Electronic chain transmission window
As an auxiliary equipment in clean rooms, transfer windows are mainly used for the transfer of small items between clean areas and clean areas, non cl
Product details
  • Product Name: Electronic chain transmission window
  • Product Code: 1082608396348837888

As an auxiliary equipment in clean rooms, transfer windows are mainly used for the transfer of small items between clean areas and clean areas, non clean areas and clean areas, in order to reduce the number of door openings in clean rooms and minimize pollution in clean areas. Transfer windows are widely used in micro technology, biological laboratories, pharmaceutical factories, hospitals, food processing industries LCD、 Electronic factories and all other places that require air purification. Transfer window is an auxiliary equipment in clean rooms, mainly used for the transfer of small items between clean areas and between clean areas and non clean areas, in order to reduce the number of times the clean room is opened and minimize pollution to the clean room

As an auxiliary equipment in clean rooms, transfer windows are mainly used for the transfer of small items between clean areas and clean areas, non clean areas and clean areas, in order to reduce the number of door openings in clean rooms and minimize pollution in clean areas. Transfer windows are widely used in micro technology, biological laboratories, pharmaceutical factories, hospitals, food processing industries LCD、 Electronic factories and all other places that require air purification.

Transfer window is an auxiliary equipment in clean rooms, mainly used for the transfer of small items between clean areas and between clean areas and non clean areas, in order to reduce the number of times the clean room is opened and minimize pollution to the clean room. The transfer window is made of stainless steel plate, which is flat and smooth. The two doors are interlocked to effectively prevent cross contamination, equipped with electronic or mechanical interlocking devices and equipped with ultraviolet sterilization lamps.

Transfer window purpose:

A device for transferring items set up in the clean area to reduce the number of door openings, mainly used for the transfer of small items in clean rooms of different levels or between clean and non clean areas, to prevent unclean air from entering the clean room during material transfer, and to reduce the degree of pollution in the clean room.

Instructions for using the transfer window:

  The transfer window is managed according to the cleanliness level of the higher-level clean area connected to it.

  For example, the transfer window connecting the coding room and the filling room should be managed according to the requirements of the filling room. After work, the clean area operator is responsible for wiping the internal surfaces of the transfer window clean and turning on the ultraviolet sterilization lamp30minute.

1 Materials entering and leaving the clean area must be strictly separated from the pedestrian flow channel and accessed through the dedicated material channel in the production workshop.

2 When materials enter, the process leader of the preparation team organizes personnel to unpack or clean the surface of the raw materials, and then sends them to the temporary storage room of the workshop through the transfer window; After removing the outer packaging from the outer temporary storage room, the inner packaging materials are sent into the inner packaging room through the transfer window. The workshop coordinator and the person in charge of the preparation and internal packaging processes handle the handover of materials.

3 When passing through the transmission window, it is necessary to strictly follow the rule of "one opening and one closing" for the inner and outer doors of the transmission window, and the two doors cannot be opened at the same time. Open the outer door to put the materials in, then close the door first, then open the inner door to take out the materials, and finally close the door, and repeat this process.

4 When materials are sent out from the clean area, they should be transported to the relevant material intermediate station first, and then removed from the clean area according to the reverse procedure of the materials entering.

5 All semi-finished products must be transported from the clean area to the external temporary storage room through the transfer window, and then transferred to the external packaging room through the logistics channel.

6 Materials and waste that are highly prone to pollution should be transported from their dedicated transfer windows to non clean areas.

7 After the completion of material entry and exit, the cleanliness of each cleaning room or intermediate station and the transfer window should be cleaned in a timely manner. The internal and external passage doors of the transfer window should be closed, and cleaning and disinfection work should be done well.

Design features of transfer window:

1.The surface of the box adopts two types: cold plate spray coating or all stainless steel plate, with a beautiful appearance.
2. The workspace is made of 304 stainless steel plate, which is flat, smooth, and wear-resistant.
3.
Mechanical or electronic interlocking devices are installed on both sides of the doors to prevent them from being in the open state at the same time.
4. The transfer window is equipped with a dedicated sealing strip to ensure airtightness.