Changsha, high pressure switch JC-230, easy to install
Product features:
1. The products sell well in Europe, Japan, Southeast Asia, Taiwan and Chinese Mainland
2. 3S pressure switches are widely used in industries such as refrigeration and water treatment
3. Refrigerants that can be used for water, air, and fluorination treatment
4. The allowable liquid temperature is -40~135 ℃
5. Micro switches have good reliability and long lifespan
6. Provide installation bracket
Changsha, high pressure switch JC-230, easy to installProduct model:JC-200 JC-201 JC-202 JC-203JC-206 JC-210 JC-215 JC-220 JC-230
Product parameters:
Unit: bar
|
model
|
adjustment range
|
Switch pressure difference
|
Factory settings
|
Airtight test pressure
|
Weight (kg) 0.42
|
|||
|
*Small
|
Zui Big
|
*Small
|
Zui Big
|
Off 0ff (on)
|
Turn on (off)
|
|||
|
JC-200
|
-1
|
0
|
0.2
|
0.5
|
-0.6
|
-0.3
|
11
|
|
|
JC-201
|
-1
|
1
|
0.2
|
0.5
|
-0.5
|
-0.3
|
11
|
|
|
JC-202
|
-0.5
|
2
|
0.5
|
0.7
|
0.5
|
1
|
11
|
|
|
JC-203
|
-0.5
|
3
|
0.35
|
2
|
0.5
|
1.5
|
11
|
|
|
JC-206
|
-0.5
|
6
|
0.6
|
4
|
2
|
3
|
16.5
|
|
|
JC-210
|
1
|
10
|
1
|
3
|
4
|
6
|
16.5
|
|
|
JC-215
|
3
|
15
|
2
|
5
|
9
|
12
|
25
|
|
|
JC-220
|
5
|
20
|
3
|
5
|
12
|
15
|
40
|
|
|
JC-230
|
5
|
30
|
3
|
10
|
15
|
20
|
||
Changsha, high pressure switch JC-230, easy to installelectrical rating:
|
Rated current (a)/rated voltage (V)
|
AC125V
|
AC250V
|
|
Non induced current
|
10A
|
**
|
|
Induced current
|
8A
|
4A
|
|
Zui high load
|
8.5
|
4.5
|
|
start
|
40
|
20
|
|
Protection level
|
IP56
|
IP56
|
The 3S pressure switch is mainly used to measure the pressure status of liquids (water and fluorinated refrigerants) or air flowing through pipelines, and its typical application is to display and control pressure. The mechanical life of the 3S pressure switch is ≥ 100000 times (reference value JC series ≥ 400000 times)
Changsha, high pressure switch JC-230, easy to install
Setting value adjustment method:
When the accuracy requirement for the set value is not high, it can be debugged according to the controller scale and the pressure gauge in the system. When the set value requirement is high, please use a dedicated pressure calibrator and precision pressure gauge for debugging. (There is a high-sensitivity single pole double throw proximity switch installed inside the pressure switch. The switch can set two switching values, usually referred to as the upper limit switching value and the lower limit switching value.)
Specific debugging methods:
The right adjustment screw on the top of the pressure switch directly adjusts the upper limit switching value;
The left adjustment screw on the top of the pressure switch is used to adjust the pressure difference of the switch;
3. Their relationship is: upper limit switching value - switch pressure difference=lower limit switching value
That is, the upper limit switching value can be directly adjusted on the ruler, and the lower limit switching value needs to be adjusted through 1-3 operations
Changsha, high pressure switch JC-230, easy to install
instructions:
1: The controlled medium should have no corrosive effect on brass, tin bronze, and lead tin solder.
2: When installing the controller cover, do not turn the internal screws or pull out the internal parts (except for the wiring screws).
3: The pressure of the controlled medium should not exceed the maximum allowable pressure specified in the table.