DM6100type
X-ray thickness gauge
used forSteel strip, copper strip, aluminum strip, aluminum foil, etcofNon contact onlineThickness measurement
The cost-effectiveness is significantly better than using isotopic radioactive sourcesriseThickness gauge for radiation source
The price is only one-fifth of similar foreign products
overview
DM6100 X-ray thickness gaugeIt can be used for measuring the thickness of various plastic films, rubber, wood, cardboard, metal sheets, etc. in various industries. It is mainly used for dynamic thickness measurement of products on production lines in various fields of the metal rolling industry, such as strip steel, copper strip, aluminum strip, aluminum foil, etc. It can output thickness signals to the AGC system to achieve closed-loop adjustment of thickness. It has the advantages of non-contact measurement, continuous, fast, and accurate measurement.
DM6100 X-ray thickness gaugeUsing an X-ray tube as the X-ray source has significant advantages compared to the majority of X-ray thickness gauges in China that currently use isotope radiation sources as the X-ray source. Firstly, it can eliminate the complex approval procedures, high management costs, and especially the cost of repurchasing radioactive sources from scrapped instruments caused by the use of isotopic radioactive sources. Secondly, this thickness gauge adopts the unique radiation source control technology developed by our company. The energy and intensity of its X-ray source are continuously adjustable, ensuring the best measurement accuracy for each thickness within the maximum measurement thickness range. Isotope radiation sources generally have only one energy, which can only guarantee the best measurement accuracy for a certain thickness.
At present, the vast majority of domestically produced X-ray thickness gauges use isotope radiation sources as X-ray sources, while X-ray thickness gauges using X-ray tubes as X-ray sources are mainly imported large-scale equipment with high prices. Although a few domestic enterprises have started production in recent years, their market share is limited and prices are also high. The DM6100 X-ray thickness gauge is a small thickness gauge that uses a small X-ray tube as the X-ray source. Although its performance is slightly inferior to imported products, its price is much lower than imported products and also lower than domestic peers. It is only similar to thickness gauges that use isotope radiation sources as X-ray sources, but its performance is much higher than that of thickness gauges that use isotope radiation sources as X-ray sources.
DM6100 X-ray thickness gaugeThe launch of this technology enables small and medium-sized enterprises in China that require thickness gauges to also use X-ray thickness gauges with X-ray tubes as radiation sources, providing users with a new and more optimized option. Users replacing X-ray thickness gauges with isotope radiation sources with DM6100 X-ray thickness gauges at similar prices will not only greatly improve product quality due to improved performance, thereby bringing great economic benefits to users, but also improve the domestic environmental protection level by not using isotope radiation sources, thereby bringing great social benefits to the country.
We believe that the DM6100 X-ray thickness gauge will soon replace X-ray thickness gauges that use isotope radiation sources as radiation sources and become the dominant force in the X-ray thickness gauge market.
characteristic
1. It does not contain isotopic radioactive sources, has no three waste pollution, and eliminates the trouble and cost for users.
2. Continuous non-contact measurement, connected to the AGC system, can achieve closed-loop control of thickness.
3. Large screen Chinese display, cold cathode backlit LCD, clear and bright handwriting.
4. High degree of integration, strong environmental adaptability, strong anti-interference ability, and high reliability.
5. High measurement accuracy, fast response speed, and good stability.
6. Easy and fast operation, with minimal maintenance and debugging workload.
7. It has self diagnosis, misoperation prompts, automatic calibration, and compensation functions.
8. Excellent shielding protection ensures radiation safety protection requirements.
9. Low price function ratio, suitable for China's national conditions.
Specification
1. Measurement range: 0.1mm~4.0mm (for steel), 0.01mm~10.0mm (for aluminum).
2. Running speed of steel strip: 0-27m/s.
3. Resolution accuracy: 0.001mm.
4. Measurement accuracy: ± 0.2%.
5. Response time: 100ms (63% response to 5% thickness change).
6. Sampling period: 200ms, 400ms, 600ms, 800ms can be selected.
7. Measurement noise: 0.12%.
8. Repeatability: 0.2%.
9. Drift: Long term drift<± 0.24% per 8 hours, short-term drift<± 0.2% per hour.
10. Preheating time: 1 hour after the X-ray source is turned on
11. Automatic calibration time: ≤ 20 minutes.
12. Material compensation range: 0-15% (or using multiple alloy calibration curves).
13. Usage conditions: Environmental temperature: 0~+40 ℃, relative humidity: ≤ 95% (30 ℃), power supply: 220V ± 20V, 50Hz.
14. Whole machine power consumption: ≤ 250W.
15. Size and weight:
Instrument control panel: 470mm × 365mm × 160mm, 15kg.
C-frame: 673mm × 579mm × 189mm, 35kg.
Ordering Information
DM6100typeXX-ray thickness gaugeThe main technical indicators of the standard type are as described above, and the external specifications and dimensions of the C-frame of the standard type are shown in Figure 1. If the user believes that the standard type can meet the measurement requirements, please choose the standard type as much as possible, because the standard type is produced in large quantities and has the cheapest price. In addition to the standard type, our company can provide non-standard X-ray thickness gauges to meet the requirements of the vast majority of users who need X-ray thickness gauges. The maximum voltage of the X-ray tube can be 90kV, 150kV, 250kV, and the maximum current can be 0.5mA, 1.0mA, 2.0mA, thereby increasing the measurement range to 25.0mm (for steel), the measurement accuracy to ± 0.05%, and the response time to 1ms. If there are special requirements, please contact us at Please provide the following information when placing an order:
Measurement Object |
Range of measurement |
rolling speed |
Strip width |
CDistance between the frame and the control panel |
|
|
|
|
|
measurement accuracy |
response time |
rolling temperature |
Other requirements1 |
Other requirements2 |
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|