Dongguan Saice Testing Equipment Co., Ltd
Home>Products>Battery pressure testing machine
Battery pressure testing machine
Battery pressure testing machine
Product details

Technical parameters of battery (servo) extrusion testing machine
1、 The experiment shall be conducted according to the following steps:
After fully charging the battery according to the test method specified in 4.5.1, place the battery in two planes and press it perpendicular to the direction of the electrode plates. Apply a compression force of 13.0KN ± 0.2KN between the two plates. Once the pressure reaches the maximum value, the compression test can be stopped. During the test, the battery cannot cause external short circuits.


When cylindrical batteries are compressed, their longitudinal axis is parallel to the two flat plates, while square batteries and soft pack batteries are only subjected to compression tests on the wide surface of the battery. The button type battery is subjected to compression testing with its upper and lower surfaces parallel to two flat plates. The battery placement method in the experiment is shown in Figure 2 below. Only one compression test is conducted on one sample.

电池压力试验机


2、 Main technical parameters

1. Product model

SC-DJY-50T

2. External dimensions

Approximately 2680 × 1680 × 980mm (W × H × D);

3. Control system external dimensions

Approximately 1600 × 800 × 800mm (W × H × D);

4. Test maximum battery size

500×500×500mm (W×H×D);

5. Squeezing force

50~500KN;

6. Power supply

380V±10%,50Hz±0.5HZ;
Three phase four wire system+grounding wire;
The protective grounding resistance is less than 4 Ω;
Require users to configure corresponding compressed air and independent power supply for equipment use at the installation site;

7. Total power

About 9.5KW

8. Operating current

About 18A

9. Total weight

About 2100kg

10. Noise

Measure at a distance of 1 meter from the machine and 1.2 meters from the ground in front of the machine, with a value of ≤ 75db;

Main technical parameters

1. Environmental conditions for use

The ambient temperature is 0-45 ℃ and the relative humidity is ≤ 85% R.H;
The installation site must be a flat and vibration free ground;
Keep the equipment away from heat sources and flammable and explosive substances;
The installation location should not be directly exposed to sunlight and maintain indoor air circulation;
The installation site needs to be clean and cannot be used in areas with high dust or sewage outlets;

2. Maximum squeezing force

500kN;

3. Travel itinerary

10~500mm;

3. Measurement range

0.5% to 100% of the entire process without grading;

4. Resolution

±1/500000;

5. Accuracy error of squeezing force value

± 0.5% full scale;

6. Speed

Squeezing standard configuration: adjustable from 1 to 10mm/S;

7. Displacement measurement accuracy

Actual size of battery, ± 0.5% full range;

8. Resolution

0.001;

10. Unit Conversion

kgf、lbf、N、kN;

11. Squeezing method

Vertical or horizontal;

12. Squeezing holding time

0-99 hours, 99 minutes, and 99 seconds. The testing machine can automatically terminate the test by adjusting the deformation step according to the state;

13. Experimental conditions

Professional development: combination of force, displacement, deformation, voltage, and time, data export and upload;

14. Control method

Force and displacement closed-loop loading control, test spectrum editing and program control;

15Voltage acquisition

1. Test range: Single channel 0-10V;

2. Number of channels: 5 channels;

3. Test accuracy: ± 0.5% of full scale;

4. Data collection frequency: ≥ 30 times/second;

5. Resolution: 0.1mv;

16temperature collection

1. Test range: 0-300 degrees Celsius;

2. Number of channels: 5 channels;

3. Test accuracy: ± 0.3% of full scale;

4. Data collection frequency: ≥ 30 times/second;

5. Resolution: 0.1;

17. Drive mode

Hydraulic servo drive;

18. Meet the testing standards

GB/T31486-2015 Requirements and Test Methods for Electrical Performance of Power Batteries
GB/T31485-2015 Safety requirements and test methods for power batteries
GB/T31484-2015 Cycle Life Requirements and Test Methods for Power Batteries
GB/T31467.1-2015 Lithium ion power battery packs and systems
GB/T18332.2-2001 Nickel metal hydride batteries for electric road vehicles;
QC/T743 Lithium ion batteries for electric vehicles;
QC/T744 Metal hydride nickel battery for electric vehicles;
International standards for automotive power batteries (ISO, IEC, SAE, JEVA, CEN, etc.), international standard associations, and testing specifications for major projects related to electric vehicles under the 863 Program;
QB/T2947.3-2008 Electric Vehicle Batteries and Chargers Part 3;
DB12/T246-2005 Test Standard for Lithium ion Batteries of Electric Bicycles;
GB19521.1-2005 Safety Specification for Inspection of Dangerous Characteristics of Lithium Battery Pack Dangerous Goods;