VIP member
Factory test of water pump power performance (single station)
Host introduction: Factory test of water pump power performance (single station), single and three-phase, flow rate 20T/H \ 0.5MPA
Product details
1、 Customer Products
|
Hot water pump production testing equipment (one G1.5)
|
|
2、 Customer demand
|
Factory test of water pump power performance (single station)
|
|
3、 Product parameters
|
Single and three-phase, flow rate 20T/H \ \ 0.5MPA
|
|
4、 Mechanical
|
Quick pneumatic installation of water pump and auxiliary water tank pipeline
|
|
5、 Electrical
|
DJC-1300 motor driven water pump performance test cabinet (40A sleeper cabinet)
|
|
6、 Software functional testing
|
Steady state performance test
|
Pneumatic clamping (X-Y-Z)
|
load
|
||
Manual inspection of pump head pressure (≥ 1.0MPa) leakage
|
||
7、 Reference standards
|
GB/T3216-2005,GB/T12785-2002,QC/T288.1-2001
|
Serial Number
|
physical property
|
subsystem
|
Equipment name
|
technical requirement
|
Specification and model
|
Number
|
notes
|
1
|
machinery
|
Pipeline device
|
1 stainless steel square water tank
|
500/100(L)
|
|
2 pieces
|
Control the water level of the upper and lower water tanks
|
2
|
2 Pump specific card frame and platform
|
Stainless steel channel steel
|
Longmen frame
|
1 set
|
According to customer samples
|
||
3
|
3 Stainless steel hoses and pipelines
|
|
DN40
|
1 set
|
Pipeline joint
|
||
4
|
4 Aluminum profile frame and door panel
|
stainless steel
|
|
1 set
|
|
||
5
|
5 Gas liquid cylinder and gas meter
|
Gas liquid thrust 1T
|
DN100
|
2 sets
|
SNS
|
||
6
|
6 Manual Push Rod and Guide Gauge
|
Adjusting the height
|
X-Y-Z
|
3 sets
|
|
||
7
|
7 Electric pressure test pump
|
Adjustable pressure plunger pump
|
Haili D-Y2
|
1 piece
|
2.0MPA
|
||
8
|
8 stainless steel solenoid valve
|
|
DN40
|
2 pieces
|
One DN15
|
||
9
|
electrical
|
Cabinet 1
|
1 Instrument testing cabinet
|
Can accommodate all-in-one machines, including contactors, electrical switches, wiring, etc
|
DJC-1300
|
1 unit
|
|
10
|
2 measurement units
|
Three phase electrical parameter measuring instrument
|
Voltage 500V, current 40A, power, power factor, frequency, accuracy level 0.5
|
GDW3001A
|
1 unit
|
Single and three-phase
|
|
11
|
2 Pressure transmitters (outlet)
|
1.5MPa
|
BTL-900
|
1 unit
|
|
||
12
|
3 Electromagnetic flow sensors
|
40mm(0.4-18m3/h), Accuracy level 0.5
|
DN40
|
1 set
|
|
||
13
|
3 Information supporting units
|
5 Information Research Integrated Machine
|
17 inch embedded, multi serial port, quad core low-power processor
|
HMT-1702T
|
1 unit
|
|
|
14
|
Upper computer software
|
1. Steady state performance test
|
load
|
Test voltage, current, and power
Test voltage, current, power, flow rate, and pressure
|
VB1.0
|
1 set
|
Including expansion card
|
15
|
power supply
|
POWER
|
AC regulated power supply
|
Provide power to the tested water pump
|
5KVA
|
1 unit
|
|
16
|
Installation materials
|
cable
|
Power cable
|
|
|
1 set
|
|
17
|
Freight and on-site debugging
|
|
|
Once
|
|
Online inquiry