Precision air conditioning in the computer room20KW-100KW
hostTo have functional characteristics
365 days * 24 hours continuous and uninterrupted operation design, with low operating and maintenance costs
Fully intelligent constant temperature and humidity precision control system
Standard AC fan (optional EC fan), low noise, energy-saving and efficient
Air supply method: Upward air supply/downward air supply/sinking fan type
Cooling methods: air-cooled/water-cooled/chilled water, multiple models
Cabinet appearance and color consistent with IT room
High air volume and small enthalpy difference design, meeting the temperature control and humidity needs of the computer room, with high sensible heat ratio and low energy consumption
Equipped with call self start, delayed start, and phase sequence fault tolerance functions
7-inch true color full LCD touch screen, multi-level password design
Equipped with group control and rotation functions, automatic fault switching
Equipped with rapid dehumidification function
Standard water leakage alarm protection function
Standard A-type evaporator design (V-type or sheet type optional).
Rich internal detection, fault alarm, and protection functions
Standard RS485 communication interface
Optional Ethernet interface, supporting TCP/IP and SNMP protocols
-
Optional GPRS module, adding mobile APP function to enable on/off, setting, and temperature and humidity detection of mobile phones
Provide standard communication protocols
Rich optional functional components to adapt to special installation locations and functional requirements
Multiple application areas:
Computer rooms and data centers
Switching room, telecommunications room
UPS and battery room
Precision machining manufacturing center
Museums, archives
Measurement center, laboratory
Medical and testing room
Power equipment room
precautions
1. Design conditions: Indoor dry bulb temperature of 24 ℃, wet bulb temperature of 17 ℃; The outdoor dry bulb temperature is 35 ℃.
2. If there are special requirements for the air outlet method and air pressure, please specify them before placing an order.
3. The length of the connecting pipeline between indoor and outdoor units should be less than 30 meters, and the height difference should be less than 15 meters. If it exceeds this range, corresponding pipeline corrections should be made.
4. The above technical parameters indicate that the refrigerant is R22. If you need other environmentally friendly refrigerants, please specify before placing an order.
5. For other model parameters, please feel free to inquire by phone. Due to product updates, changes in relevant technical parameters will not be notified separately. Please understand.
-
Parameters of air-cooled precision air conditioner20-100KW