(3) Drinking water: The water entering the treatment equipment has a transmittance (T254) of 1cm, ranging from 95% to 100%; When the original water quality is lower than the national drinking water standard (such as chromaticity higher than 15 degrees, turbidity higher than 5 degrees, iron content higher than 0.3 milligrams per liter), other purification and filtration methods should be used first to purify it to meet the standard, and then use UV-C water treatment equipment for purification.
(4) Aquaculture water: Fresh water and seawater treated and filtered by sand filtration or other equipment.
(5) Wastewater: According to sterilization requirements, the transmittance (T254) of water entering the treatment equipment at 1cm is ≥ 40%; Other requirements must meet the second level standards in the national "Comprehensive Wastewater Discharge Standard" GB8978-1996.
Maintenance and upkeep
(1) Regularly check to ensure the normal operation of the UV lamp.
(2) After continuous use for 9000 hours or one year, the ultraviolet lamp tube should be replaced to ensure a high sterilization rate. Please pay special attention to keeping the ultraviolet light on continuously, as repeated turning on and off can seriously affect the service life of the lamp.
(3) When replacing the ultraviolet lamp, first unplug the lamp power socket and take out the ultraviolet lamp. When replacing the new lamp tube, be careful not to touch the quartz glass of the new lamp tube with your fingers, as stains can affect the sterilization light. At the same time, carefully place the lamp tube into the stainless steel sterilizer.
(4) If there are substances with hardness (calcium or magnesium), iron or manganese in the water, then the quartz tube needs to be cleaned regularly. After cleaning the quartz tube, special plastic gloves should be worn to carefully install the quartz tube into the reactor. After installing the sealing ring, check for any water leakage, plug in the power supply, and ensure that the detection lamp emits stable light.
Note: Ultraviolet radiation has a strong killing effect on bacteria and can also cause certain harm to the human body. The most vulnerable part of the human body is the eyes, so it is not advisable to look directly at lit lamps at any time to avoid injury.
Installation precautions
1. The ultraviolet sterilization device should be placed in a place that is easy to clean and inspect.
2. For the convenience of replacing accessories and installing ultraviolet sterilization devices, there should be a certain amount of space on both sides of the device, depending on the specific model.
3. Do not allow equipment to freeze.
4. It is recommended to use an environment temperature not exceeding 60 ℃.
5. When using power sources other than 200V/50Hz, please consult the seller first.
6. The maximum working pressure of the UV sterilizer is 1.2mpa
Compared with disinfection equipment produced by other manufacturers, the ultraviolet sterilizer (UV sterilizer) produced by Jiguan Company has sealed heads on both sides, no dead corners of water flow, no residue, and thorough disinfection. The tube wall shell is made of 2.5mm204 genuine stainless steel, with a pressure bearing capacity of up to 16 kilograms, sturdy and durable. The lamp tube is imported from the United States and has a service life of more than 12000 hours. It is thoroughly sterilized and widely used in secondary water supply disinfection, drinking water disinfection, purified water, mineral water disinfection, and swimming pool water disinfection. And can be made according to customer requirements, including frame type UV sterilizers (UV sterilizers), automatic cleaning UV sterilizers (UV sterilizers), manual cleaning UV sterilizers (UV sterilizers), open channel type UV sterilizers (UV sterilizers), upper and lower type UV sterilizers (UV sterilizers), large split type UV sterilizers (UV sterilizers), etc