Technical parameters of power battery thermal abuse (thermal shock) test chamber
1、 The heating test shall be conducted according to the following steps:
1. Safety test of single battery
Charge the individual battery according to the method in 6.1.3.
Place the individual battery in the temperature chamber:
——For lithium-ion batteries, the temperature chamber rises from room temperature to 130 ℃± 2 ℃ at a rate of 5 ℃/min and maintains this temperature for 30 minutes before stopping heating;
——For nickel metal hydride batteries, the temperature chamber rises from room temperature to 85 ℃± 2 ℃ at a rate of 5 ℃/min and maintains this temperature for 2 hours before stopping heating.

c. Observe for 1 hour.
Battery module safety test
The heating test shall be conducted according to the following steps:;
Charge the battery module according to the method in 6.1.4;
For lithium-ion batteries, the temperature chamber rises from room temperature to 130 ℃± 2 ℃ at a rate of 5 ℃/min and maintains this temperature for 30 minutes before stopping heating;
1. Temperature range: normal temperature -200 degrees (adjustable)
2. Temperature display: digital display
3. Temperature uniformity: ± 2 degrees
4. Heating time: 5 degrees per minute
5. Timer: 0-9999H (can be set and displayed)
6. Inner box dimensions (width x depth x height): approximately 400 x 400 x 500mm
7. Box material: Inner box made of stainless steel, outer box made of cold-rolled steel plate treated with baking paint
8. Insulation material: high-efficiency compressed insulation cotton
9. Supply air circulation system: convective supply air circulation system
10. Protection device: over temperature alarm, overload protection
11. Equipment dimensions (length x width x height): approximately 650 x 530 x 920mm
12. Working power supply: AC220V, 50Hz
You have not filled in any product parameters or pictures yet. Please provide more details to make the page more beautiful.