CQB-G type high-temperature insulation magnetic pump
Overview: CQB-G high-temperature magnetic pump is widely used in industries such as petroleum, chemical, metallurgy, food, water treatment, national d
Product details

Overview of CQB-G High Temperature Insulated Magnetic Pump

The CQB-G high-temperature insulation magnetic driven centrifugal pump (referred to as high-temperature magnetic pump) consists of four main parts: a motor, a magnetic coupling water cooling device, and a corrosion-resistant centrifugal pump. Its main feature is the use of a magnetic coupling to transmit power without any leakage. When the motor drives the outer magnetic steel of the magnetic coupling to rotate, the magnetic field lines pass through the gap and isolation sleeve, acting on the inner magnetic steel, causing the pump rotor to rotate synchronously with the motor and transmit torque without mechanical contact. At the power input end of the pump, due to the liquid being enclosed in a stationary isolation sleeve without a dynamic seal, there is no leakage. The magnetic material of the magnetic coupling uses a high-temperature medium to maintain a strong magnetic torque. A water cooling device has been installed between the motor and the magnetic coupling to prevent heat transfer from the pumped high-temperature medium to the motor. To maintain the normal operation of the motor and achieve leak free transportation of high-temperature media.

The CQB-G high-temperature insulation magnetic pump adopts a multiple circulation cooling structure to ensure the reliability and stability of the original power and magnetic transmission. At the same time, the use of column pin coupling reduces the noise and vibration of the pump. The detachable and column pin coupling are used simultaneously, which increases the structure of the pump and is more conducive to the heat dissipation of the pump. At the same time, it is also very convenient for users to repair or replace parts. A cooling fan blade is also designed on the outer rotor of the pump to ensure the stability of the magnetic steel. This series of pumps is suitable for transporting high-temperature media with a temperature of 300 ℃.

CQB-G high-temperature magnetic pump is widely used in industries such as petroleum, chemical, metallurgy, food, water treatment, national defense, pharmaceuticals, electroplating, and environmental protection. It is an ideal equipment for transporting high-temperature flammable, explosive, volatile, toxic, rare and valuable liquids as well as various corrosive liquids. Suitable for liquids with a working pressure of less than 1.6MPA, a temperature not exceeding 100 degrees, a density not exceeding 1600KG/M, and a viscosity not exceeding 30, which do not contain hard particles or fibers.

CQB-G high-temperature magnetic pump, suitable for conveying systems with working pressure less than 1.6MPa, temperature not exceeding 280 degrees, density not exceeding 1840kg/m3, viscosity not exceeding 30cm2/S for liquids without hard particles and fibers

The significance of CQB-G high-temperature insulation magnetic pump model


Performance parameters of CQB-G high-temperature insulation magnetic pump

Model number
caliber
internet traffic
(m3/h)
Head lift

Residual grain caused by cavitation
(NPSH)r(m)

Motor Power
KW
rotational speed
(r/min)
voltage
(V)
Import (mm)
Export (mm)
CQB32-20-125G
32
20
3.2
20
4.5
1.5
2900
380
CQB32-20-160G
32
4.5
2.2
2900
380
CQB40-25-125G
40
25
6.3
20
4.5
2.2
2900
380
CQB40-25-160G
32
4.5
3
2900
380
CQB40-25-200G
50
4.5
5.5
2900
380
CQB50-32-125G
50
32
12.5
20
4.0
3
2900
380
CQB50-32-160G
32
4.0
4
2900
380
CQB50-32-200G
50
4.0
7.5
2900
380
CQB50-32-250G
80
4.0
15
2900
380
CQB65-50-125G
65
50
25
20
4.0
5.5
2900
380
CQB65-50-160G
32
4.0
7.5
2900
380
CQB65-40-200G
40
50
4.0
15
2900
380
CQB65-40-250G
80
4.0
22
2900
380
CQB80-65-125G
80
65
50
20
3.5
7.5
2900
380
CQB80-65-160G
32
3.5
15
2900
380
CQB80-50-200G
50
50
3.5
22
2900
380
CQB80-50-250G
80
3.5
37
2900
380
CQB100-80-125G
100
80
100
20
3.2
15
2900
380
CQB100-80-160G
32
3.2
22
2900
380
CQB100-65-200G
65
50
3.2
37
2900
380
CQB100-65-250G
80
3.2
55
2900
380

Structure diagram

Installation size

Installation, use and maintenance

Installation and Commissioning

1. The high-temperature magnetic pump should be installed horizontally, and the lubricating oil level in the cooling box should be checked before driving. If the oil level is too low, it should be replenished in a timely manner. Before starting the pump, the cooling water circuit should be opened first, and the opening degree of the inlet pipe valve should be adjusted according to the temperature of the cooling outlet pipe after the pump is working normally.

2. When the suction liquid level is higher than the pump axis line, open the suction pipeline valve before starting. If the suction liquid level is lower than the pump axis line, the pipeline needs to be equipped with a bottom valve.

3. Before using the pump, it should be checked that the motor fan blades rotate flexibly, without jamming or abnormal noise, and all fasteners should be tightened.

4. Check if the rotation direction of the motor is consistent with the direction mark of the magnetic pump.

5. After the motor starts, slowly open the discharge valve and adjust it to the desired opening after the pump enters normal operation.

6. Before the pump stops working, the discharge valve should be closed first, then the power should be cut off, and finally the cooling water pipe valve should be closed.

Precautions for use

1. Due to the fact that the cooling and lubrication of magnetic pump bearings rely on the medium being transported, it is absolutely forbidden to stop idling, and at the same time, to avoid spatiotemporal load rotation caused by restarting after a power outage during operation.

2. If the conveyed medium contains solid particles, a filter screen should be added to the pump inlet; If it contains ferromagnetic particles, a magnetic filter should be added.

3. The conveyed medium and its temperature should be within the allowable range of the pump material. The working temperature of the pump is less than 280 ℃, the maximum working pressure is 1.6MPa, the density is not more than 1840kg/m3, and the viscosity is not more than 30cm2/S, which is a liquid without hard particles and fibers. Special working conditions should be strictly in accordance with the provisions of the contract agreement.

4. For media that are prone to precipitation and crystallization during transportation, they should be cleaned promptly after use to drain the accumulated liquid in the pump

5. After 1000 hours of normal operation of the magnetic pump, the wear of the bearings and end face moving rings should be disassembled and inspected, and vulnerable parts that are no longer suitable for use should be replaced.

6. The magnetic couplings inside and outside this series of pumps are made of high-performance permanent magnet materials, which may pose potential hazards to the following components. Please keep the following components at a distance from this series of pumps. Such as pacemakers, credit cards and other magnetic cards, calculators, computer disks, watches, etc.

Faults and troubleshooting methods

Fault phenomenon

cause analysis

Troubleshooting

The pump is not producing water

1. Reverse rotation of water pump

2. Air leakage in the inlet pipe

3. Insufficient water storage in the pump chamber

4. Voltage too high, coupling slips during startup

5. The suction distance is too high

6. The valve is not open

1. Adjust the direction of motor rotation

2. Eliminate air leakage

3. Increase water storage capacity

4. Adjust voltage

5. Lower the installation position of the pump

6. Correct or change the valve

Insufficient traffic

1. Suction pipe diameter size or blockage

2. Impeller channel blockage

3. Head too high

4. Insufficient rotational speed

1. Replace or clean the inlet pipe

2. Clean the impeller

3. Turn up the outlet valve

4. Restore rated speed

Low head

1. Excessive traffic

2. The speed is too low

1. Turn down the outlet valve

2. Restore rated speed

The shower noise is too loud

1. The pump shaft is severely worn

2. Severe wear of bearings

3. External magnetic steel or internal magnetic steel in contact with the isolation sleeve

4. Grinding of sealing ring and impeller

5. Wear of rolling bearings inside the cooling box

1. Replace the pump shaft

2. Replace bearings

3. Dismantle the pump head and reassemble it

4. Replace the thrust ring and sealing ring

5. Replace rolling bearings

Leakage of liquid

1. O-ring damaged

1. Replace the O-ring seal

Ordering Instructions

1、 ① High temperature insulation magnetic pump product name and model ② High temperature insulation magnetic pump diameter ③ High temperature insulation magnetic pump head (m) ④ High temperature insulation magnetic pump flow rate ⑤ High temperature insulation magnetic pump motor power (KW) ⑥ High temperature insulation magnetic pump speed (r/min) ⑦ High temperature insulation magnetic pump pressure [V] ⑧ High temperature insulation magnetic pump suction stroke (m) ⑨ Whether the high temperature insulation magnetic pump comes with accessories for us to correctly select for you.

2、 If the design unit has already selected our company's high-temperature insulation magnetic pump product model, please order directly from the sales department according to the high-temperature insulation magnetic pump model.

3、 When the usage situation is very important or the environment is complex, please provide design drawings and detailed parameters as much as possible, and our technical experts will review and control them for you.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!