Double 85 alternating humidity and heat test chamber
The Double 85 Alternating Low Temperature Alternating Damp Heat Test Chamber is mainly used to test the operating conditions of products in extremely
Product details

Mechanical structure:

1. The box is formed by a CNC digital working machine, with a beautiful and elegant circular arc shape, and a flat non reactive handle for easy operation.
2. The interior of the box is made of SUS # 304 high and low temperature resistant stainless steel plate. The exterior is made of SEEC high and low temperature resistant steel plate with powder baking paint to increase the appearance texture and cleanliness.
3. The supplementary water tank is placed at the lower part of the front side of the control box, and the design of the external pull type water tank makes it more convenient for the operator to supplement the water source. And it can be equipped with an automatic water replenishment system, with a water filtration device attached, without the need for manual replenishment, to facilitate the operator to replenish the water source.
4. Large scale observation and inspection with lighting to keep the box bright, and using embedded glass in the heating body to maintain a clear observation window at all times.
5. The box is made of high-strength PU foam and high-density glass fiber cotton, with a thickness of 10cm, which can avoid unnecessary energy loss.
6. There are two 50mm diameter test holes on the left and upper sides of the box, which can be used for external testing power or signal lines.
Programmable controller:
1. The controller adopts the American WINCON, Japanese UNIQUE, OYO touch screen series of true color LCD microcomputer controllers, which are beautiful and attractive.
2. The product adopts a resistive high-precision touch screen operation method, which allows users to directly click on the screen with a USB mouse or stylus to select functions or set parameters.
3. The programmable function has a capacity of 160Patten x 1600 steps x 999 cycles.
4. Screen display function: LCD display screen can display the test conditions (including temperature range, cycle times, running time, and remaining time, etc.).
5. It has program control and constant value control functions, which facilitate the use of various production conditions.
6. The setting of temperature slope allows for free control of operating time and heating rate.
7. The reservation activation function will automatically run when the system time reaches the set time, allowing for flexible control of the operation time and working conditions of the aging room.
8. Power off restart function, which can be operated by selecting cold start/hot start/interrupt.
9. The temperature control adopts P.I.D.+S.S.R. system synchronous coordinated control, which can improve the stability and service life of control components and interfaces.
10. Real time curve and historical curve query, convenient for users to observe temperature changes in real time.
11. Historical dump function. It has two USB interfaces, making it convenient for users to save historical data.
12. File backup function.
13. External computer connection interface, which can be connected to a computer for remote operation. It has the function of saving and printing curves and experimental data.
14. Run the cumulative function to facilitate customers to view the product usage status for corresponding maintenance and upkeep.
15. Screen saver function, better extending the service life of LCD screen.
16. When the system has a malfunction, it can display fault information, fault causes, and solutions.
17. It has the function of setting permission levels to avoid user misoperation.
18. The function of switching between Chinese and English is convenient for users of different languages to operate.
19. Control mode: PID (proportional integral derivative) automatic calculation, PID control is simple and easy to understand, and does not require precise system models or other prerequisites for use.
20. In the setting, if an error occurs, a warning signal will be provided.
21. The on/off function (which can be controlled by the controller to illuminate the test box) can save costs for designers and increase convenience of use.
22. Temperature sensor: PT-100 sensor; Or Swiss Rozhnick temperature and humidity integrated sensor
High temperature refrigeration and dehumidification system:
1. French imported Taikang high-efficiency, low-noise, and energy-saving refrigeration compressor.
2. Adopt condensation dehumidification method for dehumidification.
3. The entire system uses R134a environmentally friendly refrigerant.
4. Internal spiral K-TYPE refrigerant copper tube.
5. The entire system pipeline undergoes a 24-hour leak detection test with nitrogen pressurization, eliminating the possibility of refrigerant leakage in the system.
6. Air cooled condenser.
7. Slope type FIN-TUBE evaporator.
8. Original imported frozen components.
9. The main components of the system include: compressor, plate heat exchanger, evaporator, refrigerant, expansion valve, drying filter, solenoid valve, etc.
Low temperature refrigeration system:
1. Compressor:
a、 European original imported French (Taikang) Iron Armored Warrior high-efficiency, low-noise, energy-saving fully enclosed refrigeration compressor.
b、 The refrigeration system adopts a combination of binary cascade refrigeration and room temperature refrigeration design. Binary cascade refrigeration uses different compressors to work in different temperature ranges to increase the service life of the equipment.
2. The entire system uses R404a and R23 environmentally friendly refrigerants.
3. Internal spiral K-TYPE refrigerant copper tube.
4. The entire system pipeline undergoes a 24-hour leak detection test with nitrogen pressurization, eliminating the possibility of refrigerant leakage in the system.
5. Wave shaped finned forced air condenser.
6. Slope type FIN-TUBE evaporator.
7. Original imported solenoid valve, dry filter, Japanese Kawamura capillary tube and other refrigeration components.
8. The heating and cooling systems are completely independent, and all freezing system action programs are completely controlled by a microcomputer controller, achieving the advantages of maximum efficiency and power saving.
9. The main components of the system include: compressor, plate heat exchanger, evaporator, refrigerant, expansion valve, drying filter, solenoid valve, etc.
Wind system:
1. The air circulation adopts a side blowing and downward return design, with wind speed and pressure meeting the test standards, and the temperature stabilization time is fast at the moment of opening and closing the door.
2. By utilizing high-quality centrifugal fans for powerful air circulation, any dead corners can be avoided, resulting in even temperature distribution within the testing area.
3. The heating, cooling, humidification, and dehumidification systems are completely independent, which can improve efficiency, reduce testing costs, increase lifespan, and reduce failure rates.
4. More energy-efficient, in line with current international and domestic environmental requirements.
5. More silent, better ensuring a good office environment and working environment for operators.
6. Easy installation, maintenance, and repair.
7. High quality and reasonable design.
8. All components have extremely high reliability.
9. The main components of the system include: air duct, heating tube, evaporator, fan, motor, air guide fins, etc.