CJ400-F2 portable pump suction high concentration fluorine gas alarm features:

Can detect simultaneously1-4 types of gases, units can be freely switched

Optional units:PPM、mg/m3、Vol%、LEL%、PPHM、ppb、mg/L。

Built in pump suction measurement, integrated with water vapor and dust filters, fast response, supports long-distance sampling

Built in water vapor and dust filters prevent sensors and instruments from being damaged by water vapor and dust, and can be used in high humidity and high dust environments;

Sampling distance greater than10 meters, special gas path design, can be directly detected; Negative or positive pressure of 0.5 to 2 kilograms of gas has no effect on the measurement results.

Rich human-machine interface

2.31-inch high-definition color screen, displaying real-time concentration, alarm, time, temperature, humidity, storage, communication, battery level, charging status, concentration units

Information such as gas molecular formula and gas name; The menu interface uses high-definition simulation graphics to display the function names of each menu.

Large capacity data storage function, supporting multiple storage methods

standard configuration100000 data storage capacity, larger capacity can be customized; Support real-time storage, scheduled storage, or only storing alarm concentration data;

Support local viewing and deleting data, and can also be done throughThe USB interface uploads data to the computer, and the upper computer software analyzes, stores, and prints the data.

optionalRS485 communication.

High temperature gas detection (optional)

Optional high temperature sampling and cooling filter handle or high temperature and high humidity pretreatment system for detectionSmoke at a temperature of 400 degrees Celsius. Gas detection at higher temperatures can be customized.

Three display modes can be switched

It can measure the concentration of four gases (according to customer requirements) and display them simultaneously. It can display the concentration of a single channel gas in large font circulation and real-time curve display.

Graphical display

Reflect the trend of gas concentration changes over a period of time in the form of a curve.

Data recovery function

You can choose to partially or fully restore, eliminating the worries caused by misoperation.

Can be set to display or notZui maximum value, Zui minimum value, average value

standardUSB charging, with charging protection function, supports USB hot plugging

Can be charged with a computer or power bank, compatible with mobile phone chargers; There are overcharging, overdischarging, overvoltage Short circuit and overheating protection;5-level precise power display;

The detector can work normally during charging.

adopt4500mA high-capacity rechargeable polymer battery, capable of long-term continuous operation

High precision temperature and humidity measurement (optional)

Support real-time detection or scheduled detection

When not detecting, the pump can be turned off to extend the startup time.

Multiple alarm methods, with multi-dimensional and three-dimensional indication of alarm status during alarm

Includes sound and light alarms, vibration alarms, and visual alarms on the display screen. The types of alarms include concentration alarm, undervoltage alarm, and fault alarm.

Multiple alarm mode settings

Low alarm, high alarm, interval alarm, weighted average alarm.

Misoperation recognition function

Automatic identification and prevention of concentration calibration errors can avoid adverse effects caused by human factors.

Zero point automatic tracking, long-term use is not affected by zero drift

Multi level calibration of target points to ensure measurement linearity and accuracy

Chinese and English interface selectable

Wide operating temperature:-40~+70℃Support temperature compensation

log recording

Record calibration logs, maintenance logs, troubleshooting strategies, sensor lifespan expiration reminder, and next concentration calibration time reminder function.

Meet the requirements of intrinsic safety circuit design, anti-static, and anti electromagnetic interference

Protection level up toIP65, Waterproof, dustproof, explosion-proof, and shockproof

Technical parameters of CJ400-F2 portable pump suction high concentration fluorine gas alarm:

Gas detection

Fluorine gas F2

Testing Scope

0-1ppm、0-10ppm、0-20ppm、0-50ppm、0-200ppm

resolution

0.001ppm、0.01ppm

Detection Principle

electrochemistry

Sensor lifespan

2-3 years

Detection method

Built in pump suction, flow rate 500 milliliters per minute

display mode

2.31-inch 320X240 high-definition color screen display, operated by 5 buttons

detection accuracy

≤± 3% F.S (higher precision can be customized)

Linearity

≤±2%

Repeatability

≤±2%

alarm method

Sound and light alarm, vibration alarm, visual alarm, sound and light+vibration+visual alarm, and alarm shutdown are optional

response time

T90 ≤ 20 seconds

recovery time

≤ 30 seconds

working power supply

DC3.6V

battery capacity

3.6VDC, 4500mA large capacity rechargeable polymer battery with overcharge, overdischarge, overvoltage, overheating, and short circuit protection functions

Usage environment

Temperature -40 ℃~+70 ℃; Relative humidity ≤ 0-99% RH (built-in filter can be used in high humidity or high dust environments)

Sample gas temperature

-40 ℃~+70 ℃, equipped with a high-temperature sampling and cooling filter handle, capable of detecting smoke concentration at 400 degrees Celsius or higher

temperature measurement

-40 ℃~+120 ℃ accuracy 0.5 ℃

Humidity measurement

0-100% RH accuracy 3% RH

data storage

Standard configuration with a data capacity of 100000, supporting local viewing, deletion, or data export, and free upper computer communication software

The storage function is set to off by default and can be set to on. The storage time interval can be set arbitrarily

communication interface

USB (charging and communication), optional RS485 or RS232 communication interface

Interface language

Chinese or English can be set, default Chinese interface

Explosion proof type

intrinsically safe

Explosion-proof marking

Explosion proof Exd Ⅱ CT6

Protection level

IP65, Dustproof and splash proof

Overall dimensions

160×70×28mm(L×W×H)

weight

300g

Standard Appendix

Instruction manual, certificate of conformity, warranty card, USB charger (including data cable), high-end aluminum alloy instrument box, crocodile clip

CD (upper computer communication software), 1 humidity and dust filter

Optional accessories

Temperature and humidity measurement function, 1.2m extendable sampling handle (1-10 meter hose, standard length 1 meter)

High temperature sampling and cooling filter handle, high temperature and high humidity pretreatment system, multiple humidity and dust filters, hanging rope

Application scenarios

All occasions requiring gas concentration detection, such as petroleum, chemical, pharmaceutical, environmental protection, flue gas analysis, scientific research institutions, air treatment, etc

Online inquiry
  • Contacts
  • Company
  • Telephone
  • Email
  • WeChat
  • Verification Code
  • Message Content

Successful operation!

Successful operation!

Successful operation!