SR308Series diffusion silicon pressure transmitter
summary:
SRThe 308 series diffusion silicon pressure transmitter selects imported high-performance isolated diffusion silicon sensors and adopts advanced manufacturing processes internationally. It has the same robustness and reliability as similar imported transmitters and is suitable for pressure detection of corrosive media in various industrial fields.
SR308 is widely used in various industrial sites such as power, metallurgy, petroleum, chemical, building materials, papermaking, food, pharmaceuticals, heat treatment, and water treatment. And can be combined withSROther series of instruments are used in conjunction to achieve high-speed and stable automation control.
Main technical parameters:
Power supply: 24VDC output 4-20mA two-wire system
Zero position adjustable range: ± 5% F.S
Range adjustment ratio: above 3:1
Range: -100KPa to 0-60MPa
Load characteristics: The load maintains a constant current output within 0-600 Ω (24VDC power supply)
Explosion proof type d II BT4, intrinsically safe type ia II CT5
Overpressure limit: 2 times or more than the limit pressure
Temperature range: Process: -20~60 ℃
Accuracy level: ± 0.5%
Stability: ± 0.2% F.S
characteristic:
High cost performance ratio
Direct installation process
Good temperature characteristics
High comprehensive accuracy
SR308Selection table for series diffusion silicon pressure transmitters:
code | name | |||||||
SR308 | Diffuse silicon pressure transmitter | |||||||
code | DesIgn Serial Number | |||||||
A1 | Diffused silicon sensor | |||||||
B1 | Ceramic sensor | |||||||
code | pressure type | |||||||
A | absolute pressure | |||||||
G | gauge pressure | |||||||
S | Sealed gauge pressure | |||||||
code | local display | |||||||
1 | not have | |||||||
2 | 0-100% equally divided scale | |||||||
3 | 3 1/2 digit LCD | |||||||
4 | 3 1/2 digit LED | |||||||
code | measuring range | |||||||
1 | 0-35Kpa | |||||||
2 | 0-100Kpa | |||||||
3 | 0-200Kpa | |||||||
4 | 0-350KPa | |||||||
5 | 0-700Ka | |||||||
6 | 0-2.0Mpa | |||||||
7 | 0-3.5Mpa | |||||||
8 | 0-7MPap | |||||||
9 | 0-20Mpa | |||||||
0 | 0-60MPa | |||||||
code | accuracy | |||||||
A | 0.1%F.S | |||||||
B | 0.25%F.S | |||||||
C | 0.5%F.S | |||||||
code | Installation interface | |||||||
1 | M20×1.5 | |||||||
2 | 1/2NPT | |||||||
code | Explosion proof method | |||||||
N | Ordinary non explosion proof | |||||||
I | Intrinsic safety explosion-proof | |||||||
E | Isolation and Explosion proof |