Home>Products>Gas chromatograph for detecting methane and non methane total hydrocarbons
Gas chromatograph for detecting methane and non methane total hydrocarbons
Gas chromatograph for detecting methane and non methane total hydrocarbons
Product details

Product Introduction:




Methane and non methane total hydrocarbon detection
Specialized gas chromatographGC-7900
1. Definition:
Non methane total hydrocarbons (NMHC) typically refer to all volatile hydrocarbons other than methane, also known as non methane total hydrocarbons. When the concentration of NMHC in the atmosphere exceeds a certain level, it is harmful to human health and can also produce chemical smoke, causing harm to the environment and humans.
2. Testing standards:
The factory boundary concentration standard for non methane total hydrocarbons in China's "Comprehensive Emission Standards for Air Pollutants" (GB16927-1996) is 0.05mg/m3
According to the fourth edition of the "Air and Waste Gas Monitoring Methods", the GC-7900 gas chromatograph adopts a single FID detection process with a ten way valve injection and dual column parallel connection, effectively eliminating measurement errors caused by differences in FID sensitivity during dual FID analysis. It meets the detection requirements for total hydrocarbons and non methane total hydrocarbons in the air, with a minimum detection concentration of 0.05mg/m3; And only one injection is needed to analyze both total hydrocarbons and non methane total hydrocarbons simultaneously. An automatic sampling and injection system can be optionally selected, as well as automatic online analysis. Please call to explain when placing an order.
3. GC-7900Instrument Introduction:
● Operation display:192×64Dot matrix LCD, large screen Chinese display.
Adopting a microcomputer automatic ignition device.
Stable and reliable digital zeroing is adopted to avoid baseline instability caused by potentiometer zeroing.
Equipped with a ten way valve injection structure system, specifically designed for the detection of non methane total hydrocarbons, it features a parallel installation of two chromatography columns and a highly sensitive FID detector specifically designed for total hydrocarbon analysis.The single FID detection process effectively eliminates measurement errors caused by differences in FID sensitivity during dual FID analysis, meeting the detection requirements for total hydrocarbons and non methane total hydrocarbons in the air, with a minimum detection concentration of 0.05mg/m3; And only one injection is needed to analyze both total hydrocarbons and non methane total hydrocarbons simultaneously.
Equipped with a five stage program heating function, intelligent rear door variable frequency automatic cooling,The cooling rate is very fast, achieving true near room temperature operation.
Equipped with over temperature protection function, the power automatically shuts off and an alarm is triggered when the temperature exceeds the set upper limit. If the temperature of any circuit exceeds the set temperature, heating will automatically stop; And there are Chinese prompts for the cause of the fault and alarm prompts.

4.GC-7900Main technical indicators:
1.
Temperature control:
Temperature control range: room temperature +8-420
Temperature control accuracy: within 200Within is±0.1In200The above is±0.2
Heating rate:1-30/minute
2.
Detector indicators:
FID:
detection limit:Mf 1×10-11g/s(benzene)
Noise sound:0.02mv
float move:0.1mv/h
5. Analysis method:
According to the Comprehensive Emission Standards for Air Pollutants (GB16927-1996), the standard gas injection quantitative and qualitative analysis method is adopted.
The specific analysis method steps can be found in the training materials provided by our company's installation and training personnel.
6.Instrument procurement configuration:

number
configuration
unit
quantity
notes
1
GC-7900gas chromatograph
tower
1
2
Ten way valve
only
1
3
Stainless steel analytical column
root
2
Total hydrocarbon analysis column and methane analysis column
4
Standard gas
bottle
1
Methane standard gas and hydrocarbon removal air
5
100mlGlass syringe
branch
5
6
10mlGlass syringe
branch
5
7
N2000Chromatography workstation
cover
1
8
Computer/Printer
cover
1
User provided
9
High purity nitrogen
bottle
1
User provided nitrogen gas cylinder
10
High purity hydrogen generator
tower
1
Users can bring their own hydrogen gas cylinders
11
Air generator
tower
1
Users can bring their own air cylinders

Remarks:

1. The above attachments can be deleted according to the actual needs of the user, and the computer and printer should be provided by themselves

2.
Payment to5Shipment within working days.

3.
Product warranty for one year, lifetime maintenance responsibility.

4.
Free on-site installation and debugging, training two analysis operators for users, and providing free chromatographic technology consultation.

5.
Acceptance method and deadline for raising objections: Acceptance shall be conducted according to the factory standards, and objections can be raised within one week.

6.
Spare parts and tools: according to the packing list.

7.
Formal purchase can choose to sign the 'Product Purchase and Sale Contract'