Temperature range:-70 ° C to 180 ° C
Humidity range:10% to 98% relative humidity
Integrated water storage tank20 L
Can be done through4 zero voltage switch contacts activated by MCS controller
APT.line ™ Preheating chamber technology
Programmable condensation protection for samples
beltHeated observation window with LED internal lighting
Using capacitive humidity sensors and steam humidification for humidity regulation
BINDER communication software APT-COM ™ 3 Basic versions
Fault diagnosis system using optical and sound alarms
Controller using interval programming
Independent adjustable temperature safety deviceLevel 2 (DIN 12880), equipped with optical alarm
Access hole with silicone plug50 mm, the left side
4 casters, 2 with brakes
Computer interface: Ethernet
Socket on the right side operating component230 V
pass throughDisplay on LCD color monitor
Adjustable slope function function function
Integrated continuous automatic recorder
Real Time Clock
Door heating
Alarm message when fresh water tank is short of water
A bracket made of stainless steel
Hose protection connector, including no more than1m high water supply and drainage pipes
Internal chamber made of stainless steel
PT100 temperature sensor
Insulated with polyurethane foam
Fluorine free refrigerantR-404A and R-23
Cooling through cascaded compression coolers
Finned evaporator
Top of the form
name | MKFT240-400V¹ | MKFT240-400V-C¹ |
Choose a model | standard | Equipped with transformer and frequency converter |
Item code | 9020-0286 | 9020-0297 |
measure | ||
Internal volume [L] | 228 | 228 |
Net weight of equipment (unloaded) [kg] | 415 | 415 |
Total load [kg] | 70 | 70 |
Load per partition [kg] | 30 | 30 |
The dimensions of the casing do not include additional components and connectors | ||
Net weight width [mm] | 1115 | 1115 |
Net weight at height [mm] | 1940 | 1940 |
Depth net weight [mm] | 925 | 925 |
Wall distance from rear [mm] | 230 | 230 |
Wall to side distance [mm] | 300 | 300 |
Observation window width [mm] | 508 | 508 |
Observation window height [mm] | 300 | 300 |
Internal dimensions | ||
Width [mm] | 735 | 735 |
Height [mm] | 700 | 700 |
Depth [mm] | 443 | 443 |
The number of doors | ||
Outer door | 1 | 1 |
Data related to the environment | ||
Sound pressure level [dB (A)] | 67 | 67 |
firmware | ||
Number of partitions (hours/) | 1/6 | 1/6 |
Temperature performance data | ||
Temperature range [° C] | -70…180 | -70…180 |
The temperature deviation depends on the set value [± K] | 0.2…1.8 | 0.2…1.8 |
The temperature fluctuation depends on the set value [± K] | 0.1…0.5 | 0.1…0.5 |
The average heating rate is based on IEC 60068-3-5 [K/min] | 5 | 5 |
The average cooling rate is based on IEC 60068-3-5 [K/min] | 4.2 | 4.2 |
Thermal compensation at 25 ° C [W] | 3000 | 3000 |
Climate performance data | ||
Temperature range [° C] | 10…95 | 10…95 |
The temperature fluctuation depends on the set value [± K] | 0.1…1.5 | 0.1…1.5 |
Humidity range [% relative humidity] | 10…98 | 10…98 |
The humidity fluctuation depends on the set value | ≤ 2.5 ± relative humidity | ≤ 2.5 ± relative humidity |
Condensation temperature range of condensate water [° C] | 5…94 | 5…94 |
Electric data | ||
Rated voltage [V] | 400 | 480 |
Power frequency [Hz] | 50 | 60 |
Rated power [kW] | 6.5 | 6.5 |
Equipment safety device [A] | 16 | 16 |
Phase (rated voltage) | 3~ | 3~ |
1. All technical data is only applicable toStandard specification unloaded equipment under ambient temperature of 22 ± 3 ° C and ± 10% power supply voltage fluctuation. Determine temperature data according to BINDER factory standards and DIN 12880:2007, and adapt to the recommended wall gap of 10% of the internal chamber height, width, and depth. For series devices, all data are typical averages. The technical data assumes a fan speed of 100%. We reserve the right to make technical changes.