Shanghai Aiste Electronics Co., Ltd
Home>Products>DM1230 X-ray Fluorescence Aluminum Silicon Analyzer
Product Groups
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
  • Address
    No. 169 Zhongfa Road, Zhujing Industrial Zone, Jinshan District, Shanghai
Contact Now
DM1230 X-ray Fluorescence Aluminum Silicon Analyzer
Simultaneous use with calcium iron analyzer to truly achieve rate control of raw material batching. Realize the function of X-ray fluorescence multi-e
Product details




DM1230type

X-ray fluorescence aluminum silicon analyzer




Calcium iron analyzerat the same timeUse and truly achieve rate control of raw material ingredients

Less thanhalfThe realization of investmentXFunctions of Fluorescence Multi Element Analyzer

Touch basedcolorHigh definition screen, multi-channel pulse analyzerWaiting for high-tech advancementsBig integration


overview


DM1230typeXFluorescence aluminum silicon analyzerIt is a quantitative analysis instrument developed in response to the requirements of cement enterprises, mainly used for measuring raw materials, clinker, cement and other materialsAl2O3SiO2The content. Currently, the majority of cement companies in China have adoptedXFluorescence calcium iron analyzer is used to measure the content of raw materials and other materialsCaOFe2O3The content, butAl2O3SiO2The measurement of content is rarely usedXThe fluorescence analyzer, andAl2O3SiO2Real time and accurate determination of contentCaOFe2O3The quality control of cement production is equally important, and only by simultaneously and accurately obtaining the content of these four oxides can the rate control of raw materials be truly achieved. So in the past few years, our company launched the DM2100 model that can truly be used in cement enterprisesXThe fluorescence multi-element analyzer has solved this problem, but in recent years, there have only been a few hundred users. Although it is not a small number, it is far behind the thousands of users of calcium iron analyzers. Of course, cement companies know how to use itXThe advantage of fluorescence analyzer lies in its price, although the DM2100 modelXThe price of a fluorescent multi-element analyzer is only one tenth of that of imported large instruments, but the price of tens of thousands still makes many small and medium-sized cement enterprises in China hesitate. They have repeatedly raised whether there is a measurement availableCaOFe2O3Instruments for measuring content. For this reason, our company quickly developed this product at a price of less thanDM2100halfXFluorescent aluminum silicon analyzer.

DM1230typeXFluorescence aluminum silicon analyzerOur company has been collecting data for decadesXThe research experience of fluorescence analyzer in the company's existingDMSeries calcium iron analyzerXA domestically developed X-ray fluorescence aluminum silicon analyzer without radioactive isotopes based on fluorescence multi-element analyzer and other technologies. Unlike traditional aluminum silicon analysis methods, it adopts physical analysis methods and has the characteristics of fast analysis speed, high accuracy, small human error, low labor intensity of operators, and no pollution. It only requires a one-time investment and does not require any chemical reagents. When this instrument is used together with our company's calcium iron analyzer, the same sample can be used, and because the sample prepared according to the requirements of this instrument is better than that required by the calcium iron analyzer, it can also be improvedCaOFe2O3The accuracy of content measurement, andDM2100typeXCompared to fluorescent multi-element analyzers, although it is a bit more complicated to use, the price is less than half, and due to its simple structure, it has higher reliability.

2014 DM1230 X-ray Fluorescence Aluminum Silicon AnalyzerExcept for maintaining the originalDMseriesXThe appearance of fluorescence analyzer is beautifulIn addition to the advantages of integration, continuous measurement standard sample method, and large data storage capacity, it also adopts a large screen color touch LCD screenThere is no data bus directly connected to the outsideCPUSurface mount circuits, adopting the latest designsCPLDFPGAHigh tech technologies such as multi-channel pulse amplitude analyzers and variable gain amplifiers. This is the latest achievement of our company's self transcendence.



Specification



1. Scope of analysis:Al2O3SiO2The analysis range can be adjusted and selected by calibrating the working curve.
2. Analysis range width:Al2O3maxAl2O3min≤5%SiO2 maxSiO2 min≤7%.
3. Linear error:Al2O3:≤0.14%SiO2:≤0.14%.
4. System analysis time:100In seconds200In seconds300Seconds, optional.
5. Analysis accuracy:SAl2O30.07%SSiO20.07%.
6. Temperature stability:exist5~+40Within the temperature range, absolute drift: ∣△Al2O3∣≤0.07%,∣△SiO2∣≤0.07%.
7. Usage conditions: Environmental temperature:5~+40℃, relative humidity: ≤85%(30℃)Power supply:220V±20V, five0Hz.
8. Power consumption of the whole machine: ≤ 50W.
9. Size and weight:470mm×365mm×130mm15kg.