Circulating hot air blower
Circulating hot air blower
Product details

PID/SSR control, high precision, fast feedback, and long-lasting durability.

L is equipped with multiple overheating and overload protection devices to fully ensure equipment safety, and can operate continuously 365 days a year.

K-type thermocouple is installed at the air outlet for direct detection and control, ensuring a constant air temperature.

Multi fiber insulation cotton insulation, sturdy casing, safe and reliable use, can maintain high temperature operation for a long time.

The continuous use temperature can reach 350 ℃/450 ℃/500 ℃, and it is widely used.

The standard circulation type hot air blower adopts a patented design of the heat dissipation device, with a continuous inlet air temperature of up to 230 ℃/400 ℃. The air volume is regulated by a frequency converter, which is more energy-saving, highly controllable, and has excellent characteristics such as less heat loss.

There is also a remote switch (6m) and a fan casing anti burn insulation sleeve available for selection.

The standard circulating hot air blower adopts international brand electrical main controls (such as frequency converter, PID temperature controller, etc.), SSR, Circuit breakers, intermediate relays, magnetic switches, etc. The precision of the PID temperature controller is ± 0.5%, and it is equipped with a remote switch;

The economic circulation type hot air blower adopts international brand electrical main controls (such as PID thermostat, SSR, Circuit breakers, intermediate relays, magnetic switches, etc. are not equipped with frequency converters, but with motor protectors. The precision of PID temperature controller is ± 0.5%;

The practical circulating hot air blower adopts domestic brand electrical main controls (such as PID thermostat, SSR, Circuit breakers, intermediate relays, magnetic switches, etc. The precision of PID temperature controller is ± 0.5% Not equipped with a frequency converter, but equipped with a motor protector

B-type circulating hot air blower does not come with a temperature control unit device, only the fan and heating device

Model Description:


Example:

1: HWG-PR5A3-018-22 (Practical circulating hot air blower, electric heating power of 5KW, power supply of 3-phase 380V, motor of 250W, type 2 chassis); Equipped with temperature control configuration

2: HWG-PR20A3-3-41 (practical circulating hot air blower, electric heating power of 20KW, power supply of 3-phase 380V, motor of 3KW, type 4 chassis); Equipped with temperature control configuration

Practical circulating hot air blower parameter table


model

HWG-PR3A1-006-11

HWG-PR3A1-018-12

HWG-PR5A3-006-21

HWG-PR5A3-018-22

HWG-PR5A3-025-23

Power supply 50Hz

Single phase 220V

Single phase 220V

Three phase 380V

Three phase 380V

Electric heating power

3 kW

3 kW

5 kW

5 kW

inlet air temperature

Room temperature~230 ℃

Room temperature~230 ℃

Room temperature~230 ℃

Room temperature~230 ℃

Air outlet temperature

Room temperature~450 ℃

Room temperature~350 ℃

Room temperature~450 ℃

Room temperature~350 ℃

Diameter of air outlet accessories

2″(φ57)

2″(φ57)

21/2″(φ76)

21/2″(φ76)

21/2″(φ76)

wind

machine

power

60W

180W

60W

180W

250W

Maximum air volume

3.5m3/min

6.7m3/min

3.5m3/min

6.7m3/min

8.4m3/min

Maximum wind pressure

412Pa (full pressure)

450Pa (full pressure)

412Pa (full pressure)

450Pa (full pressure)

860Pa (full pressure)

noise

74dB

72 dB

74 dB

72 dB

74 dB

configuration

Power cord 3m long with heat-resistant fan

weight

20kg

30kg


model

HWG-PR7.5A3-006-24

HWG-PR7.5A3-018-25

HWG-PR7.5A3-025-26

HWG-PR10A3-025/055/075-31

HWG-PR15A3-025/055/075-32

Power supply 50Hz

Three phase 380V

Three phase 380V

Three phase 380V

Electric heating power

7.5 kW

7.5 kW

10 kW

15 kW

inlet air temperature

Room temperature~230 ℃

Room temperature~230 ℃

Room temperature~230 ℃

Air outlet temperature

Room temperature~450 ℃

Room temperature~350 ℃

Room temperature~350 ℃

Diameter of inlet/outlet accessories

3″

3″

3 "or 4"

wind

machine

power

60W

180W

250W

250w/550W/750W

Maximum air volume

3.5m3/min

6.7 m3/min

8.4m3/min

8.4m3/min / 14.5m3/min / 20.5m3/min

Maximum wind pressure

412Pa (full pressure)

450Pa (full pressure)

860Pa (full pressure)

860Pa (full pressure)/1050Pa (full pressure)/1250Pa (full pressure)

Configuration

74 dB

72 dB

74 dB

76 dB

Configuration

Power cord 3m long with heat-resistant fan

weight

30kg

42kg


model

HWG-PR20A3-1.5-41

HWG-PR25A3-1.5-42

HWG-PR30A3-2.2-43

HWG-PR35A3-2.2-44

HWG-PR45A3-3-45

HWG-PR60A3-3-46

Power supply 50Hz

Three phase 380V

Three phase 380V

Three phase 380V

Electric heating power

2x10 kW

2x12.5 kW

2x15 kW

2x17.5 kW

2x22.5kW

2x30 kW

inlet air temperature

Room temperature~230 ℃/400 ℃

Room temperature~230 ℃/400 ℃

Room temperature~230 ℃/400 ℃

Air outlet temperature

Room temperature~350 ℃/500 ℃

Room temperature~350 ℃/500 ℃

Room temperature~350 ℃/500 ℃

Diameter of inlet/outlet accessories

4 "or 5"

5 "or 6"

6 "or 8"

wind

machine

power

1.5kW

2.2kW

3.0kW

Maximum air volume

23m3/min

24m3/min

25m3/min

Maximum wind pressure

1.9kPa (total pressure)

2.1kPa (total pressure)

2.3 kPa (total pressure)

configuration

Power cord 3m long with heat-resistant fan

weight

124kg


Practical circulating hot air blower parameter table

Model: HWG-PR3A1-006-11; HWG-PR3A1-018-12; HWG-PR5A3-006-21

HWG-PR5A3-018-22; HWG-PR5A3-025-23; HWG-PR7.5A3-006-24

HWG-PR7.5A3-018-25; HWG-PR7.5A3-025-26

Function indicator diagram

dimension


model

A

B

C

D

E

F

G

H

I

J

K

L

M

N

P

HWG-PR3A1-006-11

268

192

340

274

196

89

50

262

100

90

90

77

192

150

195

HWG-PR3A1-018-12

268

192

340

274

196

89

50

262

100

125

135

87

196

150

305

HWG-PR5A3-006-21

380

202

388

386

206

133

50

293

100

90

90

77

192

150

195

HWG-PR5A3-018-22

380

202

388

386

206

133

50

293

100

125

135

87

196

150

305

HWG-PR5A3-025-23

380

202

388

386

206

133

50

293

100

125

135

110

154

150

305

HWG-PR7.5A3-006-24

380

202

388

386

206

133

50

293

100

90

90

77

192

150

195

HWG-PR7.5A3-018-25

380

202

388

386

206

133

50

293

100

125

135

87

196

150

305

HWG-PR7.5A3-025-26

380

202

388

386

206

133

50

293

100

125

135

110

154

150

305


Note: 006:60W; 018:180W; 025:250W motor

Model: HWG-PR10A3-025/055/075-31; HWG-PR15A3-025/055/075-32Function indicator diagram

dimension


model

A

B

C

D

E

F

G

H

I

J

K

L

HWG-PR10A3-025/055/075-31

502

240

440

120

326

120

80

340

102

121

108

110

130

150

131

142

130

150

131

142

HWG-PR15A3-025/055/075-32

502

240

440

120

267

120

80

340

102

121

108

110

130

150

131

142

130

150

131

142


Note: 250W/550W/750W motors

Model: HWG-PR20A3-1.5-41; HWG-PR25A3-1.5-42; HWG-PR30A3-2.2-43

HWG-PR35A3-2.2-44; HWG-PR45A3-3-45; HWG-PR60A3-3-46

Function indicator diagram

dimension


Model number

A

C

D

E

F

G

H

I

J

K

L

M

N

HWG-PR20A3-1.5-41

590

600

360

360

560

100

685

157

157

182

395

130

1200

HWG-PR25A3-1.5-42

HWG-PR30A3-2.2-43

590

600

360

360

560

100

685

157

157

182

395

130

1200

HWG-PR35A3-2.2-44

HWG-PR45A3-3-45

590

600

360

360

560

100

685

180

180

206

365

130

1200

HWG-PR60A3-3-46


Note: 1.5KW/2.2KW/3KW heat-resistant motor

Practical circulating hot air blower outlet size diagram (optional accessories)


model

A

B

C

HWG-PR3A1-006-11

φ57 /φ76

89

φ89

HWG-PR3A1-018-12

HWG-PR5A3-006-21

φ76 /φ89 /φ108

127

φ133

HWG-PR5A3-018-22

HWG-PR5A3-025-23

HWG-PR7.5A3-006-24

HWG-PR7.5A3-018-25

HWG-PR7.5A3-025-26

HWG-PR10A3-025/055/075-31

HWG-PR15A3-025/055/075-32

HWG-PR20A3-1.5-41

φ89 /φ108 /φ133 /φ159

152

φ219

HWG-PR25A3-1.5-42

HWG-PR30A3-2.2-43

HWG-PR35A3-2.2-44

HWG-PR45A3-3-45

HWG-PR60A3-3-46

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!