FBM-160/FBM-100A fluoride ion concentration analyzer
Product features:
Using the ISE (ion selective electrode) principle, it has good selectivity for fluoride ion measurement and can replace the electrode membrane
There are multiple installation methods for sensor sheaths to meet the requirements of different occasions
The rainproof structure design of the controller can be installed on-site through pipelines or wall mounting. Easy to install, easy to set up and operate
Fluorine ion composite electrode, does not consume reagentsFBM-160/FBM-100A fluoride ion concentration analyzer
● Adopting unfilled reference electrode and porous fluorocarbon resin for salt bridge, with strong anti pollution ability
The instrument has a self diagnostic function
● Can set 4-point alarm output
TECHNICAL INDEX | ||
---|---|---|
measuring range | 0~99.9mg/L,0~999mg/L,0~9990mg/L | |
Temperature output | 0.0~50.0 ℃ (FBM-160 only) | |
Instrument characteristics | Linear: | ± 8% FS (controller) |
Reproducibility: | ± 5% FS (controller) | |
90% response time: | Within 60 seconds | |
Analog Output | DC 4~20mA (impedance 650 Ω, isolated output) | |
Analog output range | The measurement range above 1/10FS can be arbitrarily set | |
Factory settings: | 0.0~20.0 mgl/L 0~200 mgl/L 0~2000 mgl/L |
|
Digital Output | RS-232C (optional) | |
ALARM IN | 4 points can be set | |
Power requirements | AC 90~264V,50/60Hz | |
environmental condition | Outdoor installation; Temperature and humidity: -20~55 ℃, below 95% RH | |
Installation method | FBM-160:50A pipeline or wall mounted or bracket installation | |
FBM-100A: Indoor panel installation, DIN 92 | ||
protection grade | FBM-160:IP65 (FBM-100A:IP30) | |
Sample conditions | pH: 4~9pH | |
temperature | 0~40 ℃ (no icing) | |
conductivity | Zui 50ms/m (500 μ S/cm) | |
velocity of flow | 0.01~0.2m/S | |
Coexisting components |
Does not contain a large amount of substances such as calcium, aluminum, iron, etc
|
Controller model
FBM160-0-AAA0AA0B (0.0~99.9mg/L, wiring G1/2, 50A)
FBM160-0-BA0AA0B (0~999mg/L, wiring G1/2, 50A)
FBM160-0-CA0AA0B (0~9999mg/L, wiring G1/2, 50A)
FBM100A-0-A0B (0.0~99.9mg/L, wiring G1/2)
FBM100A-0-B0B (0~999mg/L, wiring G1/2)
FBM100A-0-C0B<(0~9999mg/L, wiring G1/2)
Note: The above models do not include RS-232. If you have any other requirements, please inquire separately.
Immersion installation - electrode bracket
HCD70C-3-400A010 (PVC material, length 2m)
HCD70F-3-400A010 (PVDF material, 2m long)
HCD76-3-400A010 (PP material, length 2m)
Note: The bracket length is available from 0.5 to 4 meters. Please inquire about the model separately
Circulating installation - circulating pool
HCD82-0-1B (SUS316 material, Rc1/2 connection)
HCD86-1-11B (PP material, Rc1/2 connection)
HCD86-1-21B (PVC material, Rc1/2 connection)
Fluoride ion selective electrode
ELCP-81-5F (5-meter cable) ELCP-81-10F (10 meter cable)
spare parts
Electrode replacement film: 7208L
Fluoride ion standard solution (F-1000mg/L, 500mL): 143F077 ion strength
Regulator (pH5-AB, 500mL): 143A053