VIP member
Product details
technical parameter
● Detector
·TCD sensitivity ≥ 5000mV. ml/mg (n-C)16)
·FID monitoring limit ≤ 1 × 10-11g/S(n-C16)
·ECD monitoring limit ≤ 4 × 10-13G/S (Hexachlorobenzene)
·FPD [P] monitoring limit ≤ 5 × 10-12G/S (Methyl parathion)
[S] Monitoring limit ≤ 1 × 10-10G/S (Methyl parathion)
● Detector
·TCD sensitivity ≥ 5000mV. ml/mg (n-C)16)
·FID monitoring limit ≤ 1 × 10-11g/S(n-C16)
·ECD monitoring limit ≤ 4 × 10-13G/S (Hexachlorobenzene)
·FPD [P] monitoring limit ≤ 5 × 10-12G/S (Methyl parathion)
[S] Monitoring limit ≤ 1 × 10-10G/S (Methyl parathion)
● Temperature control
·Chromatography column box: above room temperature 20 ℃~400 ℃
·Sample injector box: above room temperature 20 ℃~400 ℃
·Ionization box: above room temperature 20 ℃~400 ℃
·TCD monitor box: above room temperature 20 ℃~350 ℃
● Power supply: AC 220V ± 22V 50Hz ± 0.5Hz 15A·Chromatography column box: above room temperature 20 ℃~400 ℃
·Sample injector box: above room temperature 20 ℃~400 ℃
·Ionization box: above room temperature 20 ℃~400 ℃
·TCD monitor box: above room temperature 20 ℃~350 ℃
● Dimensions: Height x Width x Depth 445 x 550 x 560mm3
Net weight: approximately 38Kg
main features
·Easy to operate: Set and display the electrical parameters of the instrument in the form of a page, and the operator can quickly master the usage of the instrument
·Self diagnostic function: and display basic fault information
·Real time zeroing: The output can be zeroed in real-time before analysis.
·Four channel stability control: column box, sampler box, TCD detector box, and ionization detector box.
·Five stage program heating: heating rate of 0.1-30 ℃/min
·Four types of detectors are available for selection: TCD、FID、 ECD、 FPD
·Injector: Two sets of packed column injectors and one set of capillary column injectors can be installed simultaneously
Comprehensive service:
According to your needs, we can select supporting equipment for your instruments, such as chromatography workstations, integrators, nitrogen hydrogen air source generators, standard gases, etc. Before purchasing the instrument, we will assist you in fully understanding the performance characteristics of the instrument and the most suitable analysis projects. After sales, we will send professional technical personnel to install, start and debug it for free. Free maintenance during the warranty period, regular product application, operation, and maintenance classes are held every year to serve you wholeheartedly!
Online inquiry