Wenzhou Hongling Pump Valve Co., Ltd
Home>Products>CQ explosion-proof stainless steel magnetic pump
Firm Information
  • Transaction Level
    VIP member
  • Contact
  • Phone
    15868533002
  • Address
    Puxi Industrial Zone, Oubei Town, Yongjia County, Zhejiang Province
Contact Now
CQ explosion-proof stainless steel magnetic pump
Overview: CQ explosion-proof stainless steel magnetic pump has a compact structure, beautiful appearance, small volume, low noise, reliable operation,
Product details

Overview of Stainless Steel Magnetic Pump Products

CQ type stainless steel magnetic pump (referred to as magnetic pump) is a new product that applies the working principle of permanent magnet coupling to centrifugal pumps. It has a reasonable design, advanced technology, fully sealed, leak free, and corrosion-resistant characteristics, and its performance has reached the advanced level of similar foreign products.

Main characteristics of stainless steel magnetic pump

Magnetic pumps replace dynamic seals with static seals, ensuring that the overcurrent components of the pump are in a completely sealed state, completely solving the problems of running, emitting, and dripping that cannot be avoided by mechanical seals of other pumps. Magnetic pumps use corrosion-resistant and high-strength engineering plastics, steel jade ceramics, and stainless steel as manufacturing materials, so they have good corrosion resistance and can protect the transported medium from pollution.

Application of stainless steel magnetic pump products

Magnetic pump has a compact structure, beautiful appearance, small volume, low noise, reliable operation, and easy use and maintenance. It can be widely used in chemical, pharmaceutical, petroleum, electroplating, food, national defense, scientific research institutions, metallurgy, dyes and other units to pump acid, alkali solution, rare and valuable oil liquids, venom, volatile liquids, as well as supporting circulating water equipment and filter machines. Especially for the pumping of liquids that are prone to leakage, combustion, and explosion. This pump is a more ideal equipment for explosion-proof motors.

The significance of stainless steel magnetic pump model


Performance parameter table of stainless steel magnetic pump

Model number

caliber

Flow rate (m3/h)

Head (m)

Motor power (kW)

Voltage

(V)

Material

Import (mm)

Export (mm)

14CQ-5

14

10

1.2

5

0.12

220/380

without

rust

steel

16CQ-8

16

12

1.8

8

0.18

220/380

20CQ-12

20

12

3

12

0.37

220/380

25CQ-15

25

20

5.4

15

1.1

380

32CQ-15

32

25

6.5

15

1.1

380

32CQ-25

32

25

4.8

25

1.1

380

40CQ-20

40

32

10

20

2.2

380

40CQ-32

40

32

11.5

32

4

380

50CQ-25

50

40

14.4

25

4

380

50CQ-32

50

40

13.2

32

4

380

50CQ-50

50

32

7.8

50

5.5

380

65CQ-25

65

50

16.8

25

5.5

380

65CQ-32

65

50

25

32

7.5

380

80CQ-32

80

65

50

32

11

380

50CQ-50

80

65

50

50

15

380

100CQ-32

100

80

60

32

15

380

100CQ-50

100

80

60

50

18.5

380

Note: 16CQ-8 to 100CQ-50 in the table can all be equipped with explosion-proof motors

Structural diagram of stainless steel magnetic pump

 

Stainless steel magnetic pump installation size table

Stainless steel magnetic pump installation size table

Characteristic curve diagram

Installation and use of stainless steel magnetic pump

1. The magnetic pump should be installed horizontally and not vertically. The plastic pump body should not bear the weight of the pipeline. For special requirements for vertical installation, the motor must face upwards.

When the suction liquid level is higher than the pump axis line, open the suction pipeline valve before starting. If the suction liquid level is lower than the pump axis line, the pipeline needs to be equipped with a bottom valve.

3. Before using the pump, it should be checked that the motor fan blades rotate flexibly, without jamming or abnormal sound, and all fasteners should be tightened.

4. Check if the rotation direction of the motor is consistent with the direction mark of the magnetic pump.

5. After the motor is started, slowly open the discharge valve and wait for the pump to enter normal working condition before adjusting the discharge valve to the desired opening.

Before the pump stops working, the discharge valve should be closed first, and then the suction pipe valve should be closed.

Precautions for use

1. As the cooling and lubrication of the magnetic pump bearings rely on the medium being transported, it is absolutely forbidden to operate them without load, and at the same time, it is necessary to avoid idle operation caused by restarting after a power outage during operation.

If the conveyed medium contains solid particles, a filter screen should be added to the pump inlet. If it contains ferromagnetic particles A magnetic filter needs to be added. 3. The ambient temperature of the pump during use should be less than 40 ℃, and the temperature rise of the motor should not exceed 75 ℃.

4. The conveyed medium and its temperature should be within the allowable range of the pump material. The operating temperature of engineering plastic pumps is less than 60 ℃, the operating temperature of metal pumps is less than 100 ℃, the auxiliary suction pressure is not greater than 0.2MPa, the high working pressure is 1.6MPa, the density is not greater than 1600 ^ kg/m3, and the particle size is not greater than 30 X 10-6 ㎡/S of liquid without hard particles and fibers.

5. For media that are prone to precipitation and crystallization during transportation, they should be cleaned promptly after use and the accumulated liquid in the pump should be drained.

After 500 hours of operation of the magnetic pump, the wear and inertia of the bearings and end face dynamic rings should be inspected. If the gap between the bearings and the shaft sleeve is greater than 0.5-1mm and the impeller moves axially by 1.5-2mm, the bearings and axial dynamic rings should be replaced.

Malfunctions and troubleshooting

failure mode

cause

Troubleshooting

The pump is not producing water

Reverse rotation of water pump

Leakage of water pipeline

Insufficient water storage in the pump chamber

The voltage is too high, causing the coupling to slip during startup

The suction distance is too high

Change the motor wiring

Social isolation leakage

Increase storage capacity

Adjust the positive voltage

Lower the installation position of the pump

Insufficient traffic

The suction pipe diameter is too small

Impeller channel blockage

Head too high

The speed is too low

Replace the inlet pipe

Clean the impeller

Turn up the outlet valve

Rated speed of Huixia

Low head

Excessive traffic

The speed is too low

Turn down the outlet valve

Restore rated speed

The sound is too loud

Severe wear of the shaft

Severe wear of the shaft sleeve

Drive the magnetic steel cup to contact the isolation sleeve

Replace the pump shaft

Replace the shaft sleeve

Dismantle the pump head and reassemble it

Leakage of liquid

Type 0 sealing ring damaged

Replace the 0-type sealing ring

Corrosion resistance of materials (for reference)


Media name

concentration

%

polypropylene

concentration

%

ABC

25℃

50℃

20℃

60℃

Sulfuric acid

60



×

Nitric acid

25



O

Hydrochloric acid

<36



Fluorofluoric acid

35



×

acetic acid

<80



O

sodium hydroxide

100



potassium dichromate

25



bromine water




O

×

ethanol




acetone


×



O


Tetrachloroethane


O



O

×

Freon 22




O

O

bleaching solution

CL13%



O

O

Electroplating solution




O

×

Photographic liquid






Media name

concentration

stainless steel

concentration

ceramics

%

25℃

50℃

%

25℃

80℃

sulfuric acid

<5

X


V

V

nitric acid

7070

V


V

V

hydrochloric acid


X



V

V

Fluorofluoric acid


X


0~100

X


acetic acid

<20


V

V

sodium hydroxide

70


0

X

potassium dichromate

40~60

V

V

10~20

V

V

bromine water


0



V

V

ethanol


V


V

V

acetone


V

V


V


Tetrachloroethane

50

V

V


V

V

Freon 22


V



V

V

bleaching solution

C112%

X



V

V

Electroplating solution





V

V

Photographic liquid


V



V

V

Symbol Description: V - Excellent V - good, 0- usable But the corrosion is obvious X - severe corrosion, not applicable.

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!