Product Introduction
Product Introduction
GC2030Plus gas chromatograph (touch screen) is a laboratory gas chromatograph developed by Tate Instruments with dedicated research and development. It adopts a 7-inch color touch screen control and a professional chromatograph UI operation interface design, which intuitively reflects the internal temperature values of the injection port, column temperature box, detector, and the values of each detector, as well as the running time. It has a one click cooling function, simple and intuitive operation, and easy to use.
This instrument is widely used in various fields such as scientific research and education, petroleum, chemical engineering, biochemistry, food safety, medicine and health, environmental monitoring, judicial investigation, etc. The instrument has high testing accuracy, good repeatability, and is trustworthy.
Product Characteristics
Product Parameters
base stem or root of plants join number |
Instrument model |
GC2030Plus |
Main purpose |
Qualitative and quantitative analysis of organic compounds (inorganic gases) |
|
Working environment requirement |
Temperature requirement: 15 ℃ -35 ℃ |
|
Humidity requirement: 25% -80% | ||
Power requirements: AC220V ± 10%, 50Hz | ||
Power requirements |
2200W |
|
External dimensions |
600×540×455mm |
|
weight |
About 60kg |
host machine |
Temperature controlled zone |
6-way independent temperature control |
circuit design |
Adopting ARM embedded design and internal CAN mode, the temperature control adopts a high-frequency feedback mechanism of 1700 times per second, resulting in higher control accuracy |
|
monitor |
7-inch color touch screen display, switching between Chinese and English, intelligent human-machine dialogue |
|
injection port |
Can be equipped with 3 injectors (filled injection port, split/non split capillary injection port) |
|
detector |
approvezuiMultiple selection with 4 detectors (FID, TCD, FPD, ECD, NPD, PID) |
|
Auxiliary sampling device |
Optional injection valve, headspace sampler, thermal analysis sampler, automatic sampler, etc |
|
Chromatography software |
Tetchrom ® The fully reverse control network chromatography workstation can automatically obtain the IP and MAC addresses of the chromatograph, and can achieve network self diagnosis. The instrument can be connected to the network to achieve remote software updates, firmware "one click updates" and other functions |
|
Connection method |
Network port connection, can also choose analog output ports such as 485, and can achieve fast communication and connection of DCS online instruments through the MUDBAS (TCP/IP) protocol |
|
Intelligent |
Equipped with automatic access to method files upon startup, self checking. When the chromatograph reaches the startup conditions, it automatically completes heating, ignition, preparation, automatic valve switching, sampling, post-processing, and uploads data results to the designated DCS, making it easy to meet project requirements for online monitoring |
|
Method storage and method sequence |
The instrument has a large capacity storage card of 8GB inside, which can store a large number of chromatographic methods; The method sequence can be freely edited to determine different projects or to implement actions such as automatic shutdown after testing, reducing the need for manual and ineffective waiting |
|
power-off protection |
The instrument adopts a power-off protection function, which automatically saves the set data at the moment of power failure, and can automatically heat up and ignite the instrument when it is powered on |
|
automation |
Supporting 8 external events, each event independently completes the required parameter settings and execution |
|
Quick function |
The instrument has quick testing functions such as one key preparation, one key cooling, one key operation, and one key ignition, greatly saving customers' ineffective waiting time |
|
expand |
4-channel input/output design, can easily start the chromatograph through external devices or external events, output mode: IO passive contact or 24V output |
column box |
Temperature rise and fall |
Equipped with rapid heating and cooling functions |
oven temperature |
5 ℃ to 450 ℃ above room temperature (up to -50 ℃ when using liquid CO2 and -99 ℃ when using liquid nitrogen) |
|
TPD |
21st level 21 platform |
|
The maximum heating rate |
120℃ / min |
|
Temperature setting accuracy |
0.1℃ |
|
precision |
0.02℃ |
|
Temperature Stability |
For every 1 ℃ change in ambient temperature, the temperature change in the column temperature chamber is less than 0.01 ℃ |
|
Cooling rate |
Reduce from 350 to 50 ℃ ≤ 8 minutes (room temperature 25 ℃) |
|
over temperature protection |
When the temperature inside the column temperature box is too high, activate the automatic protection function |
|
Maximum running time |
9999.99 minutes |
advance appearance system interconnected system |
Basic parameters |
Number of injection ports: The most capable of simultaneously installing three independent temperature controlled injection units (injection ports/injection valves) Injection port temperature range: the highest temperature is 420 ℃, with a temperature rise setting of 1 ℃ step Type of injection unit: single/double packed column injection port, split/non split injection port, wide aperture injection port |
Single/double filled column injection port |
Qualitative and quantitative analysis of organic compounds (inorganic gases) |
|
split/splitless Capillary column injection port |
Purpose: Used for injection into capillary chromatography columns, often used for trace impurity determination |
|
Injection valve |
High temperature tracing valve box: ZuiMulti controllable 4-way multi way valve, up to 225 degrees |
inspect measure implement one first |
Basic parameters |
Four independent temperature controlled detectors can be installed simultaneously. The gas in the detectors is controlled by a manual pressure control system, and the data acquisition rate of the detectors can reach up to 250Hz (4ms) |
Hydrogen flame ionization detector (FID) |
zuiHigh operating temperature: 420 ℃ Method: Dual channel method Automatic ignition function: using military grade igniters, the ignition wire adopts a non exposed design, and the service life is 100 times that of conventional ignition wires, with a 10-year warranty Detection limit: 5.0 × 10-12G/s (n-hexadecane) Baseline noise: ≤ 2 × 10-14A Baseline drift: ≤ 1 × 10-13A/30 min (after the instrument stabilizes for 2 hours) Dynamic range: 107 |
|
thermal conductivity detector (TCD) |
zuiHigh operating temperature: 300 ℃ Method: Dual arm microporous hot wire design Sensitivity: S value ≥ 8000mv.ml/mg (benzene) Baseline noise: ≤ 10UV Baseline drift: ≤ 50UV/30min Dynamic range: 105 |
|
Electron capture detector (ECD) |
zuiHigh operating temperature: 400 ° C Method: Use Ni63 source constant current method zuiSmall detection limit: ≤ 1.0 × 10-13g/s(r-666) Baseline noise: ≤ 40UV Baseline drift ≤ 100UV/30min Dynamic range: 104 |
|
Flame luminosity detector (FPD) |
zuiHigh operating temperature: 350 ° C zuiSmall detection limit: ≤ 1.4 × 10-12g/s(P) ,≤5×10-11g/s(S); Baseline noise: ≤ 20UV Baseline drift ≤ 50UV/30min Linear dynamic range: ≥ 103S,≥104P; |
colour table control make soft piece |
Tetchrom chromatography workstation |
Suitable for operating systems such as Win7 and Win10, it reads sampling data from CDF files that comply with A/A (American Society for Analysis) standards |
data acquisition |
A self-developed anti control network chromatography workstation that enables simultaneous acquisition and control of three channel data (software copyright certificate provided) |
|
Rights Management |
Can achieve three-level permission management for operation and maintenance personnel, instrument users, and equipment administrators |
|
data transmission |
By using Ethernet communication, the data throughput is faster and the bidirectional handshake frequency is higher. The chromatography system with completely independent intellectual property rights has a standard interface of MODBUS/TCP, which can be easily integrated with DCS |
|
sensitivity |
1uV*s, Dynamic range: 220 |
|
Network Communications |
Support wireless network communication connection |
|
Unmanned function |
Support various functions required for automated online monitoring, such as automatic startup, automatic temperature rise, automatic ignition, automatic bridge current opening, automatic sample collection, automatic data processing, and automatic generation of data trend charts |
|
automatic calibration |
For customized projects, automatic zeroing, calibration, calibration and other functions can be achieved, as well as scheduled calibration |
|
system safety |
Fully supports FDA-21CFR Part 11 authentication (electronic signature, resume, user password), System Applicability Testing (SST), and System Authentication Tools (IQ/OQ) |
|
Batch processing function |
The batch processing function enables the control of the instrument, automatic sampler sequence acquisition, automatic integration correction, and output report to be completed in one go, simplifying daily tedious analysis |
|
data comparison |
Powerful post-processing functions, including spectrum comparison, recalibration, and data input and output, are all available. "Special Attention Online" can obtain analysis results online without waiting for the end of data collection |
Software Interface
The PC network version chromatography workstation software can operate the instrument (supporting 253 units), realizing program control of the instrument's injection port, column temperature box, and detector temperature rise and fall. Under the condition that the customer is equipped with an automatic injection valve (or automatic sampler), it is possible to achieve a series of testing processes such as unmanned instrument operation, automatic heating and ignition of the instrument, automatic loading method, and automatic calculation of test results
Chromatogram peak chart