Achieve excellent operability and functionality at low cost
characteristic
Easy to use 2 digital screens
Equipped with two digital screens, it can simultaneously confirm the reference value, input light amount, and perform various settings with strong operability. |
|
Reduce processing preparation time and maintenance model by using commercially available connectors
By using commercially available connectors, the cost of connector processing and preparation time after purchasing sensors can be significantly reduced. It can make the digital pressure sensor DP-100 series, micro photoelectric sensor PM-64 series, and connector components universal. |
|
Effective space saving with a slender size of 9mm in width
A slender specification with a width of 9mm. Thinner than existing fiber optic sensors. The difference is not significant when using a single unit, but it becomes very noticeable when using multiple units. |
|
Improve long-term stability
The projection component adopts the standard specification of "4-element light-emitting diode" for Panasonic's Shenshi digital fiber optic sensor. Can ensure long-term stable light output. |
|
Using a clear operating system to achieve simple operations
Adopting the operating system of the highly acclaimed digital pressure sensor DP-100 since its launch. According to the level of the setting content, it is clearly divided into three types: "RUN mode", "SET mode", and "PRO mode", and the setting operation is simple and clear.
Easy to set up quick code input function [RUN mode]
Simply enter the pre-set "code (number)" to set the sensor. Even if the settings are changed incorrectly, simply enter the code to immediately restore normal operation. When using the phone, it is also possible to confirm smoothly through the "code (number)". For overseas customers, technical support can also be easily provided. |
|
Use the ON/OFF button for simple teaching [SET mode]
Simply press the ON button at the desired detection location or state, and press the OFF button in other situations to set up the teaching. Can save time in distinguishing between ON when entering light and ON when blocking light.
Teaching can be conducted even without workpieces. Limited teaching function
By teaching the state of no workpiece (stable light input), a "reference value" can be set. Convenient for detecting background objects and detecting small objects. In addition, teaching can be conducted through external input. |
|
Eliminate deviation in light input display with GETA function [PRO mode]
Even with the same testing, there are deviations in the digital values of each fiber amplifier. Although the testing itself is not a problem, it may also cause concern for the operators. Through the GETA function, it can be corrected to any value, thus eliminating display deviations and making it easy to create job instructions. |
|
Save maintenance time, equipment benchmark value tracking cycle setting function [PRO mode]
To track changes in the amount of light input caused by long-term environmental changes (such as dust), the amount of light input can be confirmed at any cycle and the reference value can be automatically reset. This helps to reduce maintenance hours. |
|
Stable detection of small objects and transparent bodies with adjustable light projection [SET mode]
When the light level reaches saturation during close range detection, detection of transparent or small objects, etc., the amount of light projected by the sensor can be reduced to achieve stable detection. By using this function, it is also easy to set the detection that previously required changing the fiber and setting the distance. In addition, in the past, only one level of dimming could be set, but now there are four types of settings that include three levels and automatic settings. (Starting from the portion produced in December 2007.) |
|
Can prevent mutual interference and confirm the projection flash in the setting [SET mode]
The maximum number of units that can prevent mutual interference for the standard FX-101 □ and long-distance FX-102 □ are 3 and 4, respectively. When setting anti-interference, the projection light will flash, so the set fiber optic is clear at a glance. In addition, there is no need to install amplifiers as closely as before, even if there is a distance between the amplifiers, they can still function. |
|
Sensors can be set externally [PRO mode]
Projection stop, limited teaching/fully automatic teaching/2-point teaching, ECO and light input testing can be set through external input. In addition, benchmark values that need to be taught can be stored. (Note 1) (Note 1): Based on products produced in December 2007, adjustments have been made in the storage of the light input test and benchmark values. |
|
Digital display reversal setting function [PRO mode]
The direction of the digital display can be reversed according to the installation direction of the amplifier. |
|
Reference value margin setting function with clear detection margin [PRO mode]
The residual amount relative to the reference value of the current light input can be confirmed based on the flashing of the digital display screen. |
|
Reduce working hours, human error setting replication function [PRO mode]
By installing each fiber optic sensor onto the main fiber optic sensor, the settings of the main sensor can be replicated through data communication. When setting the same settings for multiple fiber optic sensors, it can prevent faults caused by incorrect settings. When changing the design of the device, only a slight modification to the operation instructions is needed.
Free installation without accessories
When installing DIN rails, they can be directly installed through the through holes on the side of the body. When directly installed, only one unit can be set up or installed on the operating part, and accurate installation can be carried out without deviation. |
|
Standard and long-distance products are available
There are two types of products available, standard and long-distance, with different reaction times and detection distances. It can be selected for use according to its intended purpose. |
|
Can save power consumption
After setting, if no key operation is performed for about 20 seconds, the digital display screen will turn off and the power consumption will be controlled below about 600mW. (Below 720mW when illuminated)