Technical parameters of battery (servo) extrusion testing machine
1、 The experiment shall be conducted according to the following steps:
After fully charging the battery according to the test method specified in 4.5.1, place the battery in two planes and press it perpendicular to the direction of the electrode plates. Apply a compression force of 13.0KN ± 0.2KN between the two plates. Once the pressure reaches the maximum value, the compression test can be stopped. During the test, the battery cannot cause external short circuits.
When cylindrical batteries are compressed, their longitudinal axis is parallel to the two flat plates, while square batteries and soft pack batteries are only subjected to compression tests on the wide surface of the battery. The button type battery is subjected to compression testing with its upper and lower surfaces parallel to two flat plates. The battery placement method in the experiment is shown in Figure 2 below. Only one compression test is conducted on one sample.
2、 Main technical parameters
1. Product model |
SC-DJY-50T |
2. External dimensions |
Approximately 2680 × 1680 × 980mm (W × H × D); |
3. Control system external dimensions |
Approximately 1600 × 800 × 800mm (W × H × D); |
4. Test maximum battery size |
500×500×500mm (W×H×D); |
5. Squeezing force |
50~500KN; |
6. Power supply |
380V±10%,50Hz±0.5HZ; |
7. Total power |
About 9.5KW |
8. Operating current |
About 18A |
9. Total weight |
About 2100kg |
10. Noise |
Measure at a distance of 1 meter from the machine and 1.2 meters from the ground in front of the machine, with a value of ≤ 75db; |
Main technical parameters |
|
1. Environmental conditions for use |
The ambient temperature is 0-45 ℃ and the relative humidity is ≤ 85% R.H; |
2. Maximum squeezing force |
500kN; |
3. Travel itinerary |
10~500mm; |
3. Measurement range |
0.5% to 100% of the entire process without grading; |
4. Resolution |
±1/500000; |
5. Accuracy error of squeezing force value |
± 0.5% full scale; |
6. Speed |
Squeezing standard configuration: adjustable from 1 to 10mm/S; |
7. Displacement measurement accuracy |
Actual size of battery, ± 0.5% full range; |
8. Resolution |
0.001; |
10. Unit Conversion |
kgf、lbf、N、kN; |
11. Squeezing method |
Vertical or horizontal; |
12. Squeezing holding time |
0-99 hours, 99 minutes, and 99 seconds. The testing machine can automatically terminate the test by adjusting the deformation step according to the state; |
13. Experimental conditions |
Professional development: combination of force, displacement, deformation, voltage, and time, data export and upload; |
14. Control method |
Force and displacement closed-loop loading control, test spectrum editing and program control; |
15、Voltage acquisition |
1. Test range: Single channel 0-10V; |
|
2. Number of channels: 5 channels; |
|
3. Test accuracy: ± 0.5% of full scale; |
|
4. Data collection frequency: ≥ 30 times/second; |
|
5. Resolution: 0.1mv; |
16、temperature collection |
1. Test range: 0-300 degrees Celsius; |
|
2. Number of channels: 5 channels; |
|
3. Test accuracy: ± 0.3% of full scale; |
|
4. Data collection frequency: ≥ 30 times/second; |
|
5. Resolution: 0.1; |
17. Drive mode |
Hydraulic servo drive; |
18. Meet the testing standards |
GB/T31486-2015 Requirements and Test Methods for Electrical Performance of Power Batteries |