German WTW Cond7310 desktop conductivity meter (SF free shipping)Product Introduction:
(1) Characteristics
InoLab Cond 7310 is suitable for precise measurement of conductivity, suitable for GLP/AQA laboratories, and has data recording capabilities
The main features of USB interface, CMC, and printer selection include:
1. USB interface for fast data transfer;
2. Complete CSV format data transmission;
3. Optional built-in printer for data output.
(2) Accurate measurement+documentation
The 7310 series provides measurements of pH, conductivity, and dissolved oxygen. Suitable for all laboratory applications that require support for AQA and GLP documentation. These instruments provide all the features of the 7110 series and also add some additional functions.
(3) Easy to operate
The display interface provides convenient and secure operation. All necessary information is displayed on a bright and clear screen, which can be seen at a glance.
(4) Record
For the convenience of transferring general or stored data, the inoLab 7310 series is connected to a PC via a USB interface. A built-in data logger with adjustable storage intervals provides automatic recording of all measurement data. The date, time, and ID number comply with good laboratory practices. Users can also input the sensor serial number to request the complete document. All data can be transmitted in a CSV format that is easy to process; WTW provides an additional Excel file for measuring, designing, and calibrating records.
InoLab ® 7310P provides a built-in printer for directly printing measurement and calibration results.
German WTW Cond7310 desktop conductivity meter (SF free shipping)Technical parameters:
instrumentinoLab ® Cond 7310
All values+/-1 word
conductivity0 µ S/cm... 1000 mS/cm+/-0.5% measurement value
0.000 . .. 1.999 µS/cm, K= 0.01 cm-1
0.00 . .. 19.99 µS/cm, K= 0.01 cm-1
resistivity0.00 . .. 20 MOhm cm
Electrode constant0.450 . .. 0.500 cm-1, 0.800 ... 0.880 cm-1,
Fixed 0.01 cm-1
Standard solution: 0.01 mol/L KCl
Adjustment range: 0.090... 0.110 cm-1, 0.250... 25.000 cm-1
salinity0.0 … 70.0 (acc. IOT)
TDS0 … 1999 mg/l, 0 … 199.9 g/l
Celsius/Fahrenheitcorrect
temperature-5.0 … 105.0 °C +/- 0,1 °C
Auto ReadAuto/Manual
Sensor plug8 pin
calibrationone o'clock
reference temperature20 °C/25 °C
temperature compensationNone, nLF nonlinear, linear 0.000... 10.00%/K
Calibration capacity*10 more calibration records
displayBacklit LCD
storage500 sets of manual/5000 sets of automatic
RecorderManual/time control
interfaceMini USB
Printer (optional)Hot printing, width 58 mm
power supplyUniversal power supply, 4x1,5 V AA or 4 x 1,2 V rechargeable batteries
Ordering information:
inoLab®Cond 7310 | Simple and reliable,conform toGLP/AQAThe required desktop conductivity measuring instrument host is for routine applications, powered by batteries and AC electricity,Single parameter, including operation manual,CD-ROM(including software) andUSBline,Excluding electrodes. | 1CA300 |
inoLab®Cond 7310 SET 1 | Simple and reliable,conform toGLP/AQAThe required desktop conductivity measuring instrument host is for routine applications, powered by batteries and AC electricity,Single parameter, including operation manual,CD-ROM(including software) andUSBWire, conductive electrodeTetraCon®325,Conductivity Standard1413µS/cm. | 1CA301 |
inoLab®Cond 7310 SET 6 | Simple and reliable,conform toGLP/AQAThe required desktop conductivity measuring instrument host is for routine applications, powered by batteries and AC electricity,Single parameter, including operation manual,CD-ROM(including software) andUSBWire and pure water conductivity measurement kitUSP KIT1. | 1CA306 |
inoLab®Cond 7310P | Simple and reliable,conform toGLP/AQAThe required desktop conductivity measuring instrument host is for routine applications, powered by batteries and AC electricity,Single parameter, including operation manual,CD-ROM(including software) andUSBWire, printer, without electrodes. | 1CA300P |
inoLab®Cond 7310P SET 1 | Simple and reliable,conform toGLP/AQAThe required desktop conductivity measuring instrument host is for routine applications, powered by batteries and AC electricity,Single parameter, including operation manual,CD-ROM(including software)), USBWire, printer, conductive electrodeTetraCon® 325Conductivity standard solution1413µS/cm. | 1CA301P |
inoLab®Cond 7310P SET 6 | Simple and reliable,conform toGLP/AQAThe required desktop conductivity measuring instrument host is for routine applications, powered by batteries and AC electricity,Single parameter, including operation manual,CD-ROM(including software), USBWire and pure water conductivity measurement kitUSP Kit 1And the printer. | 1CA306P |
TetraCon ® three hundred and twenty-five | Quadrupole conductivity electrode,Cable length1.5mConductivity measurement range:1µS/cm-2S/cm,Apply surface water, groundwater, sewage, food industry, swimming pool water, etc. | 301960 |
KLE 325 | Two pole conductive electrode, conductivity measurement range:10µS/cm-20mS/cm,Cable Length1.5m. | 301995 |
USP KIT1 | Pure water conductivity measurement kit that complies with pharmacopoeia. | 300569 |