DDSF601 single-phase electronic multi rate energy meter
Electric energy meter series, intelligent electric energy meter series, electronic electric energy meter series, prepaid electric energy meter series,
Product details



Specification and model:DDSF601
summary:

The DDSF601 single-phase electronic multi rate energy meter is an energy meter developed by our company using advanced international microelectronics technology and produced using modern production processes such as SMT wave soldering. The DDSF601 single-phase electronic multi rate energy meter can record the electricity consumed by users in different time periods according to the set multiple rate parameters. The meter can be set and read/written locally or remotely through an infrared programmer or RS485 interface, and long-distance electricity parameter collection can be established through the RS485 data network; Users can display relevant parameters in the electricity meter through the LCD screen. Electric energy meters have high measurement accuracy, high stability, and strong overload capacity. Long term use is safe and reliable, adaptable to a wide range of temperature environments, and easy to install. The use of LCD indicators for cumulative electricity consumption is particularly suitable for residential and industrial users for energy metering.
Technical indicators and parameters

Execution standards
GB/T 17215.321-2008 "Special Requirements for AC Measuring Equipment Part 21: Static Active Energy Meters (Class 1 and Class 2)
GB/T 15284-2002 "Special Requirements for Multi Rate Energy Meters"
DL/T645-1997 "Communication Protocol for Multifunctional Energy Meters"
reference frequency
50Hz
Working voltage range
0.8Un~1.15Un
Environmental temperature for use
-25℃~60℃
limiting ambient temperature
-40℃~70℃
relative humidity
85%
Voltage line power consumption
At the reference voltage, reference temperature, and reference frequency, the active power and apparent functional consumption of the voltage line of the energy meter should not exceed1.5W、10VA; Under communication conditions, it should not exceed 3W and 12VA.
The apparent power consumption of the current circuit of the energy meter should not exceed 1VA at the basic current, reference temperature, and reference frequency
major function
1. metering function
a) Capable of measuring active electrical energy
b) It has a time-sharing metering function, which accumulates and stores the total, peak, off peak, and valley electrical energy according to the corresponding time period.
c) Store at least 12 months of total electrical energy; The data storage boundary time is 24:00 of each month, or the hourly time between the 1st and 28th of each month;
d) When a power outage crosses the meter reading day and power is turned on, the energy data should be replenished.
2. Event record
a) The total number of programming attempts, the time of the last 10 programming attempts, operator code, and data identification of programming items should be recorded.
b) The total number of calibration times (excluding broadcast calibration), the time of the last 10 calibration times, and the operator code should be recorded.
3. Rate and Time Period
a) Having two sets of rate schedule, which can be automatically converted at the agreed time; Each set of rates should support at least 4 rates.
b) It should have a calendar and clock, and at least 2 time zones can be set throughout the year. Within 24 hours, at least 8 time periods can be programmed arbitrarily; The minimum interval between time periods is 15 minutes; The time period can be set across zero points.
4. Communication function with far-infrared communication and RS485 communication capabilities
5. Setting and Zeroing: After leaving the factory, it is not allowed to set the base degree or reset the energy meter to zero.
6. display function
a) It has the function of displaying data items such as battery level, date, and time, and the display content can be set through programming;
b) The LCD displays the cumulative electricity consumption, with the basic unit of energy value displayed being KWh. The numerical display has 8 digits and 2 decimal places;
c) The data items can be displayed in a cyclic manner through the buttons. When the buttons are pressed, the LCD should activate the backlight, which will automatically turn off after 60 seconds of inactivity when powered on;
d) Time display requirements for the period:
The date display format is year month day, separated by a ".", for example: YY.MM.DD.
The time is displayed in 24-hour format, separated by ":" between hours, minutes, and seconds, for example:
hh:mm:ss
e) Under normal working conditions, the energy meter supports infrared meter reading and infrared wake-up LCD screen backlight. The energy meter should wake up the backlight when receiving infrared signals from any infrared programmer or meter reader, regardless of whether communication is possible.
7. signal output
The electric energy meter should have LED pulse and electric pulse output functions proportional to the measured electric energy. The characteristics of the optical testing output device should comply with the requirements of GB/T17215.211-2006. The characteristics of the electrical test output device should comply with the requirements of GB/T15284-2002. Pulse width:
80ms ± 16ms.
Characteristics of electric pulse output port: When there is pulse output, the voltage drop of the pulse output port should not exceed 0.8V when passing through 5mA current; when there is no pulse output, the DC impedance of the pulse output port should not be less than 100K Ω.
The electric energy meter has multifunctional output terminals, which can achieve the output of second signal and time period switching signal through switching commands. The electric energy meter defaults to second signal output when powered on.
8. Timing function
Should have calendar, timing, and leap year automatic conversion functions; The output frequency of the internal clock terminal is 1Hz. Within the temperature range of -25 to 60 ℃, the clock accuracy is ≤±1.5s/d; At reference temperature (23)At ℃, the clock accuracy is ≤±1s/d
9. Freeze function
The electric energy meter can freeze the electric energy data according to the agreed time and interval; Each frozen amount should be saved at least 12 times, and the frozen content and corresponding data identification should comply with the requirements of DL/T645-2007 and its filing documents.
10. communication interface
a) Equipped with one modulated infrared interface and one RS485 communication interface; The physical layers of each communication interface are independent of each other, and damage to one communication interface should not affect other interfaces.
b) The baud rate designed for RS485 interface is 2400bps; The baud rate of the modulated infrared communication interface is 1200bps.
c) The communication protocol of the electric energy meter shall comply with DL/T645-2007 and its filing documents.
The electric energy meter supports both data item reading and data block reading in the DL/T645-2007 protocol. )
d) Infrared communication interface communication distance: ≥ 5m, communication angle; Above, to the left, and to the right of the central axis, θ ≥ 30 °, and below the central axis, θ ≥ 45 °.
e) The anti-interference performance of RS485 communication interface meets the requirements of DL/T614-2007.
Effective electrical isolation should be implemented between the RS485 communication interface and the internal circuit of the energy meter, and failure protection measures should be taken.
Dimensions (mm)
160×112×71
Installation size (mm)
100×150
Product specifications

model
Reference voltage (V)
Basic current (maximum current)
Pulse constant imp/KWh
accuracy class
DDSF601
220
1.5(6)A
12000
Level 1 or Level 2
5(20)A
3200
5(30)A
2400
10(40)A
1600
10(50)A
1600
10(60)A
1200
120(80)A
800