CYWL-100AP IoT Circuit BreakerIt is a multifunctional IoT intelligent switch that integrates power metering, overload, short circuit, overvoltage and undervoltage, leakage, over temperature protection, remote switching, and network communication functions; And all data can be freely set, with a high-definition LCD screen displaying the current product status. It can be widely used in intelligent electricity management places such as commercial, agricultural water conservancy, fire data collection, schools, hospitals, rental apartments, etc; It can also be widely applied in industry, especially in energy consumption management of factory equipment. The CYWL-100AP IoT circuit breaker can monitor and detect the user's load power consumption in real time. In case of abnormal situations, it can quickly and automatically cut off the power or remotely alarm, protecting personal and property safety.
It can implement a split charging mode and transmit data and execute related instructions through GPRS, RJ45, WIFI, RS485 encrypted forms.
The operation status and data of the network version switch can be permanently saved, and past usage can be viewed at any time.
The overcurrent, voltage, and leakage current protection values can be set arbitrarily, which can better protect the circuit of the load end equipment and achieve multi use without the need to replace the equipment.
The self inspection time of the product can be set arbitrarily to ensure that the product is always in normal working condition.
You can freely set the working time period of the product.
2、 Main functions and features
1. OLED dot matrix liquid crystal display, long lifespan, good low-temperature characteristics
2. It can be set as a communication gateway, and the shunt small current switch can be combined and networked through the 485 interface of the main body;
3. It integrates multiple protection functions such as overvoltage, undervoltage, phase loss, phase error, voltage loss, overload, short circuit, leakage, temperature, voltage/current imbalance, over power and under power, and anti-theft, and supports warning according to preset proportions
4. Multiple functions can be combined with shutdown, alarm, and alarm, making it more widely applicable
5. RS485 supports DL/T-645/Modbus protocol and automatically converts in non gateway mode;
6. Support external node control and achieve cabinet door control;
7. Support multiple sets of arbitrary time timers to control closing and opening operations, making control more flexible;
8. Multi component modular design, which can be selectively matched and used more flexibly;
9. Remote wireless communication technology, supporting multiple communication modes such as NB, 2G, 4G, etc;
10. Real time reporting of operation events, alarm events, fault events, allowing you to understand the operating status of your equipment anytime and anywhere; The alarm can be prompted by a buzzer and can be silenced remotely or locally, making the device alarm more intelligent
11. Supports multiple remote OTA upgrade modes, eliminating the hassle of device upgrade and maintenance;
12. Hundreds of local event records (power on, power off) are stored and can be viewed at any time for accident cause analysis;
13. The clock is synchronized with the cloud on a daily basis to ensure the accuracy of event recording time, with a daily error of no more than 1 second in the absence of a network
14. Real time statistics of the number of events can focus on frequent anomalies and support switching between Chinese and English displays;
15. Support 12-month frozen energy and 7-day daily frozen energy query, making remote energy consumption management more convenient;
16. Support the collection and uploading of electrical parameters such as active power, reactive power, apparent power, and power factor;
17. Support positive and negative energy statistics.
3、 Main technical parameters and basic functions
Product categories: 1. Single machine version (Rs485) 2. Network version (4G+RS485) 3. Customer demand customization (NB-Lot2GRJ45, etc.)
Number of product poles: 1P+N3P+N
Rated voltage: single-phase AC230V, three-phase Ac400V50Hz
Mechanical lifespan: greater than 20000 cycles
Electrical lifespan: greater than 10000 cycles
Closing and opening time: The closing time is less than 18 seconds;
The opening time is less than 1 second
Instant release type: C-type (other types, customizable)
Rated current: 40A, 63A, 100A
Compliant with standard: GB/T10963.1GB/T16917.1
Short circuit breaking capacity: ≥ 6KA
Short circuit protection: When the circuit is short circuited, the circuit breaker provides 0.01s power-off protection
Leakage protection: When there is a leakage in the circuit, the circuit breaker provides 0.1s power-off protection
Leakage protection value: 30~500mA can be set
Overvoltage protection: When the line is under voltage, the circuit breaker can be set to disconnect after 3 seconds (0~99 seconds)
Overvoltage setting value: 250~320V, undervoltage setting value: 100~200V
Power on delay: When a call is received, it automatically closes and can be set from 0 to 99 seconds
Power outage delay: When the power grid suddenly loses power, the circuit breaker is in the open state and can be set from 0 to 10 seconds
Rated current setting: 0.6~1ln
Overload delay protection: adjustable from 0 to 99 seconds
Overtemperature protection: adjustable from 0 to 120 ℃, circuit breaker disconnect time adjustable from 0 to 99 seconds
Under power: The amount of load change can be set, and the circuit breaker opening time can be set from 0 to 99 seconds
Overpower: The amount of load change can be set, and the opening time of the circuit breaker can be set from 0 to 99 seconds
Power limit: When the limited power is reached, the circuit breaker will cut off power after 3 seconds (0-99 seconds can be set)
Timer control: adjustable, the body can set 5 sets of time imbalance: both voltage and current can be set as percentages, and the protection time can be set from 0 to 99 seconds
Record: 680 switch events can be queried locally
Log display: Chinese and English menus
Frequency: Record the number of various operations of the circuit breaker to determine whether it is within its effective lifespan
Maintenance: can perform self check, device reset, battery reset, record reset, clock synchronization, device restart, restore system defaults, etc. View: locally can view voltage, current, leakage current, temperature, active power, reactive power, apparent power, power factor, cumulative power, daily electricity consumption (view 7-day records)
Hand automatic integrated control: controlled by mobile APP or PC, can be controlled by buttons or through push rods (handle control for on/off; cover plate, pull rod: with anti electricity theft and maintenance anti misoperation mechanical interlocking function)
Communication method: RS485 standard, with options for 2G/4G, WIFI, NB, RJ45, etc
Software remote upgrade: programs can be customized according to actual usage to achieve remote updates and upgrades
The following functions can be set to enable, disable, alarm, or trip
Overvoltage protection, undervoltage protection, leakage protection, overload protection, automatic closing, power-off protection, underpower protection, warning function, timed self check, alarm permission, gear return, high temperature protection, sudden change protection, remote control, cover opening protection, underload protection, overpower protection, timed control, phase loss protection, phase fault protection, voltage imbalance, current imbalance