Drucker DPI 612Flex series integrated interchangeable range pressure calibrator
Pressure quick couplings and connecting pipes reduce on-site leakage
Product details

Drucker DPI 612Flex series integrated interchangeable range pressure calibrator

DPI612

A sturdy pneumatic/hydraulic integrated pressure calibrator that can quickly switch pressure ranges by replacing pressure modules. It can also measure process signals and provide circuit power. Building on the various advantages of the DPI 610/615 series pressure calibrator, it has stronger pressure generation capabilities, higher accuracy, and a simpler touch operation interface.

characteristic
• Integrated pressure calibration system: pressure source signal measurement and recording function, error analysis function
• Optimal portable pressure calibration accuracy
• Rapid pressurization - Vacuum to 100MPa
• Simple and easy-to-use touch screen operation

Pressure quick couplings and connecting pipes reduce on-site leakage

Reliable and efficient pressure building capability

Three models cover a pressure range from vacuum to 100MPa

Generate a gas pressure of 2MPa in 30 seconds

With a high-pressure capacity of 10 MPa, gas cylinders and pressure regulating valves are no longer required on site

100 MPa liquid pressure building capacity

Flexible range switching - simply replace the pressure module, the host does not require any settings or changes

Variable program can meet different applications and reduce downtime

31 interchangeable pressure modules with a minimum range of 2.5kPa and a maximum range of 100MPa

Accuracy up to 0.005% FS

Hot swappable ", plug and play, no additional tools or seals required

The pressure module of DPI 612 Flex series can be freely interchanged and can work on any host. In addition, it can also be compatible with the pressure module of our other model DPI 620 Genii multifunctional calibrator

Electrical signal function

High accuracy matching with pressure

The DPI 612 Flex series retains various electrical measurement and output functions of the DPI 610 series, greatly improving measurement accuracy and simplifying electrical connection methods

The accuracy of electrical signal measurement for DPI 612 Flex includes one-year stability, temperature influence, and uncertainty of calibration standards, making its accuracy index about three times higher than that of DPI 610 series

Simplified the wiring method for electrical measurement, with four 4mm electrical sockets

general indicators
display Size: 4.3-inch bottle 480 × 272 pixels Color LCD touch operation screen
Memory 8Gb (standard configuration), used to store calibration processes, calibration data, and other stored data
language Chinese operation menu
Pressure Unit 25 pressure units to choose from (some regions may set a reduced selection of pressure units)
The data on the factory calibration certificate will be represented in three pressure units, which are based on bar, PSI and Pa
Environmental temperature for use -10~50 ℃, when powered by the external power adapter IO620-PSU, it is 0~40 ℃. For the hydraulic host DPI 612 hFlexPro, when using water as the medium, the temperature range is 4~50 ℃
storage temperature -20 ℃~70 ℃, when there is water inside the hydraulic host DPI 612 hFlexPro, it is 4~70 ℃
protection grade IP 54, Dust and water splash prevention in all directions
Environmental humidity for use 0~90% RH, non condensing, compliant with Def Stan 66-31, 8.6 cat III
Shock/vibration BS EN 61010-1:2010/MIL-PRF-28800F CLASS 2. Passed 1-meter drop test
Use altitude range Below 2000m
EMC BS EN 61326-1:2013
Electrical safety BS EN 61010-1:2010
Pressure safety Guidelines for Pressure Equipment - Class: Sound Engineering Practice (SEP)
Housing material High performance materials such as rubber and acrylic
authentication CE marking
power supply Standard lithium battery power supply (order number: CC3800GE); Capacity: 3800 mAh 14.1Wh. Normal voltage: 3.7 V. Charging environment temperature: 0~40 ℃, discharging
Temperature: -20 degrees Celsius~ 60 ℃, charge/discharge cycle:>500 times>70% capacity
Power adapter/charger (GE order number: IO620-PSU is standard and can also be powered by 8 No. 5 batteries
Battery operating time When powered by a lithium battery, it takes 12-26 hours, depending on the function being used
When powered by dry batteries, it also takes 12-26 hours, depending on the function being used
interface USB type A, USB type mini B

For more information, please contact us

ordering information

Please provide the complete model according to the information in the technical specification sheet. For example, ordering
If you purchase a standard DPI 620 pFlexPro 2MPa kit, the model number is DPI 612, PFP, 20G, This ordering information indicates that it is a kit and will include various accessories marked in the DPI 612 pFlexPro technical specification sheet. If the pressure range ordered is not in the technical specification sheet, such as ordering a 35kPa range, the model is DPI 612, PFX, 00, and then we need to separately order the PM 620 pressure module, 35kPa range. This model only includes rechargeable battery components and no other accessories.
attachment

Note - The attachments marked with an asterisk (*) are the standard attachments included in the kit when ordering. Please refer to the technical specification sheet.
*Portable bag (P/N IO620-CASE-3) soft portable protective bag, equipped with shoulder straps and large capacity
Accessory pocket, can carry various accessories.

Backup rechargeable battery pack (P/N IORBAT-7W)

Backup lithium battery, suitable for DPI 611 and DPI612 series hosts

Backup power adapter (P/N IO620-PSU)

A power adapter, also known as a charger, equipped with various power sockets and plugs, with an input voltage of 100-240V, 50/60Hz.
Battery Charging Stand (P/N IOBAT-7-DC)
The external battery charging dock and universal charging head can charge the backup battery, and it takes about 6 and a half hours to fully charge it at once.

USB cable (P/N IO620-USB-PC)

Used for connecting computers to DPI 612.

IDOS to USB Converter (P/N IO620-IDOS-USB)

Used to connect the external IDOS pressure module to the DPI 612 host. When using this attachment, a USB cable (P/NIO620-USB-PC) is also required.
USB to RS 232 cable (P/N IO620-USB-RS232)

Provide RS 232 interface for DPI 612. 920-651A
*Moisture and dirt isolator
Used to isolate various moisture/contaminants from entering DPI612 and avoid phase interference between pneumatic systems
Mutual pollution. One end can be directly connected to the quick connector of DPI612, and the other end has the same interface as the DPI 611 quick pressure output port. Only applicable to pneumatic models, not applicable to hydraulic DPI 612 hFlex models.
*P/N IO620-IDT621: Maximum working pressure 2MPa
*P/N IO620-IDT622: Maximum working pressure 10 MPa
Pressure quick couplings and connecting pipes
The following connecting pipes and pressure fittings are both compatible with DPI 612Flex, DPI 611 and DPI 620 series pressure bases.
*IOHOSE-NP1: 1-meter pneumatic connecting pipe, maximum pressure 4MPa
*IOHOSE-NP2: 2-meter pneumatic connecting pipe, maximum pressure 4MPa
*P/N IO620-HOSE-P1: 1-meter pneumatic connecting pipe, maximum pressure 40MPa
P/N IO620-HOSE-P2: 2-meter pressure connecting pipe, maximum pressure 40MPa
*P/N IO620-HOSE-H1:1 meter hydraulic pipe, maximum pressure 100MPa
P/N IO620-HOSE-H2: 2-meter hydraulic pipe, maximum pressure 100MPa
P/N IO620-BSP: G-thread connector kit, G1/8 external thread, G1/4 external thread, G1/4 internal thread, G3/8 internal thread and G1/2 internal thread
P/N IO620-NPT: NPT pressure fitting kit 1/8 "external thread 1/4" external thread, 1/4 "internal thread, 3/8" internal thread, and 1/2 "internal thread
P/N IO620-MET: M14 * 1.5 internal thread and M20 * 1.5 internal thread joints
P/N IO620-COMP comparative test pump joint

To improve calibration efficiency, it is possible to compare and test pump options
Two inspected meters can be connected together, and one end of this option can be directly connected
On DPI611, the other end provides two pressure output ports.

pressure relief valve

Used to protect the PM 620 pressure module and the tested meter from overpressure.