Overview of Stainless Steel Magnetic Pump Products
CQ type stainless steel magnetic pump (referred to as magnetic pump) is a new product that applies the working principle of permanent magnet coupling to centrifugal pumps. It has a reasonable design, advanced technology, fully sealed, leak free, and corrosion-resistant characteristics, and its performance has reached the advanced level of similar foreign products.
Main characteristics of stainless steel magnetic pump
Magnetic pumps replace dynamic seals with static seals, ensuring that the overcurrent components of the pump are in a completely sealed state, completely solving the problems of running, emitting, and dripping that cannot be avoided by mechanical seals of other pumps. Magnetic pumps use corrosion-resistant and high-strength engineering plastics, steel jade ceramics, and stainless steel as manufacturing materials, so they have good corrosion resistance and can protect the transported medium from pollution.
Application of stainless steel magnetic pump products
Magnetic pump has a compact structure, beautiful appearance, small volume, low noise, reliable operation, and easy use and maintenance. It can be widely used in chemical, pharmaceutical, petroleum, electroplating, food, national defense, scientific research institutions, metallurgy, dyes and other units to pump acid, alkali solution, rare and valuable oil liquids, venom, volatile liquids, as well as supporting circulating water equipment and filter machines. Especially for the pumping of liquids that are prone to leakage, combustion, and explosion. This pump is a more ideal equipment for explosion-proof motors.
The significance of stainless steel magnetic pump model
Performance parameter table of stainless steel magnetic pump
Model number |
caliber |
Flow rate (m3/h) |
Head (m) |
Motor power (kW) |
Voltage (V) |
Material |
|
Import (mm) |
Export (mm) |
||||||
14CQ-5 |
14 |
10 |
1.2 |
5 |
0.12 |
220/380 |
without rust steel |
16CQ-8 |
16 |
12 |
1.8 |
8 |
0.18 |
220/380 |
|
20CQ-12 |
20 |
12 |
3 |
12 |
0.37 |
220/380 |
|
25CQ-15 |
25 |
20 |
5.4 |
15 |
1.1 |
380 |
|
32CQ-15 |
32 |
25 |
6.5 |
15 |
1.1 |
380 |
|
32CQ-25 |
32 |
25 |
4.8 |
25 |
1.1 |
380 |
|
40CQ-20 |
40 |
32 |
10 |
20 |
2.2 |
380 |
|
40CQ-32 |
40 |
32 |
11.5 |
32 |
4 |
380 |
|
50CQ-25 |
50 |
40 |
14.4 |
25 |
4 |
380 |
|
50CQ-32 |
50 |
40 |
13.2 |
32 |
4 |
380 |
|
50CQ-50 |
50 |
32 |
7.8 |
50 |
5.5 |
380 |
|
65CQ-25 |
65 |
50 |
16.8 |
25 |
5.5 |
380 |
|
65CQ-32 |
65 |
50 |
25 |
32 |
7.5 |
380 |
|
80CQ-32 |
80 |
65 |
50 |
32 |
11 |
380 |
|
50CQ-50 |
80 |
65 |
50 |
50 |
15 |
380 |
|
100CQ-32 |
100 |
80 |
60 |
32 |
15 |
380 |
|
100CQ-50 |
100 |
80 |
60 |
50 |
18.5 |
380 |
|
Note: 16CQ-8 to 100CQ-50 in the table can all be equipped with explosion-proof motors |
Structural diagram of stainless steel magnetic pump
Stainless steel magnetic pump installation size table

Stainless steel magnetic pump installation size table

Characteristic curve diagram

Installation and use of stainless steel magnetic pump
1. The magnetic pump should be installed horizontally and not vertically. The plastic pump body should not bear the weight of the pipeline. For special requirements for vertical installation, the motor must face upwards.
When the suction liquid level is higher than the pump axis line, open the suction pipeline valve before starting. If the suction liquid level is lower than the pump axis line, the pipeline needs to be equipped with a bottom valve.
3. Before using the pump, it should be checked that the motor fan blades rotate flexibly, without jamming or abnormal sound, and all fasteners should be tightened.
4. Check if the rotation direction of the motor is consistent with the direction mark of the magnetic pump.
5. After the motor is started, slowly open the discharge valve and wait for the pump to enter normal working condition before adjusting the discharge valve to the desired opening.
Before the pump stops working, the discharge valve should be closed first, and then the suction pipe valve should be closed.
Precautions for use
1. As the cooling and lubrication of the magnetic pump bearings rely on the medium being transported, it is absolutely forbidden to operate them without load, and at the same time, it is necessary to avoid idle operation caused by restarting after a power outage during operation.
If the conveyed medium contains solid particles, a filter screen should be added to the pump inlet. If it contains ferromagnetic particles A magnetic filter needs to be added. 3. The ambient temperature of the pump during use should be less than 40 ℃, and the temperature rise of the motor should not exceed 75 ℃.
5. For media that are prone to precipitation and crystallization during transportation, they should be cleaned promptly after use and the accumulated liquid in the pump should be drained.
After 500 hours of operation of the magnetic pump, the wear and inertia of the bearings and end face dynamic rings should be inspected. If the gap between the bearings and the shaft sleeve is greater than 0.5-1mm and the impeller moves axially by 1.5-2mm, the bearings and axial dynamic rings should be replaced.
Malfunctions and troubleshooting
failure mode |
cause |
Troubleshooting |
The pump is not producing water |
Reverse rotation of water pump Leakage of water pipeline Insufficient water storage in the pump chamber The voltage is too high, causing the coupling to slip during startup The suction distance is too high |
Change the motor wiring Social isolation leakage Increase storage capacity Adjust the positive voltage Lower the installation position of the pump |
Insufficient traffic |
The suction pipe diameter is too small Impeller channel blockage Head too high The speed is too low |
Replace the inlet pipe Clean the impeller Turn up the outlet valve Rated speed of Huixia |
Low head |
Excessive traffic The speed is too low |
Turn down the outlet valve Restore rated speed |
The sound is too loud |
Severe wear of the shaft Severe wear of the shaft sleeve Drive the magnetic steel cup to contact the isolation sleeve |
Replace the pump shaft Replace the shaft sleeve Dismantle the pump head and reassemble it |
Leakage of liquid |
Type 0 sealing ring damaged |
Replace the 0-type sealing ring |
Corrosion resistance of materials (for reference)
Media name |
concentration % |
polypropylene |
concentration % |
ABC |
||
25℃ |
50℃ |
20℃ |
60℃ |
|||
Sulfuric acid |
60 |
√ |
|
|
√ |
× |
Nitric acid |
25 |
√ |
|
|
√ |
O |
Hydrochloric acid |
<36 |
√ |
|
|
√ |
√ |
Fluorofluoric acid |
35 |
√ |
|
|
√ |
× |
acetic acid |
<80 |
√ |
|
|
√ |
O |
sodium hydroxide |
100 |
√ |
|
|
√ |
√ |
potassium dichromate |
25 |
√ |
|
|
√ |
√ |
bromine water |
|
√ |
|
|
O |
× |
ethanol |
|
√ |
|
|
√ |
√ |
acetone |
|
× |
|
|
O |
|
Tetrachloroethane |
|
O |
|
|
O |
× |
Freon 22 |
|
√ |
|
|
O |
O |
bleaching solution |
CL13% |
√ |
|
|
O |
O |
Electroplating solution |
|
√ |
|
|
O |
× |
Photographic liquid |
|
√ |
|
|
√ |
√ |
Media name |
concentration |
stainless steel |
concentration |
ceramics |
||
% |
25℃ |
50℃ |
% |
25℃ |
80℃ |
|
sulfuric acid |
<5 |
√ |
X |
|
V |
V |
nitric acid |
7070 |
V |
√ |
|
V |
V |
hydrochloric acid |
|
X |
|
|
V |
V |
Fluorofluoric acid |
|
X |
|
0~100 |
X |
|
acetic acid |
<20 |
√ |
√ |
|
V |
V |
sodium hydroxide |
70 |
√ |
√ |
|
0 |
X |
potassium dichromate |
40~60 |
V |
V |
10~20 |
V |
V |
bromine water |
|
0 |
|
|
V |
V |
ethanol |
|
V |
√ |
|
V |
V |
acetone |
|
V |
V |
|
V |
|
Tetrachloroethane |
50 |
V |
V |
|
V |
V |
Freon 22 |
|
V |
|
|
V |
V |
bleaching solution |
C112% |
X |
|
|
V |
V |
Electroplating solution |
|
|
|
|
V |
V |
Photographic liquid |
|
V |
|
|
V |
V |
Symbol Description: V - Excellent V - good, 0- usable But the corrosion is obvious X - severe corrosion, not applicable.