The HI255 dual channel multifunctional acidity/ORP/conductivity/TDS/salinity analyzer allows you to simultaneously measure the pH, TDS, ORP, salinity,
Product details
Dual channel multifunctional acidity/ORP/conductivity/TDS/salinity analyzer HI255
Model number
pH255
Measurement project
Acidity and oxidation-reduction (ORP) technical indicators
measuring range
-2.00 to 16.00pH; -2.000 to 16.000pH; ORP: ±699.9mv; ±2000mv
Resolution
0.01pH 0.001PH 0.1mv (± 699.9mv) 1mv (± 2000mv)
measurement accuracy
± 0.01pH ± 0.002pH ± 0.2mv (± 699.9mv) ± 1mv (± 2000mv)
temperature compensation
Automatic or manual temperature compensation -10.0 to 120.0 ° C pH
Correction method
Automatically select point 1, 2, and 3 for calibration from five calibration points: pH4.01, pH6.86, pH7.01, pH9.86, and pH10.01
Supporting acidity
The electrode can be selected as HI1131, HI1200, or other composite electrodes for measurement purposes according to customer needs
Measurement project
Conductivity and TDS technical indicators
measuring range
EC:0.00 to 29.99μS/cm, 30.0 to 299.9μS/cm, 300 to 2999μS/cm, 3.00 to 29.99mS/cm, 30.0 to 200.0 mS/cm, up to 500 mS/cm (actual conductivity value without temperature compensation function)
TDS:0.00 to 14.99ppm(mg/L), 15.0 to 149.9 ppm(mg/L), 150 to 1499 ppm(mg/L), 1.50 to 14.99 ppt(g/L), 15.0 to 100.0 ppt(g/L), up to 400.0 ppt(g/L) ( Actual TDS value without temperature compensation function
Resolution
EC:0.01μS/cm, 0.1μS/cm, 1 uS/cm, 0.01 mS/cm, 0.1 mS/cm
TDS:0.01 ppm(mg/L), 0.1 ppm(mg/L), 1 ppm(mg/L), 0.01 ppt(g/L), 0.1 ppt(g/L)
measurement accuracy
EC:± 0.01% ± (0.05 μ S/cm or the larger of one word) of the reading
TDS:± 1% ± 0.03 ppm (mg/L) of the reading or the larger of one word)
Correction method
Automatically select one calibration point from six calibration points: 84.0, 1413 μ S/cm, 5.00, 12.88, 80.0, and 111.8mS/cm
temperature compensation
Temperature compensation coefficient within the range of 0 to 60.0 ℃: 0.00 to 6.00%/° C; factory set temperature compensation coefficient: 1.90%/℃
TDS conversion coefficient
Manual adjustment within the range of 0.40 to 0.80 (factory set coefficient: 0.50)
Supporting electrode
HI76310 high-performance four ring conductive electrode with a wide measurement range
Measurement project
Salinity (NaCl) technical indicators
measuring range
0.0 to 400.0% NaCl Resolution 0.1% NaCl
measurement accuracy
± 1% of the reading Correction method Single point automatic calibration (recommended to use HANNA calibration buffer HI7037L)
Measurement project
Temperature technical indicators
measuring range
Acidity temperature range: -10 to 120.0? C conductivity temperature range: 0.0 to 6.0? C
resolution
0.1? C measurement accuracy ±0.4 ? C Matching temperature probe HI7662 temperature probe
Measurement project
Other technical indicators
data interface
RS-232 data interface Data Storage 200 Group input impedance 1012Ohm
Usage environment
0 to 50? C 95%RH Supporting power supply 12VDC Power size/weight 240×182×74mm/1.1Kg