main features
●The electric energy meter adopts LCD display, which can be used for parameter query, setting, etc; It has functions such as real-time voltage and current measurement, real-time power metering, abnormal power supply quality alarm, and information exchange.
●It is a powerful, safe and reliable three-phase four circuit measurement and control instrument, which can be widely used in communication base stations, power systems, environmental detection, low-voltage distribution and other fields.
●RS-485 communication interface with industrial standards, supporting YD/T1363 protocol; It has telemetry, remote signaling, and remote control functions, with 1 DO interface and 7 DI interfaces (3 live wire detection interfaces and 4 dry node detection interfaces), voltage and frequency limit alarm, alarm, and communication prompt.
●It can record 5120 historical data with an interval of 15 minutes, 1024 historical data at midnight every day, 256 daily meter reading data, and 512 historical alarms.
PRODUCT FUNCTION
●Real time electrical parameter measurement
Real time measurement of three-phase voltage, phase separation current of each circuit, zero sequence current of each circuit, phase separation and total active power of each circuit, phase separation and total reactive power of each circuit, phase separation and total power factor of each circuit, and frequency.
●Real time energy metering
Real time measurement of total active energy in the forward direction, total active energy in the reverse direction, total reactive energy in the forward direction, and total reactive energy in the reverse direction for each of the four circuits; Phase separated active energy and phase separated reactive energy;
●call the police
A total of 10 alarms were detected, including power outage alarm, oil engine power supply alarm, A/B/C three-phase voltage limit exceeding alarm (too low, too high, too high, phase loss), frequency limit exceeding alarm (too low, too high), lightning arrester fault alarm, lightning arrester air disconnection alarm, phase sequence error, and smart meter fault alarm. Among them, voltage phase loss refers to a situation in a three-phase power supply system where the voltage of a certain phase is lower than 60% of the lower limit of the reference voltage. This product has a voltage of 132V, and the load current is less than the starting current.
When a new alarm is generated, there will be flashing prompts and LED prompts for the alarm item on the LCD display. Press any key to display the first alarm item, press the "" or "" key to display the next alarm item, press the "ESC" key to return to the normal data display interface, or automatically switch to the loop display interface after a certain period of time (default 30 seconds).
Alarm data can also be queried locally, as shown in the button display interface in Table 5.4. For example, first press the "ESC" key. When the word "Addr 1" appears, press the "ENT" key, then press the "" or "" key. When the word "Err" appears, press the "ENT" key to enter the alarm options interface. You can use the "" or "" key to query the local alarms. The specific alarm meanings are detailed in Table 5.4.
●Corresponding relationship between alarm items and terminals
Alarm item terminal type terminal number abnormality
City power outage alarm Err 1-E0 wet nodes 5,6 have no power
Oil engine power supply alarm Err 2-E1 7,8 has power
SPD air disconnect alarm Err 8-05 9,10 no power
SPD fault alarm Err 7-E2 dry node 20,21 disconnected
●Switch quantity detection
A total of 7 switch signals were tested, and 3 live line tests were conducted to detect the presence of electricity in the mains, the presence of electricity in the oil engine, and the disconnection of the lightning arrester; The 4-way dry node detection corresponds to the first dry node, the status of the mains circuit breaker, the status of the oil engine circuit breaker, and the fault detection of the lightning arrester.
●Daily data storage and reading for meter reading
Supports up to 256 meter reading day data storage and reading, and can set the meter reading day time point. Store the total active energy, total active power, and A/B/C three-phase current of each circuit.
●Timed freezing storage and reading
The maximum storage has been frozen the last 5120 times, with a default freezing interval of 15 minutes. Store the total active energy, total active power, and A/B/C three-phase current of each circuit.
●Daily frozen data storage and retrieval
The maximum storage capacity has been frozen for the past 1024 days, and the default freezing time is midnight every day; It can freeze the total active energy, total active power, and A/B/C three-phase current of each circuit.
●Alarm storage
Maximum storage of the latest 512 alarm data, using real-time alarm storage.
●Monthly frozen energy storage and reading
Freeze 24 months of electricity data.
●rs485 communication
Two wire RS485 interface, baud rates can be set to 1200, 2400, 4800, 9600, 19200, verification methods can be set to n 8 1, o 8 1, e 8 1, n 8 2, supporting YD/T1363 protocol.
performance parameter
|
performance |
parameter |
||
|
transport enter measure measure apparent show |
voltage |
range |
220V |
|
accuracy |
RMSaccuracy:0.5level |
||
|
electric current |
range |
100A |
|
|
transformation ratio |
1 |
||
|
accuracy |
RMSaccuracy:0.5level |
||
|
input |
Terminal connection |
||
|
frequency |
Error:0.02HzRange:40~70Hz. |
||
|
active power |
Active accuracy: 1Grade; |
||
|
reactive power |
Reactive power accuracy:2Grade; |
||
|
Power factor |
Power factor accuracy: Error less than0.02 |
||
|
electric energy |
active electrical energy |
Accuracy:1level |
|
|
reactive energy |
Accuracy:2level |
||
|
electricity source |
power supply |
AC85~264V/DC100~400VperhapsDC36~75V(Optional) |
|
|
power consumption |
<2.5W |
||
|
transport go out approve weave Cheng |
open up or clear out by poking or jabbing interrogate |
output interface |
RS-485Interface, two-wire system |
|
Communication Protocol |
YD/T1363Communication protocol/modbus protocol |
||
|
data format |
n81、e81、o81、n82 |
||
|
COMMUNICATION RATE |
Baud rate1200、2400、4800、960019200, can be set |
||
|
apparent show |
Electrical parameter inquiry |
U、I、P、Q、PFFrequency, total active power, total reactive power |
|
|
Equipment parameter query |
Address, baud rate, date and time, range, transformation ratio, voltage exceeding limit, frequency exceeding limit |
||
|
Version information |
Version information of the instrument |
||
|
Pulse indicator light |
1~4Active energy pulse and second pulse in the circuit |
||
|
Reverse indicator light |
1~4Reverse indication of circuit current |
||
|
Alarm indicator light |
Including power outage, oil engine power supply, voltage exceeding limit, frequency exceeding limit, lightning arrester failure, lightning arrester air disconnection, phase sequence error, and smart meter fault alarm indication |
||
|
Communication indicator |
RS485Communication transmission and reception instructions |
||
|
ring area |
work environment |
Working temperature:-25~60℃ |
|
|
storage environment |
Storage temperature:-40~85℃ |
||
|
relative humidity |
relative humidity≤95%No condensation |
||
|
peaceful complete |
pressure resistance |
Voltage signal andRS485>4kV |
|
|
isolation |
Output, input, and power supply to the casing>5M |
||
|
EMC Metrics |
Fast transient pulse |
voltages>4kV DC power supply>2kVAC power supply>4kV |
|
|
Lightning Protection |
voltages>4kV DC power supply>2kVAC power supply>4kV |
||
|
Electrostatic air discharge |
casing>15kV |
||
External dimensions