standard: The technical specifications of this product comply with IEC584-3 and GB4989-94 standards.
purpose:http://www.ktybdl .. net/info.asp? second_id=3029
Compensation wires, compensation cables, and thermocouples are used in temperature measurement and control systems in factories, mines, and scientific research departments such as instrumentation, power, metallurgy, petroleum, chemical, and textile industries. The testing cable is easy and simple to lay, with characteristics such as moisture resistance, fire resistance, acid and alkali resistance, high temperature resistance, and aging resistance. Shielding can prevent external interference.
Usage temperature: Ordinary GVV (RP) -20 ℃~+105 ℃ Temperature resistant FF46-GS (RP) -40 ℃~+200 ℃ Fire resistant and high temperature resistant HF4B -40 ℃~+380 ℃
Main Technical Data: 1. Compensation cables are divided into SC BC KC KX JX TX EA according to product varieties, where the letter "X" represents an extended compensation wire and the letter "C" represents a compensation cable. The difference between them is that the nominal chemical composition and thermoelectric potential of the alloy wire of the extended cable are the same as those of the matched thermocouple wire. The nominal chemical composition of the alloy wire used in compensating cables is different when paired with thermocouple wires, but the nominal value of the thermoelectric potential is the same as that of the thermocouple used when the temperature is between 0~100 ℃ or 0~200 ℃. The thermoelectric potential and resistance values comply with the specifications in the table below. 2. The insulation resistance of the compensating cable for moisture resistance test shall not be less than (10 meters) 25M Ω after 24 hours in 40 ℃ water 3. After 24 hours of heat aging resistance, the compensating cable undergoes a 5-fold outer diameter test and does not break down after a voltage test of 1000V/1min.
|
EX-GVVP 4 * 2 * 1.5E compensation cable price
|
4、 Main structural materials and codes http://www.ktybdl .. net/info.asp? second_id=3029
project |
code |
Meaning of code |
project |
code |
Meaning of code |
Flame retardant properties |
/ |
Non flame retardant |
Insulation material |
V |
Polyvinyl chloride |
ZC |
Ordinary flame retardant |
F |
FEP fluoroplastic |
ZL |
Low smoke, low halogen flame retardant |
VD |
Low smoke, low halogen flame retardant polyvinyl chloride |
ZW |
Low smoke halogen-free flame retardant |
sheathing material |
V |
Polyvinyl chloride |
Series code |
C |
Compensation cable |
VD |
Low smoke, low halogen flame retardant polyvinyl chloride |
Use classification |
G |
Generally used (100 ℃) |
B |
Alkali free glass fiber |
H |
Heat resistant grade (200 ℃) |
Shielding material |
/ |
No shielding |
accuracy class |
/ |
Ordinary level |
P |
Copper wire braided shielding |
S |
Precision |
P1 |
Tin plated copper wire braided shield |
thermal rating |
70 |
The maximum operating temperature is 70 ℃ |
P2 |
Copper tape or copper plastic composite tape wrapped shielding |
100 |
The maximum operating temperature is 100 ℃ |
P3 |
Aluminum tape or aluminum-plastic composite tape wrapped screen |
200 |
The maximum operating temperature is 200 ℃ |
armoring material |
22/23 |
Steel wire/fine steel wire armor |
260 |
The maximum operating temperature is 260 ℃ |
Material |
R |
Multi stranded conductor |
|
Compensation wire, compensation cable |
Equipped with thermocouple |
model |
Compensation alloy wire |
Insulation layer coloring |
Graduation |
name |
positive electrode |
negative electrode |
positive electrode |
negative electrode |
BC |
copper |
copper |
red |
yellow |
B |
Platinum rhodium 30- Platinum rhodium 6 |
SC |
copper |
copper-nickel |
red |
green |
S |
Platinum rhodium 10 platinum |
KC |
copper |
constantan |
red |
blue |
K |
Nickel chromium nickel silicon |
KX |
Nickel chromium |
Nickel silicon |
red |
black |
K |
Nickel chromium nickel silicon |
EX |
Nickel chromium |
copper-nickel |
red |
palm |
E |
Nickel chromium copper nickel |
JX |
iron |
copper-nickel |
red |
purple |
J |
Iron copper nickel |
TX |
copper |
copper-nickel |
red |
white |
T |
Copper Copper Nickel |
NX |
Nickel chromium silicon |
Nickel silicon |
red |
ash |
N |
Nickel chromium silicon nickel silicon |
NC |
iron |
copper-nickel |
red |
ash |
N |
Nickel chromium silicon nickel silicon |
|
1. Equipped with K-type thermocouple 2x1.5mm2 Compensation wire (shielding) |
Example: (1) Fire resistant and high temperature resistant type expression KX-HF4BP 2x1.5mm2 |
(2) Fire resistant and temperature resistant type expression EX-FF 2x2.5mm2 |
(3) Common Type Representation KC-GV2P 2x1.5mm2 |
2. Equipped with 4 pairs of E-type thermocouples 2x1.5mm<2 Compensation cable (shielded) |
Example: (1) Fire resistant and high temperature resistant type expression KX-HF4BP 4x2x1.5mm2 |
(2) Fire resistant and temperature resistant type expression EX-FPF 4x2x2.5mm2 |
(3) Ordinary expression EX-GVVP 4x2x1.5mm2 |
|
Compensation cable parameters |
Wire division number |
Wire core |
Equipped with thermocouple model |
positive electrode |
negative electrode |
new |
past |
material |
color |
material |
color |
IEC NEW(New) |
IEC NEW(Old) |
SC |
LB |
copper |
red |
copper-nickel |
green |
S(Platinum rhodium 10 platinum) |
LB-3 |
BC |
. |
copper |
red |
copper |
palm |
B(Platinum rhodium 30 Platinum rhodium 6) |
. |
KC |
EU |
Nickel chromium |
red |
constantan |
blue |
K(Nickel chromium nickel silicon) |
EU-2 |
KX |
EU |
Nickel chromium |
red |
Nickel silicon |
black |
K(Nickel chromium nickel silicon) |
EU-2 |
EX |
. |
Nickel chromium |
red |
copper-nickel |
palm |
E(Nickel chromium copper nickel) |
. |
JX |
. |
iron |
red |
copper-nickel |
purple |
J(Iron copper nickel) |
. |
TX |
. |
copper |
red |
copper-nickel |
white |
T(Copper Copper Nickel) |
. |
. |
EA |
Nickel chromium |
red |
Copper Exam |
yellow |
. |
EA-2 |
|
model |
100% |
200% |
Reciprocating resistor at 20 ℃ |
Thermoelectric potential (mv) |
Difference (mv) |
Thermoelectric potential (mv) |
Charge difference (mv) |
Ordinary (B) |
Precision grade (A) |
Ordinary (B) |
Precision grade (A) |
SC |
0.645 |
±0.037 (5℃) |
±0.023 (3℃) |
1.44 |
±0.057 (5℃) |
- |
0.1 |
BC |
0.033 |
. |
. |
0.178 |
. |
. |
- |
KC |
4.095 |
±0.105 |
0.063 |
6.137 |
±0.201 |
. |
- |
KX |
4.095 |
0.105 |
0.063 |
8.137 |
0.1 |
0.06 |
1.5 |
EX |
6.317 |
0.17 |
0.102 |
13.419 |
0.183 |
0.111 |
0.8 |
JX |
5.268 |
0.135 |
0.081 |
10.777 |
0.138 |
0.083 |
0.8 |
TX |
4.277 |
0.047 |
0.024 |
9.286 |
0.053 |
0.043 |
0.8 |
EA |
6.95 |
0.3 |
0.2 |
14.56 |
0.38 |
±0.300 |
- |
|
When placing an order, please indicate the model, specifications, wire core cross-section, number of wire cores, shielding method, and quantity Example: EX-GVVR 2 × 2.5mm2 1500m EX-FPF-GS 24 × 2 × 2.5mm2 1000m (total shielding) KX-HF4BPP-GS 12 × 2 × 1.5mm2 12000m (split screen) |
Compensation wires and cables for thermocouples |
Compensation wire manufacturing basis: GB/T 4989-94 Compensation cable manufacturing basis: Enterprise standard This product is mainly used as a connecting wire for automated measuring instruments in industries such as power, chemical, petroleum, metallurgy, textile, and national defense. |
|
PRODUCT MODEL |
Product Name |
Equipped with thermocouple |
Thermocouple division number |
SCAnd RC |
Copper Copper Nickel 0.6 Compensation Wire |
Platinum rhodium 10 platinum thermocouple Platinum-13% Rhodium/Platinum thermocouple |
SAnd R |
KCA KCB KX |
Copper Copper Nickel 22 Compensation Wire Copper Copper Nickel 40 Compensation Wire Nickel chromium 10 nickel silicon 3 extended compensating wire (cable) |
Nickel chromium nickel silicon thermocouple |
K |
NC NX |
Copper Copper Nickel 18 Compensation Wire Nickel chromium 14 silicon nickel silicon 4 extended compensating wire (cable) |
Nickel chromium silicon nickel silicon thermocouple |
N |
EX |
Nickel chromium 10 nickel silicon 45 extended compensating wire (cable) |
Nickel chromium copper nickel thermocouple |
E |
JX |
Iron Copper Nickel 45 Extended Compensation Wire (Cable) |
Iron/Copper-Nickel thermocouple |
J |
TX |
Copper Copper Nickel 45 Extended Compensation Wire (Cable) |
copper constantan thermocouple |
T |
|
Product classification, tolerance level, and labeling |
Classification of compensation wire (cable) usage |
sign |
Allowable deviation level and marking |
Common |
Precision grade |
Generally used |
G |
- |
S |
heat resistant |
H |
|
Main structural components of the product |
Nominal cross-sectional area mm2 |
Insulation and sheath materials |
Number of cores |
Shielding form |
Shielding material |
0.2-2.5 |
General product: PVC insulation PVC sheath Heat resistant product: PTFE wrapped insulation Alkali free glass fiber sheath |
Wire: 1 Cable 2-37 |
Regarding shielding Total shielding For blocking+total blocking |
Tin plated copper wire Galvanized steel wire Composite copper strip Composite aluminum strip |
|
operating characteristics *The allowable working temperature for compensating wires (cables) is generally -20oC -+100oC, while the allowable working temperature for heat-resistant compensating wires (cables) is -25oC -+200oC. *The ambient temperature during the laying of compensating wires (cables) should not be lower than 0oC, and the bending radius should not be less than 10 times the outer diameter of the wire (cable). |