NAI-DCY-12GD, NAI-DCY-24GD current dry nitrogen blowing instrument specifications: 12 holes, 24 holes (manual, electric)
Note: Sample tube processing default diameter: 16mm (tubes larger than 16mm can be customized)
Product Description
The dry nitrogen blowing instrument NAI-DCY-12GD adopts blowing and trapping technology, and can also control the temperature and heat of the sample. It uses inert gases such as nitrogen to quickly, controllably, and continuously blow onto the surface of the sample to achieve rapid anaerobic concentration of the sample solution. Dry nitrogen blowing apparatus is mainly used for the concentration preparation of large quantities of samples, such as in the fields of pharmaceuticals, medical testing, pesticide residue detection, drug screening, hormone analysis, liquid phase, gas phase, and mass spectrometry analysis for sample preparation
Application Range
1. Pesticide analysis: vegetables, fruits, grains, plant tissues, etc
2. Pharmaceutical inspection: Traditional Chinese Medicine pharmaceuticals and drug testing
3. Environmental analysis: drinking water, groundwater, polluted water, etc
4. Bioanalysis: Serum, plasma, blood, urine
5. Product inspection: Inspection of dioxins, Croods, etc
6. Food and beverages: milk, alcohol, liquid beverages
Main characteristics: Principal character
1. Each blowing needle can be independently controlled to avoid cross contamination. The height of the instrument's air chamber can be adjusted by itself, and it is equipped with a standard air needle length of 15 centimeters.
2. NAI-DCY-12GD has 12 airway control switches to save gas, and the position of each blowing needle can be independently changed for blowing.
3. When concentrating toxic solvents, the entire system can be placed in a fume hood to reduce danger.
4. Built in over temperature protection device, automatic fault detection and alarm function, convenient to use.
5. LED display screen, temperature synchronous display, time decreasing display, can observe temperature changes in real time.
Technical parameters
1. Operating environment temperature: 5 ° C~30 ° C Relative humidity: ≤ 70%
2. Power supply: AC220V~50-60Hz
3. Temperature range: Room temperature+5 ° C~150 ° C
4. Timed time: 99 hours and 59 minutes in duration
5. Temperature control accuracy: ≤± 0.5 ° C
6. Display accuracy: ± 0.1 ° C
7. Temperature uniformity: 100 ° C ≤± 0.5 ° C
8. Temperature uniformity: 150 ° C ≤± 1 ° C
9. Heating time (40-150 ° C): ≤ 30 minutes
10. Maximum lifting stroke: 200mm Maximum gas flow rate: 15L/min
Model selection
PRODUCT MODEL | NAI-DCY-12GD | NAI-DCY-24GD |
Number of processed samples | 12 independent controls | 24 independent controls |
Number of modules | 1 piece | 2 of them |
Power | 200w | 400w |
fuse | 250V 3A Ф5×20 | 250V 4A Ф5×20 |
precision | ≤±0.5℃ | ≤±0.5℃ |
Maximum lifting stroke | 200mm | 200mm |
Dimensions (mm) | 280X240X500 | 280X240X500 |
Timed Time | 0~99h59min | 0~99h59min |
gas flow | Controllable 0-15L/min | Controllable 0-15L/min |
Maximum gas pressure | 0.02Mpa (using ≤ 16 air needles) | 0.05Mpa (using more than 16 air needles) |
Maximum gas pressure | 1000W | 1000W |
weight | 7KG | 7.5KG |
Test tube diameter | 16mmx45mm | 16mmx45mm |
Optional module
Type |
Test tube diameter |
Number of test tubes |
Number of test tubes |
MK01 |
10mm |
12 | 24 |
MK02 |
12mm |
12 |
24 |
MK03 |
13mm |
12 |
24 |
MK04 |
15mm |
12 |
24 |
MK05 |
16mm |
12 |
24 |
MK06 |
19mm |
12 |
24 |
MK07 |
20mm |
12 |
24 |
MK08 |
26mm |
12 |
24 |
MK09 |
1500mm |
12 |
24 |
MK10 |
2000mm |
12 |
24 |
NAI Dry Nitrogen Blower | Dry Nitrogen Blower Quotation | Dry Bath Nitrogen Blower | Dry Heat Nitrogen Blower Quotation | Dry Nitrogen Blower Quotation