HT2100HAs a professional manufacturer of automatic samplers in ItalyHTAThe company's products adhere to the principle ofHT200HseriesHeadspaceExcellent and reliable injection technology of automatic samplerAnd low-cost maintenance technology, Zui offers a wide range of services14Automated gas chromatography analysis of samples without interruption or human supervision.Compared with the old model product, it has added multiple improvement features:
★AppearanceElegant and generous, StructureMore concise、compactLightweight;
★Rotating injection method, does not occupy the injection portTaking into account manual injection;
★It has the function of a dual tower automatic sampler for sequential automatic injection of two sample ports;
Heating the maximum limit saves time;
★Using inert gas for purging, there will be no cross contamination of the sample;
★The phenomenon of absorption of certain samples caused by the absence of transmission pipelines, and the absence of transmission pipelines
The situation where the peak becomes wider due to excessive length;
★System integrity testing (headspace bottle leak detection testing) technology,Ensure the reliability of data;
★injectorcontrolsoftwareHTAAutosampler MangerSupport networked control technology,
conform toFDA 21CFR Part11Electronic signature authentication standards;
★Accurate positioning and precise stepper motor to ensure no bending of the needle phenomenon;
★Seamless compatibility with various gas chromatographs;
★IQ/OQ/PQSupport services that comply withGLP/FDAVerification Specification.
Technical specifications:
Number of samples | 14A(10/20mLHeadspace bottle) | Sample injectionNeedle temperature | 40~150℃ |
injectionNeedle capacity | standard configuration2.5mL,1/5mLchoose and buy | Sample heating box | 1、heating1A sample bottle |
injectionvolume | The least achievable0.01mL | | 2、Temperature setting40~150℃ |
injectionspeed | 0.5~100mL/min | | 3、heating time0~999divide |
injectionbalancedelay | 0~60second | | 4、shockCycle periodon/off 0~9.9branch |
Cleaning gas | Inert gas(Nitrogen or helium gas) | Multiple extraction mode | Repeatedly drawcarryMethod, frequencymanyextend15second |
compatibility | Collaborate with various gas-phase manufacturers(Domestic or imported)Seamless compatibility, sample tray can be freely changed to the leftsideOr on the right. | ||
software | HTA Autosampler Manager Basic version(standard configuration) | ||
Chromatography workstation | Clarity,Agilent EZChrom Elite,Thermo ChromQuest |