American AII/ADVCompany oxygen sensor/Oxygen cell/fuel cellOverviewTable:
Oxygen sensor GPR-12-333, oxygen cell GPR-12-333,Fuel cell GPR-12-333
Oxygen sensor PSR-12-223, oxygen cell PSR-12-223, fuel cell PSR-12-223
Oxygen sensor XLT-12-333, oxygen cell XLT-12-333,Fuel Cell XLT-12-333
Oxygen SensorGPR-12-2000MS,Oxygen cell GPR-12-2000MS,Fuel Cell GPR-12-2000MS
Oxygen cell GPR-12-100-M, oxygen sensor GPR-12-100-M, fuel cell GPR-12-100-M
Oxygen sensor GPR-12-233-H, oxygen cell GPR-12-233-H,Fuel Cell GPR-12-233-H
Oxygen sensor GPR-12-2000MS-2GPR-12-2000MS oxygen cell-2,Fuel Cell GPR-12-2000MS-2
Oxygen sensor GPR-11-32-4, oxygen cell GPR-11-32-4,Fuel cell GPR-11-32-4
Oxygen sensor GPR-11-60-4, oxygen cell GPR-11-60-4,Fuel cell GPR-11-60-4
Oxygen sensor GPR-11-120-RTS, oxygen cell GPR-11-120-RTS, fuel cell GPR-12-100-4
Oxygen sensor GPR-11-32-RTS, oxygen cell GPR-11-32-RTS,Fuel Cell GPR-11-32-RTS
Oxygen sensor XLT-11-24-RTS, oxygen cell XLT-11-24-RTS,Fuel Cell XLT-11-24-RTS
Oxygen SensorGPR-12-2000-MS2Oxygen batteriesGPR-12-2000-MS2,fuel cellGPR-12-2000-MS2
Oxygen sensor GPR-11-32, oxygen cell GPR-11-32,Fuel cell GPR-11-32
Oxygen sensor GPR-11-32-4, oxygen cell GPR-11-32-4,Fuel cell GPR-11-32-4
Rechargeable Battery A1163, GRP-1200 Micro Oxygen Rechargeable Battery A1163
GPR-1200MS portable trace oxygen analyzer range: 0-1/10/1000ppm, accuracy: 1% of the range;trace oxygen analyzerGPR-1200MS Automatic/Manual Range Adjustment American AIIoxygen analyzerMeasurement: Inert gas (O2 content 10pppb~1000ppm); He; H2 hydrogen, N2 nitrogen; mixed gases, hydrocarbons, acidic gases, natural gas, coal gas.
Technical parameters:
Accuracy:<1% of full scale
Range: 0-1, 0-100, 0-100, 0-1000ppm adjustable
Application: Analyze the oxygen content in inert gases, hydrocarbon gases, He, H2, and CO2 from 10ppb-1000ppm.
Certification: CE, Intrinsic Safety Type
Regional level: intrinsically safe design, suitable for Class I, Div.I, Goups A, B, C, D
Alarm: None
Calibration: Is the door of the garment perfect for a home? Certified standard gases with a range of 80% or higher
Compensation: Temperature
Interface: 1/8 "connector
Control: Range selection switch, waterproof key, calibration and system functions
Display: 2.75 "× 1.375"; Resolution: 0.01ppm; Real time display of temperature and pressure
Appearance: NEMA 4X, 8.6 * 9 * 3 "12 lbs
Traffic impact: 0.25-2.5L/m, recommended traffic: 1L/M
LED display light: low battery and charging mode
Linear:>0.995 exceeds all ranges
Pressure: Injection 5-30psig; Evacuation - Atmospheric pressure
Power supply: rechargeable battery, single battery can last for 60 days, pump on for 1 day
Recovery time: Exposure to air for 60 seconds and recovery to 10ppm with nitrogen gas takes 20 minutes
Response time: 90% full scale is 10 seconds
Sampling system: flow control and sample gas/bypass valve, flow indication
Sensitivity:<0.5% of full scale
Sensor model: GPR-12-2000MS, maintenance free
Sensor lifespan: 24 months, 25 ℃, average O2<100ppm
Output: 0-1V
Temperature range: 5-45 ℃
Warranty period: 12 months
Sample gas contact part: stainless steel
Optional:
Built in sampling pump - universal or intrinsic safety type
Portable case
Injection filter
Other accessories and consumables:
GPR-12-2000-MS2Oxygen Sensor
XLT-12-333 Acid Gas Oxygen Sensor
oxygen analyzerBattery A2244
A-2590 instrument with suction pump rechargeable battery
PWRS-1003 9V charger (220V AC)
A-1004 Sensor Cover
LCDLCD display MTR-1001
A-1095M main PCBboard
A-2166 intermittent working vacuum pump
oxygen analyzerBattery A1163
A-2166-4 consecutiveWorking vacuum pump
Oxygen sensor GPR-12-2000-MS2