Xi'an Antai Testing Equipment Co., Ltd
Home>Products>DPO3012 digital fluorescence oscilloscope
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    Zhicheng Business C207, No.17 Gaoxin Fourth Road, High tech Zone, Xi'an City
Contact Now
DPO3012 digital fluorescence oscilloscope
Features: Bandwidth of 100MHz, 300MHz, and 500MHz, with 2 or 4 channels and 16 digital channels (MSO series) on all channels
Product details

characteristic:
Bandwidth of 100MHz, 300MHz, and 500MHz
2 or 4 channels
16 digital channels (MSO series)
Sampling rate of 2.5GS/s on all channels
Record length of 5M points for all channels
>Maximum waveform capture rate of 50000 wfm/s
Complete set of advanced triggers
Performance characteristics

Vertical system simulation channel
Vertical system MSO3012
DPO3012
MSO3014
DPO3014
MSO3032
DPO3032
MSO3034
DPO3034
MSO3054
DPO3054
Input Channel Mathematics 2 4 2 4 4
Simulated bandwidth (-3dB) 100MHz 100MHz 300MHz 300MHz 500MHz
Calculated rise time
5mV/div (typical value)
3.5ns 3.5ns 1.17ns 1.17ns 700ps
Hardware bandwidth limit 20MHz 20MHz~150MHz
Input Coupling AC, DC, GND
Input impedance 1 MΩ ± 1%, 75Ω ± 1%, 50Ω ±1%
Input sensitivity range, 1 M Ω 1 mV/div - 10 V/div
Input sensitivity range, 75 Ω, 50 Ω 1 mV/div - 1 V/div
Vertical Resolution 8 bits (11 bits when using Hi Res)
Maximum input voltage, 1 M Ω 300 VRMS, Peak value ≤ ± 450 V
Maximum input voltage, 75 Ω, 50 Ω 5 VRMS, Peak value ≤ ± 20 V
DC gain accuracy Set ± 1.5% for 5mV/div and above
Set 2 mV/div to ± 2.0%
Set 1 mV/div to ± 2.5%
Channel to channel isolation
(Any two channels with equal vertical scales)
≥ 100:1 when ≤ 100 MHz, ≥ 30:1 when>100 MHz to rated bandwidth
Horizontal system simulation channel
characteristic All MSO3000 models
All DPO3000 models
Maximum sampling rate (all channels) 2.5 GS/s
Maximum record length (all channels) 5 M points
The maximum duration captured at the highest sampling rate (for all channels) 2 ms
Time base range (S/div) 1 ns - 1000 s
Time base delay time range -10 grids to 5000 seconds
Channel to channel offset correction range ± 100 ns
Time base accuracy ± 10 ppm at 1 ms intervals
Horizontal system digital channel
characteristic All MSO3000 models
Maximum Sample Rate
(Main time base, all channels)
500 MS/s (2 ns resolution)
Maximum record length
(Main time base, all channels)
5 M points
Maximum Sample Rate
(MagniVu, all channels)
8.25 GS/s (121.2 ps resolution)
Maximum record length
(MagniVu, all channels)
10k points, centered around the trigger point
Minimum detectable pulse width 2.0 ns
Channel to channel offset Typical value of 500 ps
Bias range
range 1MΩ 50Ω,75Ω
1 mV/div - 99.5 mV/div ±1 V ±1 V
100 mV/div - 995 mV/div ±10 V ±5 V
1 V/div ±100 V ±5 V
1.01 V/div - 10 V/div ±100 V NA
Vertical System Digital Channel
characteristic All MSO3000 models
Number of input channels 16 digital channels (D15 to D0)
threshold Each set of 8 channels has a separate threshold set
Threshold selection TTL, CMOS, ECL, PECL, User defined
User defined threshold range -15 V to+25 V
Maximum input voltage -20 V to+30 V
Threshold accuracy ± (100 mV+3% threshold setting)
Maximum voltage swing 500 mVpk-pk
Input impedance 101 kΩ
Probe load 8 pF
Vertical Resolution 1 person
TRIGGER
characteristic describe
Main triggering mode Automatic trigger, normal trigger, and single trigger
Trigger coupling DC, AC, HF suppression (attenuation>50 kHz), LF suppression (attenuation<50 kHz), noise suppression (reduced sensitivity)
Trigger release range 20 ns - 8 s
Trigger sensitivity
Internal DC coupling 0.5 div at DC-50 MHz, increased to 1 div at rated bandwidth
External (auxiliary input) 200 mV at DC -50 MHz, increased to 500 mV at 250 MHz
Trigger level range
characteristic describe
Any channel ± 8 grids from the center of the screen
External (auxiliary input) ± 8 V
MODE
mode describe
edge Positive or negative slope on any channel or front panel auxiliary input. Coupling includes DC, AC, high-frequency suppression, low-frequency suppression, and noise suppression
Sequence (triggered by B) Trigger on time delay of -8 ns to 8 s, or trigger on event delay of -1 to 9999999 events
Pulse width Triggered on positive or negative pulse widths of>,<,=, or ≠ specific time periods
Short pulse Triggered when a pulse crosses a threshold but fails to cross the second threshold before crossing the first threshold again
logic When any logical code pattern in the channel becomes false or on a specified clock edge. When the code time type specified by the four input channels (A remains true) triggers acquisition. Any input can be used as a clock, with ND, OR, NAND, NOR defined as high, low, or indifferent
Establishment time/
HOLD
Triggered when the establishment time and holding time between the clock and data present in any two input channels exceed the threshold
Rise/fall time Trigger acquisition when the pulse edge rate is faster or slower than the specified value. The slope can be positive, negative, or any other value
video NTSC, PAL, and SECAM video signals trigger on all lines, odd, even, or all fields
Extended video (optional) Trigger 480 p/60, 576p/50, 720p/30, 720p/50,720p/60,875i/60, 1080i/50, 1080i/60, 1080p/24, 1080p/24sF,1080p/25,1080p/30, 1080p/50, 1080p/60 Customize dual level and three-level synchronous video standards
I2C (optional) On the I2C bus with a speed of up to 10 Mb/s, start, stop, ACK loss, address (7 or 10 bits), data or address and data trigger collection
SPI (optional) Trigger acquisition on SS, MOSI, MISO or MOSI and MISO on SPI bus up to 10.0 Mb/s (applicable only to 4-channel models).
CAN (optional) On CAN signals up to 1 Mb/s, the frame start, frame type (data, remote, error, overload), identifier (standard or extended), data, identifier and data, frame tail or ACK loss trigger collection. Further data can be specified to trigger collection when ≤,<,=,>, ≥ or ≠ specific data values. The sample points that users can adjust are set to 50% by default.
I2S/LJ/RJ/TDM (optional) Trigger Word Select, Frame Sync, or Data. You can specify data in one step, triggering collection when<,=,>, ≥, ≠ a certain data value or when it falls within or outside the range.
The maximum data rate of I2S/LJ/RJ is 12.5 Mb/s.
The maximum data rate for TDM is 25 Mb/s
RS-232/422/485/UART (optional) Trigger up to 10 Mb/s Tx start bit, Rx start bit, Tx packet tail 、 Rx packet tail, Tx data, Rx data, Tx parity error, and Rx parity error
LIN (optional) Triggering synchronization, identifiers, data, identifiers and data, wake-up frames, sleep frames, and errors (such as synchronization errors, parity errors, or checksum errors) up to 1 Mb/s (defined as 20 kb/s according to LIN)
Parallel (only available on MSO models) Trigger parallel bus data values. The parallel bus length can range from 1 bit to 16 bits. Supports binary and hexadecimal cardinality
Acquisition mode
sampling Collect sampling values
Peak detection Capture the narrowest 2 ns burr at all scanning speeds
average On average, it can include 2-512 waveforms
envelope The minimum maximum envelope reflects the peak detection data collected multiple times
Hi-Res Real time rectangular wave series averaging reduces random noise and improves resolution
Scroll Mode Scroll the waveform from right to left on the screen at a scanning speed of 40 ms/div or less
Waveform measurement
cursor Waveform and Screen
automatic measurement 229 types, of which up to 4 measurement functions can be displayed on the screen at once. Measurement includes cycle, frequency, delay, rise time, fall time, positive duty cycle, negative duty cycle, positive pulse width, negative pulse width, burst width, phase, positive overshoot, negative overshoot, peak to peak value, amplitude, high value m low value, maximum value, minimum value, average value, cycle mean, RMS, cycle RMS, area, and cycle area
Measurement statistics Mean, minimum, maximum, standard deviation
Reference level User definable automatic measurement reference levels can be specified in percentages or units
gate Use a screen or waveform cursor to isolate specific situations that occur within the collection to be measured. Measure using the entire record by default
Power measurement (optional)
power quality
measure
VRMS, V Crest Factor, Frequency, I RMS, ICrest Factor, real power, apparent power, reactive power, power factor, phase angle
Measurement of switch losses Power loss: Ton, Toff, conducted power loss, total power loss, energy loss: Ton, Toff, conducted energy loss, total energy loss
harmonic THD-F, THD-R, RMS measurement, harmonic graph and table display, according to IEC61000-3-2 Class A and MIL-STD-1399, standard testing
Ripple measurement Vripple and Iripple
modulation analysis Graphic display+Pulse Width, - Pulse Width, Period, Frequency,+Duty Cycle, and - Duty Cycle modulation types
Safe Operation Area Graphic display and template testing for measuring the safe working area of switchgear
DV/dt and dI/dt measurements Conversion rate cursor measurement
Waveform mathematical operation
algebraic operation Waveform addition, subtraction, multiplication, division
Mathematical functions Integral, Differential, FFT
FFT Spectral amplitude. Set the FFT vertical scale to linear RMS or dBV RMS, and set the FFT window to rectangular, Hamming, Hanning, or Blackman Harris
Advanced Mathematical Operations Define comprehensive algebraic expressions, including waveforms, reference waveforms, mathematical functions (FFT, Intg, Diff, Log, Exp, Sqrt, Sine, Cosine, Tangent), scalars, up to two user adjustable variables and parameter measurement results (Period, Freq, Delay, Rise, Fall, PosWidth, NegWidth, BurstWidth, Phase, PosDutyCycle, NegDutyCycle, PosOversoot, NegOversoot, PeakPeak, Amplitude, RMS, CycleRMS, High, Low, Max, Min, Mean, CycleMean, Area, CycleArea, and trend charts), such as (Intg (Ch1- Mean (Ch1)) x 1.414 x VAR1)
software
NI LabVIEWSignalExpressTMTektronix Edition A comprehensive interactive measurement software environment optimized for the MSO/DPO3000 series, which can use an intuitive drag and drop user interface to instantly collect, generate, analyze, compare, import, and save measurement data and signals without requiring any programming. The software provides standard DPO3000 series support for collecting, controlling, viewing, and exporting real-time signal data. The full version can be tried for free for 30 days, providing additional features such as signal processing, advanced analysis, mixed signals, scanning, extreme testing, and user-defined steps. Order SIGEXPTE to receive permanent full version functionality
OpenChoiceDesktop Quickly and easily communicate between Windows PC and DPO3000 series via USB or LAN. Transfer and save settings, waveforms, measurements, and screen images
IVI Driver Provide standard instrument programming interfaces for commonly used applications, such as LabVIEW, LabWindows/CVI, Microsoft. NET, and MATLAB
eScope Control MSO/DPO3000 through a standard web browser and network connection. Just enter the IP address or network name of the oscilloscope, and a webpage will be displayed in the browser
Display Features
display type 9-inch (228.6 mm) LCD TFT color display
Display resolution 800 horizontal x 480 vertical pixels (WVGA)
Waveform display style Vector, dot, variable afterglow, infinite afterglow
ruling All, grids, markings, boxes, IRE, and mV
format YT and XY
Waveform capture rate >50,000 wfm/s
Input/output ports
USB 2.0
High speed host port
Supports USB massive storage devices and printers. One on the back panel and one on the front panel
USB 2.0
High speed equipment port
The rear panel connector can be used to control the oscilloscope using USBTMC, GPIB, and TEK-USB-488, or directly printed onto a compatible PictBridge printer
LAN port RJ-45 connector, supports 10/100Base-T
Video Output Port DB-15 female connector, connected to an external monitor or projector to display oscilloscope images
auxiliary input Front panel BNC connector. Input impedance of 1 megaohm. Maximum input 300 V RMS, peak value ≤± 450 V
Probe compensator output not have
Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!