Disposable medical mask ethylene oxide chromatograph analysis equipment
Disposable medical mask ethylene oxide chromatograph analysis equipment. To fully demonstrate the current needs and assist medical device manufacturer
Product details

Today's celebrity product recommendations

Recommended product with high recommendation index: Gas chromatograph GC-6890 detection type equipment

Disposable medical mask ethylene oxide chromatograph analysis equipmentTo fully demonstrate the current needs and assist medical device manufacturers in quickly analyzing residual amounts of ethylene oxide, reforming technology, and utilizing new technologies to quickly and effectively analyze solvent residues in the production process.

Disposable medical mask ethylene oxide chromatograph analysis equipmentIncorporating current popular elements, user-friendly human-machine interface, and easy to learn. The integration of high-tech content makes the laboratory results close to reality.

Technical characteristics of equipment

⇒ Adopting a large LCD screen Chinese display mode, data display and processing are clear and visible.

⇒ It has self diagnostic function, over temperature power-off protection, and can store, call, and perform fifth order program temperature rise. It also has single column compensation to ensure the stability of the baseline during program temperature rise analysis;

⇒ Equipped with six independent temperature control zones and an intelligent rear door opening system, the cooling speed is very fast; Each gasification chamber, detector, and amplifier adopts modular design, making installation and replacement very convenient;

⇒ Equipped with a separate and complete capillary analysis system, an independent capillary splitter injector (including diaphragm cleaning, splitting, and tail blowing adjustment). Optional capillary splitter/non splitter injector;

Equipment technical specifications

The FID hydrogen flame ionization detector is used to detect ethylene oxide

Technical description of the detector

Hydrogen Flame Detector (FID):

Sensitivity Mt ≤ 1 × 10-11g/s (n-hexadecane)

Noise ≤ 5 × 10-14A linear range ≥ 106

Product instructions

As for the analysis of ethylene oxide, using only a gas chromatograph is not enough. We need to configure the necessary equipment for use, such as the corresponding gas source,HF-300 High Purity Hydrogen GeneratorGA-2009 oil-free and waterless air generatorAdd high-purity nitrogen gas. Another thing is that if we want to save manpower and resources, we can useHeadspace samplerHelp us analyze efficiently.