E+H split type ultrasonic level meter
Product Description: An integrated measurement transmitter for non-contact level measurement of liquids, slurries, and blocks. Advantages: Four line pure text display menu style on-site operation, quick and easy instrument debugging, with 6 optional languages for on-site envelope display, and simple instrument fault diagnosis. FieldCare operation software is provided, allowing users to easily remotely operate the instrument, diagnose faults, and compile measurement point files. Suitable for explosive hazardous areas (gas Ex, dust Ex) with up to 32 lines

Technical parameters of E+H split type ultrasonic level meter

Technical specifications for split type ultrasonic level gauge
Range:
LA-4 : 4m
LA-6 : 6m
LA-8 : 8m
LA-12: 12m
LA-15: 15m (liquid level), 7m (material level)
LA-20: 20m (liquid level), 10m (material level)
LA-30: 30m (liquid level), 15m (material level)
LA-40: 40m (liquid level), 25m (material level)
blind area:
LA-4 : 0.20m
LA-6 : 0.25m
LA-8 : 0.30m
LA-12 : 0.40m
LA-15: 0.60m
LA-20: 0.80m
LA-30: 1.20m
LA-40: 1.40m
Temperature range: -40 ℃ to+85 ℃
Pressure range: ± 0.1MPa
Beam angle: 8 ° (3db) 5 °/(over 12 meters)
Shell material: ABS/PVC
Shell protection level: IP68
Corrosion resistance: Strong corrosion resistance
Probe lead out cable length: 10m (standard)/15m or more with standard 15m cable
Installation method: threaded or flanged

E+H split type ultrasonic level meterapplication
The Prosonic FMU 90/95 ultrasonic transmitter is used in conjunction with the Prosonic FDU 91/91F/92/93/95/96 series sensors.
FMU90 is equipped with 1 or 2 ultrasonic probes, while FMU95 is equipped with 5 or 10 ultrasonic probes.
Maximum range of 70 meters
Can perform limit measurement (with up to 6 relays)
Multi stage pump control (interactive), barrier control
It can measure the flow rate of the medium in open channels and measuring weirs