Measurement range: 0.1 to 2.5mg/L (ppm) CH2N2O, 0.2 to 5mg/L (ppm) CH2N2O
Adopting unique SMD microcomputer control technology, high-quality narrow band filter, temperature compensated LED optical system, built-in reaction timer, ensuring the results between sample measurement and user *, compact overall design, waterproof sample pool, ensuring fast and accurate measurement, good reproducibility, with calibration function and built-in software adjustment function, applied in scientific research, metrology for sample detection and identification.
Performance Features Highlights
Equipped with unique SMD microcomputer control technology, high-performance narrowband filter and temperature compensated LED light source system, new waterproof design, exquisite portability, and background light display screen.
▷ Factory and user-defined dual calibration function, automatic memory of the last zero calibration, no need for frequent zero calibration, good GLP function, automatic shutdown setting.
Unique IRiM infrared data transmitter [recommended ET214050] design, 16 sets of data storage, can be accessed and read at any time, convenient for on-site data organization and recording, and easy to connect with a computer for data transmission.
Technical Specifications
ET8500 urea
measurement range
0.1 to 2.5mg/L(ppm)CH2N2O,0.2 to 5mg/L(ppm)CH2N2O
resolution
0.1 mg/L(ppm)
Accuracy @ 20 ° C
±0.2 mg/L(0.1 to 2.5 mg/L)、±0.4 mg/L(0.2 to 5 mg/l)
optical system
Waterproof sample pool, temperature compensated LED optical system;
Wavelength accuracy: ± 1 nm; Resolution: 0.01A, Accuracy: 3% F.S. @ 20 to 25 ° C
Method Standard
Urease/indigo colorimetric method
calibration mode
Automatic zero point calibration, factory calibration, and user-defined dual calibration modes
data management
16 sets of data storage, which can be accessed at any time; Cooperate with ET214050 IRiM infrared data transmitter for convenient data transmission with PC
Power mode
4 x 1.5AAA battery, automatically shuts down after 10 minutes without operation, LCD backlight
Applicable Environment
5 to 40 ° C, RH: 30 to 90% non condensing
Dimensions & Weight
Host size: 155 × 75 × 35mm, host weight: 260g
certification standard
CE certification, IP68 (under 0.1m conditions, 1 hour)
Recommend purchasing accessories
ET197620 custom glass colorimetric dish, specification: H48mm × ∅ 24mm, 12 sets/group
ET517800 customized specialized urea reagent, type: tablet+water solution
ET214050 customized dedicated IRiM infrared data transmitter, USB interface, suitable for data transmission to a computer for data, management, and analysis
ET197635 customized glass colorimetric dish cleaning cloth, packaging: 4 pieces/group
ET364107 Customized Tablet Special [Blue] Grinding Rod, Specification: 10cm