VIP member
DPO3014 digital fluorescence oscilloscope
Features: Bandwidth of 100MHz, 300MHz, and 500MHz, with 2 or 4 channels and 16 digital channels (MSO series) on all channels
Product details
characteristic:
Bandwidth of 100MHz, 300MHz, and 500MHz
2 or 4 channels
16 digital channels (MSO series)
Sampling rate of 2.5GS/s on all channels
Record length of 5M points for all channels
>Maximum waveform capture rate of 50000 wfm/s
Complete set of advanced triggers
Performance characteristics
Vertical system simulation channel | |||||
Vertical system | MSO3012 DPO3012 |
MSO3014 DPO3014 |
MSO3032 DPO3032 |
MSO3034 DPO3034 |
MSO3054 DPO3054 |
Input Channel Mathematics | 2 | 4 | 2 | 4 | 4 |
Simulated bandwidth (-3dB) | 100MHz | 100MHz | 300MHz | 300MHz | 500MHz |
Calculated rise time 5mV/div (typical value) |
3.5ns | 3.5ns | 1.17ns | 1.17ns | 700ps |
Hardware bandwidth limit | 20MHz | 20MHz~150MHz | |||
Input Coupling | AC, DC, GND | ||||
Input impedance | 1 MΩ ± 1%, 75Ω ± 1%, 50Ω ±1% | ||||
Input sensitivity range, 1 M Ω | 1 mV/div - 10 V/div | ||||
Input sensitivity range, 75 Ω, 50 Ω | 1 mV/div - 1 V/div | ||||
Vertical Resolution | 8 bits (11 bits when using Hi Res) | ||||
Maximum input voltage, 1 M Ω | 300 VRMS, Peak value ≤ ± 450 V | ||||
Maximum input voltage, 75 Ω, 50 Ω | 5 VRMS, Peak value ≤ ± 20 V | ||||
DC gain accuracy | Set ± 1.5% for 5mV/div and above Set 2 mV/div to ± 2.0% Set 1 mV/div to ± 2.5% |
||||
Channel to channel isolation (Any two channels with equal vertical scales) |
≥ 100:1 when ≤ 100 MHz, ≥ 30:1 when>100 MHz to rated bandwidth |
Horizontal system simulation channel | |
characteristic | All MSO3000 models All DPO3000 models |
Maximum sampling rate (all channels) | 2.5 GS/s |
Maximum record length (all channels) | 5 M points |
The maximum duration captured at the highest sampling rate (for all channels) | 2 ms |
Time base range (S/div) | 1 ns - 1000 s |
Time base delay time range | -10 grids to 5000 seconds |
Channel to channel offset correction range | ± 100 ns |
Time base accuracy | ± 10 ppm at 1 ms intervals |
Horizontal system digital channel | |
characteristic | All MSO3000 models |
Maximum Sample Rate (Main time base, all channels) |
500 MS/s (2 ns resolution) |
Maximum record length (Main time base, all channels) |
5 M points |
Maximum Sample Rate (MagniVu, all channels) |
8.25 GS/s (121.2 ps resolution) |
Maximum record length (MagniVu, all channels) |
10k points, centered around the trigger point |
Minimum detectable pulse width | 2.0 ns |
Channel to channel offset | Typical value of 500 ps |
Bias range | ||
range | 1MΩ | 50Ω,75Ω |
1 mV/div - 99.5 mV/div | ±1 V | ±1 V |
100 mV/div - 995 mV/div | ±10 V | ±5 V |
1 V/div | ±100 V | ±5 V |
1.01 V/div - 10 V/div | ±100 V | NA |
Vertical System Digital Channel | ||
characteristic | All MSO3000 models | |
Number of input channels | 16 digital channels (D15 to D0) | |
threshold | Each set of 8 channels has a separate threshold set | |
Threshold selection | TTL, CMOS, ECL, PECL, User defined | |
User defined threshold range | -15 V to+25 V | |
Maximum input voltage | -20 V to+30 V | |
Threshold accuracy | ± (100 mV+3% threshold setting) | |
Maximum voltage swing | 500 mVpk-pk | |
Input impedance | 101 kΩ | |
Probe load | 8 pF | |
Vertical Resolution | 1 person |
TRIGGER | |
characteristic | describe |
Main triggering mode | Automatic trigger, normal trigger, and single trigger |
Trigger coupling | DC, AC, HF suppression (attenuation>50 kHz), LF suppression (attenuation<50 kHz), noise suppression (reduced sensitivity) |
Trigger release range | 20 ns - 8 s |
Trigger sensitivity | |
Internal DC coupling | 0.5 div at DC-50 MHz, increased to 1 div at rated bandwidth |
External (auxiliary input) | 200 mV at DC -50 MHz, increased to 500 mV at 250 MHz |
Trigger level range | |
characteristic | describe |
Any channel | ± 8 grids from the center of the screen |
External (auxiliary input) | ± 8 V |
MODE | |
mode | describe |
edge | Positive or negative slope on any channel or front panel auxiliary input. Coupling includes DC, AC, high-frequency suppression, low-frequency suppression, and noise suppression |
Sequence (triggered by B) | Trigger on time delay of -8 ns to 8 s, or trigger on event delay of -1 to 9999999 events |
Pulse width | Triggered on positive or negative pulse widths of>,<,=, or ≠ specific time periods |
Short pulse | Triggered when a pulse crosses a threshold but fails to cross the second threshold before crossing the first threshold again |
logic | When any logical code pattern in the channel becomes false or on a specified clock edge. When the code time type specified by the four input channels (A remains true) triggers acquisition. Any input can be used as a clock, with ND, OR, NAND, NOR defined as high, low, or indifferent |
Establishment time/ HOLD |
Triggered when the establishment time and holding time between the clock and data present in any two input channels exceed the threshold |
Rise/fall time | Trigger acquisition when the pulse edge rate is faster or slower than the specified value. The slope can be positive, negative, or any other value |
video | NTSC, PAL, and SECAM video signals trigger on all lines, odd, even, or all fields |
Extended video (optional) | Trigger 480 p/60, 576p/50, 720p/30, 720p/50,720p/60,875i/60, 1080i/50, 1080i/60, 1080p/24, 1080p/24sF,1080p/25,1080p/30, 1080p/50, 1080p/60 Customize dual level and three-level synchronous video standards |
I2C (optional) | On the I2C bus with a speed of up to 10 Mb/s, start, stop, ACK loss, address (7 or 10 bits), data or address and data trigger collection |
SPI (optional) | Trigger acquisition on SS, MOSI, MISO or MOSI and MISO on SPI bus up to 10.0 Mb/s (applicable only to 4-channel models). |
CAN (optional) | On CAN signals up to 1 Mb/s, the frame start, frame type (data, remote, error, overload), identifier (standard or extended), data, identifier and data, frame tail or ACK loss trigger collection. Further data can be specified to trigger collection when ≤,<,=,>, ≥ or ≠ specific data values. The sample points that users can adjust are set to 50% by default. |
I2S/LJ/RJ/TDM (optional) | Trigger Word Select, Frame Sync, or Data. You can specify data in one step, triggering collection when<,=,>, ≥, ≠ a certain data value or when it falls within or outside the range. The maximum data rate of I2S/LJ/RJ is 12.5 Mb/s. The maximum data rate for TDM is 25 Mb/s |
RS-232/422/485/UART (optional) | Trigger up to 10 Mb/s Tx start bit, Rx start bit, Tx packet tail 、 Rx packet tail, Tx data, Rx data, Tx parity error, and Rx parity error |
LIN (optional) | Triggering synchronization, identifiers, data, identifiers and data, wake-up frames, sleep frames, and errors (such as synchronization errors, parity errors, or checksum errors) up to 1 Mb/s (defined as 20 kb/s according to LIN) |
Parallel (only available on MSO models) | Trigger parallel bus data values. The parallel bus length can range from 1 bit to 16 bits. Supports binary and hexadecimal cardinality |
Acquisition mode | |
sampling | Collect sampling values |
Peak detection | Capture the narrowest 2 ns burr at all scanning speeds |
average | On average, it can include 2-512 waveforms |
envelope | The minimum maximum envelope reflects the peak detection data collected multiple times |
Hi-Res | Real time rectangular wave series averaging reduces random noise and improves resolution |
Scroll Mode | Scroll the waveform from right to left on the screen at a scanning speed of 40 ms/div or less |
Waveform measurement | |
cursor | Waveform and Screen |
automatic measurement | 229 types, of which up to 4 measurement functions can be displayed on the screen at once. Measurement includes cycle, frequency, delay, rise time, fall time, positive duty cycle, negative duty cycle, positive pulse width, negative pulse width, burst width, phase, positive overshoot, negative overshoot, peak to peak value, amplitude, high value m low value, maximum value, minimum value, average value, cycle mean, RMS, cycle RMS, area, and cycle area |
Measurement statistics | Mean, minimum, maximum, standard deviation |
Reference level | User definable automatic measurement reference levels can be specified in percentages or units |
gate | Use a screen or waveform cursor to isolate specific situations that occur within the collection to be measured. Measure using the entire record by default |
Power measurement (optional) | |
power quality measure |
VRMS, V Crest Factor, Frequency, I RMS, ICrest Factor, real power, apparent power, reactive power, power factor, phase angle |
Measurement of switch losses | Power loss: Ton, Toff, conducted power loss, total power loss, energy loss: Ton, Toff, conducted energy loss, total energy loss |
harmonic | THD-F, THD-R, RMS measurement, harmonic graph and table display, according to IEC61000-3-2 Class A and MIL-STD-1399, standard testing |
Ripple measurement | Vripple and Iripple |
modulation analysis | Graphic display+Pulse Width, - Pulse Width, Period, Frequency,+Duty Cycle, and - Duty Cycle modulation types |
Safe Operation Area | Graphic display and template testing for measuring the safe working area of switchgear |
DV/dt and dI/dt measurements | Conversion rate cursor measurement |
Waveform mathematical operation | |
algebraic operation | Waveform addition, subtraction, multiplication, division |
Mathematical functions | Integral, Differential, FFT |
FFT | Spectral amplitude. Set the FFT vertical scale to linear RMS or dBV RMS, and set the FFT window to rectangular, Hamming, Hanning, or Blackman Harris |
Advanced Mathematical Operations | Define comprehensive algebraic expressions, including waveforms, reference waveforms, mathematical functions (FFT, Intg, Diff, Log, Exp, Sqrt, Sine, Cosine, Tangent), scalars, up to two user adjustable variables and parameter measurement results (Period, Freq, Delay, Rise, Fall, PosWidth, NegWidth, BurstWidth, Phase, PosDutyCycle, NegDutyCycle, PosOversoot, NegOversoot, PeakPeak, Amplitude, RMS, CycleRMS, High, Low, Max, Min, Mean, CycleMean, Area, CycleArea, and trend charts), such as (Intg (Ch1- Mean (Ch1)) x 1.414 x VAR1) |
software | |
NI LabVIEWSignalExpressTMTektronix Edition | A comprehensive interactive measurement software environment optimized for the MSO/DPO3000 series, which can use an intuitive drag and drop user interface to instantly collect, generate, analyze, compare, import, and save measurement data and signals without requiring any programming. The software provides standard DPO3000 series support for collecting, controlling, viewing, and exporting real-time signal data. The full version can be tried for free for 30 days, providing additional features such as signal processing, advanced analysis, mixed signals, scanning, extreme testing, and user-defined steps. Order SIGEXPTE to receive permanent full version functionality |
OpenChoiceDesktop | Quickly and easily communicate between Windows PC and DPO3000 series via USB or LAN. Transfer and save settings, waveforms, measurements, and screen images |
IVI Driver | Provide standard instrument programming interfaces for commonly used applications, such as LabVIEW, LabWindows/CVI, Microsoft. NET, and MATLAB |
eScope | Control MSO/DPO3000 through a standard web browser and network connection. Just enter the IP address or network name of the oscilloscope, and a webpage will be displayed in the browser |
Display Features | |
display type | 9-inch (228.6 mm) LCD TFT color display |
Display resolution | 800 horizontal x 480 vertical pixels (WVGA) |
Waveform display style | Vector, dot, variable afterglow, infinite afterglow |
ruling | All, grids, markings, boxes, IRE, and mV |
format | YT and XY |
Waveform capture rate | >50,000 wfm/s |
Input/output ports | |
USB 2.0 High speed host port |
Supports USB massive storage devices and printers. One on the back panel and one on the front panel |
USB 2.0 High speed equipment port |
The rear panel connector can be used to control the oscilloscope using USBTMC, GPIB, and TEK-USB-488, or directly printed onto a compatible PictBridge printer |
LAN port | RJ-45 connector, supports 10/100Base-T |
Video Output Port | DB-15 female connector, connected to an external monitor or projector to display oscilloscope images |
auxiliary input | Front panel BNC connector. Input impedance of 1 megaohm. Maximum input 300 V RMS, peak value ≤± 450 V |
Probe compensator output |
not have |
Online inquiry