GE-DRUCK DPI822 Thermocouple Calibration Instrument
GE-DRUCKDPI822 Thermocouple Calibration Instrument Detailed Information Brand: DRUCK Origin: USA GE Supplier: Shenzhen Yinfei Electronic Technology Co
Product details

Detailed information of GE-DRUCK DPI822 thermocouple calibrator

Brand: DRUCK
Origin: GE, USA
Supplier: Shenzhen Yinfei Electronic Technology Co., Ltd
the United StatesGE-DRUCK DPI822 Thermocouple Calibration InstrumentProduct Introduction
the United StatesGE-DRUCK DPI822 Thermocouple Calibration InstrumentSupplying the United States with spot goods from Shenzhen Yinfei Electronic TechnologyPrice, parameter specifications, model pictures, brand/trademark, inventory, etc. Dry body furnace Yinfei Electronics gathers spot goods, products, and various models from all over the country. Here we provide you with the United StatesAs a product sales company in China, Yinfei has prepared a large amount of spot goods for users to choose from. The following are detailed parameter specifications and other information. For more detailed tester information, you can enter "1001718" in the Baidu input box and press Enter to enter Silver Fly for viewing. This product is supplied by Shenzhen Yinfei Electronic Technology Co., Ltd., Hong. Address: Room 2217, Building A, Saige Qunxing Plaza, Huaqiang North, Futian District, Shenzhen.

DRUCK DruckerDPI822 thermocouple calibrator

When purchasing one of our testing instruments, you are also purchasing a complete testing solution.

We provide correct testing implementation recommendations to ensure that your testing results meet the standards in your industry.

We help you choose suitable accessories and fixtures to ensure the accuracy of your test results.

We will train you on the correct operation and use of it, ensuring that the process of testing products or instruments will be easy for you to operate and provide you with high-precision test results.

  • 高性能,低成本
  • Measure and simulate thermocouple signal output
  • Advanced cold end compensation technology
  • Temperature testing and maintenance
  • Transmitter calibration
  • Circuit setup and maintenance
  • Switch verification
  • Temperature detection and maintenance
  • Transmitter calibration
  • Circuit setup and maintenance
  • Switch verification

The DPI 800 series is a complete set of advanced, robust, and easy-to-use handheld instruments These instruments have high cost-effectiveness and are ideal tools for detecting and verifying many common process parameters. Advanced features and innovative technology can help you solve more application problems in a shorter amount of time and provide you with reliable data results.

Temperature testing and measurement

DPI 822 thermocouple calibrator Measuring or simulating thermocouple sensors is an ideal tool for inspecting probes, indicators, and controllers.
Unique cold end compensation technology

Almost avoids errors caused by changes in environmental temperature (under application)

Advanced Features Steps, slopes, scaling, maximum/minimum/average values, and reading retention are beneficial for system inspection and troubleshooting.

Temperature instrument and circuit maintenance

DPI 822 thermocouple calibrator Simultaneously provide thermocouple output values and milliampere measurement values for transmitter and loop maintenance.
24V power supply Charging the transmitter and control loop
Automatic switch test Capture the on/off value of the trip mechanism and conduct a quick and high-precision "safety system" inspection.
HART resistor It can be switched to the loop when needed by the HART digital communicator, thus avoiding the inconvenience of carrying a 250 Ω resistor.

IDOS flexibility

Intelligent Digital Output Sensor (IDOS) Can provide a universal pressure module with a measurement range of 10 inH2O~10000 psi (25 mbar~700 bar)
Full flexibility The IDOS module can be used with any compatible instrument. For example, the DPI 822 RTD loop calibrator can become a fully functional pressure calibrator.
Plug and Play Modules can be interchanged between instruments without the need for setup or instrument calibration.
Please refer to the IDOS UPM data sheet.
Cold end error For a change in ambient temperature of 86 ° F (30 ° C), the maximum error value is 0.4 ° F (0.2 ° C)
Thermocouple interface Mini socket

DPI 800 series universal specifications

Operating Temperature 14°F~ 122°F (-10°C~ 50°C)
storage temperature -4°F~158°F (-20°C~70°C)
humidity 0%~90%, no condensation, Def Stan 66-31, 8.6 Cat III
Shock and vibration BS EN61010:2001, Def Stan 66-31, 8.4 Cat III
Electromagnetic Compatibility BS EN61326-1:1998 + A2:2001
safety Electrical BS EN61010:2001. Pressure Equipment Directive (PED), Grade SEP. CE Mark
display Graphic LCD with backlight resolution 99999
Size (length x width x height) and weight 7.1″ x 3.3″ x 2″ (180 mm x 85 mm x 50 mm), 18 盎司 (500 g)
battery 3 AA alkaline batteries. When measuring, the working time is greater than 50 hours; Working time>10 hours when outputting 24V

For more detailed tester information, you can enter "1001718" in the Baidu input box and press Enter to enter Silver Fly for viewing. This product is supplied by Shenzhen Yinfei Electronic Technology Co., Ltd., Hong. Address: Room 2217, Building A, Saige Qunxing Plaza, Huaqiang North, Futian District, Shenzhen.