Shanghai Taitai Ruijie Information Technology Co., Ltd
Home>Products>GC2030 Gas Chromatography Classic (Key Press)
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    15026928007
  • Address
    Room 602, Building F, Minggu Science and Technology Park, No. 7001 Zhongchun Road, Minhang District, Shanghai
Contact Now
GC2030 Gas Chromatography Classic (Key Press)
GC2030 Gas Chromatography Classic (Key Press)
Product details

Product Introduction


Product Introduction

蓝色线条.jpg

Gas chromatograph is a high-precision scientific instrument for analyzing and detecting various components in a mixed gas. It uses gases such as nitrogen, hydrogen, helium, argon, etc. as carrier gases to qualitatively and quantitatively analyze various components in the mixed gas. GC2030Classic gas chromatograph (button type) is an economical and practical gas chromatograph developed by Tate Instruments through dedicated research and development. It adopts a control system of "LCD screen+buttons", with a simple and intuitive interface operation, making it convenient for users to use.

This instrument is widely used in various fields such as scientific research and education, petroleum, chemical engineering, biochemistry, food safety, medicine and health, environmental monitoring, judicial investigation, etc. The instrument has high testing accuracy, good repeatability, and is trustworthy.


Product Parameters

蓝色线条.jpg


base

stem or root of plants

join

number

Instrument model

GC2030Classic

Main purpose

Qualitative and quantitative analysis of organic compounds (inorganic gases)

Working environment requirement

Temperature requirement: 15 ℃ -35 ℃

Humidity requirement: 25% -80%

Power requirements: AC220V ± 10%, 50Hz

Power requirements

0.01℃

External dimensions

600×540×450mm

weight

About 60kg


host

machine

Temperature controlled zone

6-way independent temperature control

circuit design

Adopting ARM embedded design and internal CAN mode, the temperature control adopts a high-frequency feedback mechanism of 1700 times per second, resulting in higher control accuracy

monitor

3.5-inch blue LCD screen+button control panel

injection port

Can be equipped with 3 injectors (filled injection port, split/non split capillary injection port)

detector

Up to 4 detectors (FID, TCD, FPD, ECD, NPD, PID) can be optionally selected

Auxiliary sampling device

Optional injection valve, headspace sampler, thermal analysis sampler, automatic sampler, etc

Chromatography software

Tetchrom ® The fully reverse control network chromatography workstation can automatically obtain the IP and MAC addresses of the chromatograph, and can achieve network self diagnosis. The instrument can be connected to the network to achieve remote software updates, firmware "one click updates" and other functions

Connection method

Network port connection, can also choose analog output ports such as 485, and can achieve fast communication and connection of DCS online instruments through the MUDBAS (TCP/IP) protocol

Intelligent

Equipped with automatic access to method files upon startup, self checking. When the chromatograph reaches the startup conditions, it automatically completes heating, ignition, preparation, automatic valve switching, sampling, post-processing, and uploads data results to the designated DCS, making it easy to meet project requirements for online monitoring

Method storage and method sequence

The instrument has a large capacity storage card of 8GB inside, which can store a large number of chromatographic methods; The method sequence can be freely edited to determine different projects or to implement actions such as automatic shutdown after testing, reducing the need for manual and ineffective waiting

power-off protection

The instrument adopts a power-off protection function, which automatically saves the set data at the moment of power failure, and can automatically heat up and ignite the instrument when it is powered on

automation

Supporting 8 external events, each event independently completes the required parameter settings and execution

Quick function

The instrument has quick testing functions such as one key preparation, one key cooling, one key operation, and one key ignition, greatly saving customers' ineffective waiting time

expand

Designed with up to 4 input/output channels, it is easy to start the chromatograph or external events through external devices. Output modes: IO passive contacts or 24V output


column

box

Temperature rise and fall

Equipped with rapid heating and cooling functions

oven temperature

5 ℃ to 450 ℃ above room temperature (up to -50 ℃ when using liquid CO2 and -99 ℃ when using liquid nitrogen)

TPD

16 levels and 16 platforms

maximum rate

120℃ / min

Temperature setting accuracy

0.1℃

precision

0.02℃

Temperature Stability

For every 1 ℃ change in ambient temperature, the temperature change in the column temperature chamber is less than 0.01 ℃

Cooling rate

Reduce from 350 to 50 ℃ ≤ 8 minutes (room temperature 25 ℃)

over temperature protection

When the temperature inside the column temperature box is too high, activate the automatic protection function

Maximum running time

9999.99 minutes


advance

appearance

system

interconnected system

Basic parameters

Number of injection ports: Up to three independent temperature controlled injection units (injection ports/injection valves) can be installed simultaneously

Temperature range of injection port: maximum temperature of 420 ℃, temperature rise set at 1 ℃ step

Type of injection unit: single/double packed column injection port, split/non split injection port, wide aperture injection port

Single/double filled column

injection port

Qualitative and quantitative analysis of organic compounds (inorganic gases)

split/splitless

Capillary column injection port

Purpose: Used for injection into capillary chromatography columns, often used for trace impurity determination

Injection valve

High temperature tracing valve box: can control up to 4 multi way valves, up to 225 degrees Celsius


inspect

measure

implement

one

first

Basic parameters

Four independent temperature controlled detectors can be installed simultaneously, and the gas in the detectors is controlled by a manual pressure control system. The data acquisition rate of the detectors can reach up to 250Hz (4ms)

Hydrogen flame ionization

detector

(FID)

Maximum operating temperature: 420 ℃

Method: Dual channel method

Automatic ignition function: using military grade igniters, the ignition wire adopts a non exposed design, and the service life is 100 times that of conventional ignition wires, with a 10-year warranty

Detection limit: 5.0 × 10-12G/s (n-hexadecane)

Baseline noise: ≤ 2 × 10-14A

Baseline drift: ≤ 1 × 10-13A/30 min (after the instrument stabilizes for 2 hours)

Dynamic range: 107

thermal conductivity detector

(TCD)

Maximum operating temperature: 300 ℃

Method: Dual arm microporous hot wire design

Sensitivity: S value ≥ 8000mv.ml/mg (benzene)

Baseline noise: ≤ 10UV

Baseline drift: ≤ 50UV/30min

Dynamic range: 105

Electron capture

detector

(ECD)

Maximum operating temperature: 400 ° C

Method: Use Ni63 source constant current method

Minimum detection limit: ≤ 1.0 × 10-13g/s(r-666)

Baseline noise: ≤ 40UV

Baseline drift ≤ 100UV/30min

Dynamic range: 104

Flame luminosity

detector

(FPD)

Maximum operating temperature: 350 ° C

Minimum detection limit: ≤ 1.4 × 10-12g/s(P) ,≤5×10-11g/s(S);

Baseline noise: ≤ 20UV

Baseline drift ≤ 50UV/30min

Linear dynamic range: ≥ 103S,≥104P;


colour

table

control

make

soft

piece

Tetchrom chromatography

workstation

Suitable for operating systems such as Win7 and Win10, it reads sampling data from CDF files that comply with A/A (American Society for Analysis) standards

data acquisition

A self-developed anti control network chromatography workstation that enables simultaneous acquisition and control of three channel data (software copyright certificate provided)

Rights Management

Can achieve three-level permission management for operation and maintenance personnel, instrument users, and equipment administrators

data transmission

By using Ethernet communication, the data throughput is faster and the bidirectional handshake frequency is higher. The chromatography system with completely independent intellectual property rights has a standard interface of MODBUS/TCP, which can be easily integrated with DCS

sensitivity

1uV*s, Dynamic range: 220

Network Communications

Support wireless network communication connection

Unmanned function

Support various functions required for automated online monitoring, such as automatic startup, automatic temperature rise, automatic ignition, automatic bridge current opening, automatic sample collection, automatic data processing, and automatic generation of data trend charts

automatic calibration

For customized projects, automatic zeroing, calibration, calibration and other functions can be achieved, as well as scheduled calibration

system safety

Fully supports FDA-21CFR Part 11 authentication (electronic signature, resume, user password), System Applicability Testing (SST), and System Authentication Tools (IQ/OQ)

Batch processing function

The batch processing function enables the control of the instrument, automatic sampler sequence acquisition, automatic integration correction, and output report to be completed in one go, simplifying daily tedious analysis

data comparison

Powerful post-processing functions, including spectrum comparison, recalibration, and data input and output, are all available. "Special Attention Online" can obtain analysis results online without waiting for the end of data collection


Product Characteristics

蓝色线条.jpg

1. Reasonably construct the gas source pathway and internal structure inside the instrument, make the layout of components more reasonable, reduce signal interference from components, improve detection accuracy, and ensure excellent stability and durability of the equipment.

2. The instrument has excellent repeatability. Under the experimental conditions of using an automatic sampler for injection, the repeatability error of the instrument test can reach 2%, which is better than the 3% specified by the national standard.

3. The column temperature box adopts a six channel independent temperature control system, an automatic rear door opening system, a 21 stage 21 platform program temperature rise, fast temperature rise/fall speed, and a temperature control accuracy of 0.1 ℃, making the equipment capable of large-scale sample analysis.

4. The whole machine adopts modular design and can work in parallel with multiple processors. It includes 2 types of injection port modules (capillary column injection port and packed column injection port), 5 types of high-performance detector modules (FID, TCD, ECD, FPD, and NPD), and can be installed with multiple injection ports and detector modules according to customer requirements (customizable six way valve, ten way valve gas injector, top air injector, thermal analysis injector, cracking furnace injector, methane conversion furnace). It supports up to 3 sets of injection ports and 4 types of detectors, making it convenient for users to upgrade and modify in the later stage.

5. It can be directly connected to the computer and operated through the PC network version chromatography workstation software (supporting up to 253 units) to achieve program control of the instrument's injection port, column temperature box, and detector temperature rise and fall. Under the condition that the customer is equipped with an automatic injection valve (or automatic sampler), it is possible to achieve a series of testing processes such as unmanned instrument operation, automatic temperature rise and ignition of the instrument, automatic loading method, and automatic calculation of test results, meeting the requirements of online testing.

6. The exclusive Internet of Things chromatograph technology, with built-in IP protocol stack, can upload test data to the computer of the on-site laboratory, department heads and superior leaders through the corporate LAN or the Internet, which is convenient for each department to monitor the operation of the instrument and test results in real time. It can directly connect with the manufacturer through the Internet to realize remote diagnosis of gas chromatograph, remote program update, etc.

7. It can be integrated with automatic samplers produced by multiple domestic and foreign manufacturers, such as Shimadzu's AOC-20i and Italy's HTA company's HT series high-efficiency gas-phase liquid automatic sampler, to reduce instrument detection errors caused by human factors and improve instrument testing accuracy.


Software Interface

蓝色线条.jpg

The PC based network version chromatography workstation software is used to operate the instrument (supporting up to 253 units), achieving program control of the instrument's injection port, column temperature box, and detector temperature rise and fall. Under the condition that the customer is equipped with an automatic injection valve (or automatic sampler), it is possible to achieve a series of testing processes such as unmanned instrument operation, automatic heating and ignition of the instrument, automatic loading method, and automatic calculation of test results

色谱工作站.jpg


Chromatogram peak chart

蓝色线条.jpg


非甲烷总烃和苯系物色谱峰图

白酒组分色谱峰图

化工溶剂色谱峰图

香料香精色谱峰图

油墨溶剂残留色谱峰图

异辛烷色谱峰图


Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!