FP-30MK2 (C) Formaldehyde Analyzer (RIKEN, Japan)
Technical parameters:
Model number |
FP-30MK2(C) |
|
Detecting target gas |
formaldehyde |
|
Detection Principle |
Test paper photoelectric photometry method |
|
Measurement range |
TAB No.008 |
TAB No.009 |
0.000-0.50mg/m3 (not noticing that 0.02mg/m3 shows<0.02mg/m3) |
0.00~1.25mg/m3 (Note that 0.02mg/m3 shows<0.02mg/m3) |
|
Display units |
0.01mg/m3 |
0.025mg/m3 |
Time |
1800s (30 minutes) |
900S (15 minutes) |
Display mode |
LCD digital display |
|
detection |
Pump suction type, cumulative value over time suction flow rate: 0.5L/min |
|
Usage environment |
-10 ° to+40 ° below 90% RH (non condensing) |
|
Storage function |
Store 99 detection records (automatically stored after detection) |
|
Fault Alarm |
Low battery voltage, poor sensor, poor pump contact, machine system errors, abnormal temperature, etc |
|
Power supply |
Four 5th alkaline batteries |
|
Continuous working hours |
About 12 hours |
|
outline dimension |
80*150*40mm |
|
Weight |
250g , , |
|
function |
Automatic memory data logger, clock function |
|
standard configuration |
Host, 20 TAB tablets, 4 No. 5 batteries, bracelet, instruction manual, etc |
|
Select accessories |
Regularly exchanged filters and data recording system software |
FP-30MK2 (C) Formaldehyde Analyzer (RIKEN, Japan)
Technical parameters:
Model number |
FP-30MK2(C) |
|
Detecting target gas |
formaldehyde |
|
Detection Principle |
Test paper photoelectric photometry method |
|
Measurement range |
TAB No.008 |
TAB No.009 |
0.000-0.50mg/m3 (not noticing that 0.02mg/m3 shows<0.02mg/m3) |
0.00~1.25mg/m3 (Note that 0.02mg/m3 shows<0.02mg/m3) |
|
Display units |
0.01mg/m3 |
0.025mg/m3 |
Time |
1800s (30 minutes) |
900S (15 minutes) |
Display mode |
LCD digital display |
|
detection |
Pump suction type, cumulative value over time suction flow rate: 0.5L/min |
|
Usage environment |
-10 ° to+40 ° below 90% RH (non condensing) |
|
Storage function |
Store 99 detection records (automatically stored after detection) |
|
Fault Alarm |
Low battery voltage, poor sensor, poor pump contact, machine system errors, abnormal temperature, etc |
|
Power supply |
Four 5th alkaline batteries |
|
Continuous working hours |
About 12 hours |
|
outline dimension |
80*150*40mm |
|
Weight |
250g , , |
|
function |
Automatic memory data logger, clock function |
|
Standard configuration |
Host, 20 TAB tablets, 4 No. 5 batteries, bracelet, instruction manual, etc |
|
Select accessories |
Regularly exchanged filters and data recording system software
|